Enhanced AC/DC Hypot with Ground Continuity Test Set

The most common applications of the dielectric-withstand (Hipot) test are:

  • Design (performance) Testing - Determining design adequacy to meet service conditions.
  • Product Line Testing - Detecting defects in material or workmanship during processing.
  • Acceptance Testing - Proving minimum insulation requirements of purchased parts.
  • Repair Service Testing - Determine reliability and safety of equipment repairs.

Features

  • Output Range:
    • AC: 0 - 5 kV, 2V / step, 12 mA
    • DC: 0 - 6 kV, 2V / step, 5 mA
    • Regulation: ± (1% of output + 5V)
  • Output Frequency: Sinewave, Distortion: <2% THD
  • Output Resolution: 10 volt/step
  • Output Accuracy: ±2% of setting + 5 volts
  • Leakage Current: 12 mA 
  • Adjustable High and Low Limits ( 0.01 mA resolution )
  • Timer: 0.0 - 999.9 seconds
  • Ground Continuity Current: DC 0.1A ± 0.01A, fixed
  • Input Voltage: 120/230 V AC, ± 15 %, Single Phase, 47 - 63 Hz
  • Weight: 20 lbs (9.07 kg)
RAMP TIME SETTING 0.2 - 999.9 seconds in 0.1 second increments 0 ramp setting = 0.1 seconds fixed

METERING Voltmeter (3 digits)

  • Range: AC 0.00 - 5.00 KV
  • DC 0.00 - 6.00 KV
  • Resolution: .01 KV
  • Accuracy: ± (2% of reading + 10 V)
AMMETER (4 digits)
  • Range: AC 0.10 - 12.00 mA
  • DC 0.02 - 5.00 mA
  • Resolution: .01 mA
  • Accuracy: ± (2% of reading + 0.02 mA)
TIMER DISPLAY Range: 0.0 - 999.9 seconds
  • Resolution: 0.1 second
  • Accuracy: ± (0.1% of reading + 0.05 seconds)
GROUND CONTINUITY CHECK
  • Current: DC 0.1A ± 0.01A, fixed
  • Max. ground resistance: 1 ohm ± 0.1 ohm, fixed
REMOTE CONTROL AND SIGNAL OUTPUT

The following input and output signals are provided through the 9 pin D type connector:
  • Inputs: test and reset
  • Outputs: pass, fail, and test in process