Teac RD-101T 4 Channel PCM Data Recorder

Teac RD-101T 4 Channel PCM Data Recorder
Manufacturer: TEAC
Call for pricing
Teac RD-101T 4 Channel PCM Data Recorder

 

Teac RD-101T 4 Channel PCM Data Recorder

Rent me for $300 a month

with options

  • TZ-313FA Anti aliasing Filter
  • Uses Standard DAT Tapes

High-quality data (accuracy)

   The quadruple oversampling digital filter is used as the output stage in the multiplex PCM recording method. The signal-to-noise ratio is 70 dB. The frequency characteristic flatness is +0.5 dB, -1 dB. The phase difference between channels is 5° (fmax).

Multi-channels and wide band

   The RD-101T uses a 2-channel/4-channel switching system. The band for 2-channel recording is 20 kHz and the band for 4-channel recording is 10 kHz.

Small and compact

   The data recorder is approximately 306 mm wide x 100 mm high x 307 mm deep, and weighs approximately seven kilograms. The data recorder is therefore very portable.

Long recording time

   When a 120 tape (approximately 60 m) is used, data can be recorded continuously for two hours.

Three power supplies

   Operates on either AC input of 90-130 (180-250) volts, DC input of 11-30 volts, which are provided normally, and an optional rechargeable battery unit. The battery unit can be incorporated by mounting it on the data recorder. Since the battery charge function is built into the data recorder and protection for battery over-discharging is provided, the RD-101T can be used both indoors and outdoors.

Easy operation (condition setting is unnecessary)

   The input range is fixed to eliminate the need for complicated range setting. The purpose of this function is to approach the absolute value recording by making the input and output voltages equal:

Memo sound channel

   In addition to the data channels, a channel used only for voice recording and reproduction is provided. Since the microphone built into the data recorder is provided normally for recording, environmental sounds can always be recorded during measurement.

Time code recording channel

   In addition to the data channels, a channel used only for recording and reproduction of time codes is built in. The year, month, day, hours, minutes, and seconds of the built-in clock with perpetual calendar are automatically recorded. Since the time code is always automatically recorded, it can be used to confirm the recording time of measurement data on the display.

Data number (ID number) recording channel

   In addition to the data channels, a channel used only for recording and reproduction of ID numbers is built in. The ID number of the recorded data is automatically recorded. The ID number is incremented by one each time recording starts or the EVENT button is pressed.

High-speed search

   The recorded ID number can be searched for at high speed during reproduction. The search is performed both in the forward and reverse directions. When the target ID number is found, the target data is reproduced from the beginning.
Pressing the PAUSE button during search causes the tape to pause at the beginning of the data when the search ends.  

US-Instrument.com