Hipotronics 100HVT The 100 HVT Series AC test sets are specifically designed to perform quick and accurate AC dielectric tests. The 100 HVT has a maximum output of 100 kV at 50 mA or 50 kV at 100 mA. This test set can be used for testing bucket trucks and aerial platforms, hot sticks, blankets, ropes or any other high voltage AC test requirement. They are particularly suitable for meeting test procedures of the ANSI/SIA A92.2 1990 specification applied to the insulating boom of work platforms and bucket trucks. A triple range current meter enables low current readings of 0 to 1/10/100 mA on the 100 HVT. A triple range voltmeter is connected directly across the output for maximum accuracy. The 100 HVT has a 50 kV tap that is used for bucket liner testing and other low voltage, high current test requirements. Features Continuously adjustable output from zero to full voltage Compact design Single end grounded high voltage test transformer Separate guard and return Triple range current meter Triple range voltmeter Hand cart mounted Zero start interlock External interlock provision Input power circuit breaker Fast acting circuit breaker 50 kV tap for bucket liner testing. Benefits Test to ANSI/SIA A92.2 1990 specifications Ideal for any high voltage AC insulation test requirements Portable, for use in the field Safe and easy operation Low leakage current measurements Guard circuit eliminates stray leakage current Applications Aerial platform hipoting Bucket truck hipoting Hot stick testing Rotating machinery testing Any high voltage AC test requirement (within current limitations) For a drawing of the front control panel layout follow this link Specifications Input Voltage 120V, 60/60 Hz - Model number suffix A 220V, 50 Hz - Model number suffix B Output 100 kV @ 50 mA = 5 kVA/50 kV @ 100 ma = 5 kVA Current Meter Triple range 0 to 1/10/100 mA Voltmeter Triple range 0 to 25.50.100 kV AC Duty Cycle 5 minutes on, 15 minutes off, repeated 6 times, then off for 2 hours Output Termination High Voltage Toroid Meter Accuracy ±2% of Full Range Distortion Less than 5% of sinusoidial wave Cables 25' (7.6 meters) Controller to HV Tank with Plug Connection (2) 25' Shielded Cable for Return and Voltmeter (2) 25' Guard/Ground Cable 10' (3 meters) Input Power Cable Dimensions 17.4" W x 14.5" D x 31.9" H (441 x 368 x 810 mm) Net Weight HV Section 135 lb (61 kg) Controls 62 lb (28 kg) Complete Unit 240 lb (109 kg) Ship Weight 306 lb (139 kg)

US-Instrument.com