Clark Hess Model 5000 Phase Standard

Clark Hess Model 5000 Phase Standard
Manufacturer: Clark-Hess
Call for pricing

 

Clark Hess Model 5000 Phase Standard

 

Clark Hess Model 5000 Phase Standard

Rent me for $300 a month

Clark Hess Model 5000 Phase Standard. The world standard for Phase Measurement. Difficult to locate on of these.

User Friendly

   Only single keystrokes on clearly labeled keys are required to enter all of the parameters into the Model 5000 Phase Standard. A large bright display shows Phase, Frequency and both output Amplitudes at all times.

Extremely Versatile

   The combination of excellent phase accuracy, excellent amplitude accuracy and low distortion from each channel make the Model 5000 Phase Standard ideal for calibrating Phase Meters, Vector Voltmeters, Broadband Wattmeters and Power Analyzers, Resolvers and other Phase Sensitive Instruments.

Continuous Phase Calibration

   The Model 5000 Phase Standard contains an Autozero function which measures the output phase at ±90° and makes an internal correction to remove any phase errors between the two output channels. The Autozero operation, which takes less than 0.25 sec., is activated automatically each time an amplitude or frequency is changed. It may also be activated manually.

Digital Precision

   Both output sinewaves are generated digitally with the result that the basic parameters of Phase and Frequency require no adjustments to maintain their superior accuracy. Only the output amplitudes are adjustable.

Load Imunity

   The extremely low output impedance of the Model 5000 Phase Standard coupled with its ability to Autozero with an external load in place, makes the phase accuracy of the instrument completely insensitive to loading.

Extensive Self Test

   The Model 5000 Phase Standard has an internal SELF TEST capability which checks the output frequency for all frequency ranges, checks all of the digital sine wave generation circuitry, checks the output levels of all amplitude ranges for both channels and checks the Autozero function.

Easy to Calibrate

   The complete set of specifications of the Model 5000 Phase Standard may be checked with an accurate ac/dc (true rms) Multimeter, an accurate Frequency counter, a good Distortion Analyzer and the Clarke-Hess Model 5002 Phase Verification Bridge Set. This completely passive bridge set may be sent either to Clarke-Hess or directly to NIST for annual recertification.

Automated Adjustments

   Many of the adjustments for the internal potentiometers in the Model 5000 Phase Standard are included in an internal calibration routine. If adjustment is required during annual recertification, the operator just turns the "pot" until a value indicated on the display is obtained. The ability to operate the instrument over the IEEE-488 interface makes other adjustments equally straight forward.

Specifications

  • Phase Angle Range: 0.000° to ±999.999° Resolution: 0.001° from 1Hz to 100kHz
  • Output Frequency Range: 1Hz to 100kHz Resolution: 1Hz from 1Hz to 6250Hz, 10Hz from 6250Hz to 51kHz, 20Hz from 51 kHz to 100kHz
  • Output Amplitude Range: 100mV rms to 100.0V rms