Agilent/HP N1627A Time Domain Reflectometer Module
Agilent/HP N1627A Time Domain Reflectometer Module
The Agilent/HP N1627A Time Domain Reflectometer module provides highly accurate, general purpose metallic cable TDR capability to the Service Advisor family. Its easily used for short and long distance applications on any type of cable network including twisted pair, coaxial, and LAN.
The Agilent/HP 1627A Metallic Time Domain Reflectometer (MTDR) Module plugs into the N1610A Service Advisor Tablet to provide portable time domain reflectometer (TDR) testing capability. The MTDR Module also plugs into the N1700A Service Advisor undercradle to support operation with the Agilent J2300C Internet Advisor.
Output Connectors
- Balanced: dual bantams
- Unbalanced: BNC
Output Impedance
- Balanced: 100 ohms
- Unbalanced: 50 Ohms
Measurement Modes
- Unbalanced: transmit/receive on single BNC port
- Balanced: single port transmit/receive; dual port transmit/receive
Maximum Range
- 20,000 m at any VoP, depending on cable type and condition
Distance Accuracy
- 0.1 % ±200 ps ± VoP uncertainty ± cursor resolution
Cursor Resolution
US-Instrument.com