JDSU/Acterna/TTC Fireberd 4000 Communications Analyzer

JDSU/Acterna/TTC Fireberd 4000 Communications Analyzer
Manufacturer: JDSU/Acterna/TTC /WG
Call for pricing
JDSU/Acterna/TTC Fireberd 4000 Communications Analyzer

 

JDSU/Acterna/TTC Fireberd 4000 Communications Analyzer

Rent me for $400 a month

Operates at rates of 50b/s to 15MB/s for testing digital communications circuits

   The JDSU/Acterna/TTC Fireberd 4000 will simultaneously measure bit errors, code violations, frame errors, block errors, pattern slips, and performs signal analysis. RS-232 and MIL-188-114 interfaces are standard.

Description

   The FIREBERD 4000 Communications Analyzer is a flexible, cost-effective instrument that tests digital circuits and equipment. Combining convenience and reliable performance, the FIREBERD 4000 is ideally suited for a wide variety of test applications.

   Operating at rates from 50 b/s to 15 Mb/s, the FIREBERD 4000 provides a high degree of flexibility for testing G.703, T-Carrier, and DDS circuits, evaluating equipment performance, or performing long-term or unattended testing. THe instrument features a range of standard data rates, plus the ability to operate at non-standard data rates when the optional frequency synthesize is installed.

Specifications

Operating Ranges

  • Synchronous: 50 b/s to 15 Mb/s.
  • Asynchronous: 50 b/s to 20 kb/s (Internal RS-232/V.24 and MIL-188C interfaces only).

Generator Timing

  • Clock Sources: Fixed internal frequencies, data interface and external BNC.
  • Internal Clock Frequencies: 300 Hz, 1.2 kHz, 2.4 kHz, 4.8 kHz, 9.6 kHz, 19.2 kHz, 56 kHz, 64 kHz, 128 kHz, 256 kHz, 512 kHz, 1544 kHz, and 2048 kHz +/- 5ppm.

Data Generator

  • Fixed Patterns: Mar, Space, 1:1, 1:7, 3-in-24, and a user-programmable pattern of 3 to 24 bits in length.
  • Pseudorandom Patterns: 63, 511, 2047, 215-1, 220-1, 223-1, QRSS.
  • Messages: Non Programmable: standard FOX asynchronous message in four different code levels; Programmable: three asynchronous messages up to 2000 bytes in length.
  • Asynchronous Setup: Odd, none, or even parity; 5- to 8-bit code levels; 1, 1.5, or 2 stop bits.
  • Error Insertion: Single error or fixed 10-3 rate in generated data only.

Error Analysis Receiver

  • Sync Loss Thresholds: User-Selectable 100/21, 250/21, and 20,000/100,000 errors/total bits.
  • Block Lengths: 102 to 106 bits, or pattern lengths.

Signal Analysis

  • Frequency Measurement Range: 50 Hz to 16 MHz.
  • Accuracy: +/- 5ppm

Test Results

  • Summary Results (Non-Zero results only): Bit errors, bipolar violations (BPVs), character errors, code errors, cylic redundancy check (CRC) errors, block errors, frame errors, frame alignmen signal (FAS) errors, pattern slips, pattern loss.
  • Error Results: Average bit error rate, average block error rate, bit errors, bit error rate, blocks, block errors, character errors, pattern loss, pattern slips. 

US-Instrument.com