with options

  • 211-1 G.821 Performance
  • 211-2 Jitter Spectrum
  • 211-3 LUP
  • 211-4 ESF Superframe
  • Lid option T1 Channel Monitor Model 40849

   The JDSU/Acterna/TTC 211 Portable T1 Line Analyzer ideal for installation and maintanence of T1 transmission systems, offering over 50 simultaneous T-Carrier measurements. Some features of the 211include CSU/NIU emulation, automated Bridgtap & Multipat tests. This unit is an upgrade from the Acterna/TTC 209 series.

T-Carrier Analyzer Features

  •  Automatic configuration and results summary
  • Automated sequences of test patterns for one-step circuit qualification and stress tests
  • Pulse shape analysis, signal level and frequency, simplex current, and wander measurements
  • Out-of-band ESF loop codes standard
  • Wideband and high band jitter measurement

Specifications

  • Input and Output Connectors: Bantam, WECO 310, 15-pin D, BNC
  • Input Impedance: Bridge: > 21 ohms with ALBO, Term: 100 ohms with ALBO, DSX-MON: 100 ohms with AGC Receive Level
  • Bridge or term: +6 dBdsx to -35 dBdsx (T1)  +3 dBdsx to -6 dBdsx (T1C)
  • DSX-MON: +6 dBdsx to -24 dBdsx (T1), +3 dBdsx to -24 dBdsx (T1C) Level Measurement: +6 dBdsx to -40 dBdsx; +6 to -6, 0.1 dB resolution; -6 to -40, 0.5 dB resolution
  • Frequency Measurement: 1 Hz resolutions; 5 ppm accuracy
  • Transmit Timing Sources: Internal Clock, External Clock, Reference Clock, Recovered Clock Line
  • Codes: AMI, B8ZS Loopback Codes: CSU, CSU Line (ESF)
  • CSU Payload (ESF), NIU (FAC1, FAC2, FAC3)
  • NIU Network (ESF), Programmable (3 to 8 bits)
  • Intelligent Repeaters Pulse Masks: CB 119 (ANSI T1.102), ANSI T1.403-1989
  • Wander Measurement: +99999 UI, 1 UI resolution
  • Power Requirements: 115 VAC ±10%, 50 to 60 Hz