Acterna/WG EMR-20 Portable EM Radiation Meter

Acterna/WG EMR-20 Portable EM Radiation Meter
Manufacturer: JDSU/Acterna/TTC /WG
Call for pricing

 

Acterna/WG EMR-20 Portable EM Radiation Meter
Acterna/WG EMR-20 Portable EM Radiation Meter

Rent me for $150 a month

100 kHz to 3 Ghz for isotropic measurement of electrical fields

   The Acterna/WG EMR-20  provides precise measurement of electrical field strength, making it ideal for safety monitoring in areas where high levels of radiation are likely and for EMC applications.

  • true triaxial measurement
  • optical interface for automated calibration and transfer of measured data
  • high measurement accuracy due to automatic offset adjustment even during field exposure
  • very easy to use
  • shockproof, dust proof, and splash proof
  • built-in stand and tripod bush

Applications

      Precision measurement of electric field strength for personal safety at work where high radiation levels are present, and for applications involving electromagnetic compatibility (EMC), such as:

  • Service work on transmitting equipment
  • Working with plastic welding machines
  • Operating diathermy equipment and other medical instruments producing short-wave radiation
  • Drying equipment in the tanning and timber industries
  • Field strength measurements in TEM cells and absorber chambers
Radiation measurement
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . electrical field (E)
Frequency range . . . . . . . . . . . . . . . . . . . . . . 100 kHz to 3 GHz
Specified measurement principle . digital triaxial measurement
Directional pattern . . . . . . . . . . . . . . . isotropic, 3-dimensional
Measurement range
CW signals (f4300 kHz) . . . . . . . . . . . . . . 0.6 V/mto 800 V/m
true RMS . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.6 V/mto 20 V/m
Range selection . . . . . . . . . . . . . . one single continuous range with 462 dB dynamic
Display resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.01 V/m
Absolute error at 27.5 V/m and 27.12 MHz . . . . . . . . . . +1 dB
Linearity referred to 27.5 V/m and 27.12 MHz
from 0.6 V/m to 1.25 V/m . . . . . . . . . . . . . . . . . . . . . . +3 dB
from 1.25 V/m to 2.5 V/m . . . . . . . . . . . . . . . . . . . . . . +1 dB
from2.5 V/mto 400 V/m . . . . . . . . . . . . . . . . . . . . . +0.5 dB
from400 V/mto 800 V/m . . . . . . . . . . . . . . . . . . . . +0.7 dB
Frequency response:
EMR-20C/-30C with consideration of CAL factor and inclusive of calibration accuracy
from100 kHz to 100MHz . . . . . . . . . . . . . . . . . . . +0.45 dB
from100MHz to 3 GHz . . . . . . . . . . . . . . . . . . . . . .+1.4 dB

US-Instrument.com