JDSU/Acterna/TTC 209OSP DS1 T-Carrier Analyzer

JDSU/Acterna/TTC 209OSP DS1 T-Carrier Analyzer
Manufacturer: JDSU/Acterna/TTC /WG
$0.00

 

JDSU/Acterna/TTC 209OSP DS1 T-Carrier Analyzer

 

JDSU/Acterna/TTC 209OSP DS1 T-Carrier Analyzer 

with options

  • 209OSP-1 - DC Measurements
  • 209OSP-2 - TDR Measurements
  • 209OSP-3 - Channel Monitor
  • 209OSP-4 - Advanced Stress Patterns
  • 209OSP-5 - Enhanced ESF
  • 209OSP-6 - Smart Loopback/Command Codes
  • 209OSP-7 - Fractional T1
  • 209OSP-8 - HDSL/ISDN/DDS Measurements

   Outside plant technicians have to perform a number of tasks: install apparatus cases and splice cables; locate and repair span faults such as bridged taps, load coils, shorts, opens; and verify that cable meets carrier requirements prior to Central Office or Customer Premise equipment installations. With this multitude of tasks, outside plant technicians need a solution that enables them to perform extensive physical layer testing in an all inclusive, easy-to-use test set. The T-BERD Outside Plant Tester (209OSP) is a complete tool that meets the exclusive testing requirements of the outside plant technicians. It combines copper prequalification features (TDR and DC measurements) with service turn-up and troubleshooting features for T1/FT1/HDSL/ISDN /DDS technologies. The combination of copper analyzer and digital loop tester features makes the T-BERD Outside Plant Tester the most flexible, all-in- one solution for outside plant testing

Specifications

  • Input and Output Connectors: WECO 310, 15-pin D, T1 Repeater Port, 8 pin RS-232, RJ48
  • Input Impedance:
    • Bridge: 21 ohm with ALBO
    • Term: 100 ohm with ALBO
    • DSX-MON: 100 ohm with AGC
  • Receive Level
    • Bridge or term: +6 dBdsx to -35 dBdsx (T1), +3 dBdsx to -6 dBdsx (T1C)
    • DSX-MON: +6 dBdsx to -24 dBdsx (T1), +3 dBdsx to -24 dBdsx (T1C)
  • Level Measurement:
    • +6.0 dBdsx to -40 dBdsx
    • +6 to -6, 0.1 dB resolution
    • -6 to -40, 0.5 dB resolution
  • Frequency Measurement: 1 Hz resolutions; 5 ppm accuracy
  • Transmit Timing Sources: Internal Clock, Recovered Clock
  • Line Codes: AMI, B8ZS
  • Loopback Codes: CSU, CSU Line (ESF), CSU Payload (ESF), NIU (FAC1, FAC2, FAC3), NIU Network (ESF), Programmable (3 to 8 bits), Intelligent Repeaters, HDSL End-Equipment
  • DC Measurements:
    • Resistance: 10 ohm to 10 Mohm
    • Volts DC: 0.5 to 400 VDC
    • Simplex Current: 0 to 200 mA
  • TDR Measurements:
    • Pulse Amplitude: 10.0 V p-p
    • Measurement Range: 50 to 10,500 ft
  • HDSL Measurements:
    • Loop Loss: 0.0 dB to 40.0 db
    • Accuracy: ±0.5 dB
    • Resolution: 0.1 dB
    • Loop Length: 100 to 20,000 ft
    • Capacitance: 1500 pF to 323,500 pF
    • Power: -40.0 to +13.0 dB