KeyTek ECAT Model EP61 and EP62 Power Quality Falure Modules

KeyTek ECAT Model EP61 and EP62 Power Quality Falure Modules
Manufacturer: Keytek
Call for pricing
KeyTek ECAT® Model EP61 and EP62 Power Quality Falure Modules

 

KeyTek ECAT® Model EP61 and EP62 Power Quality Falure Modules

   Plug-in modules provide swells, dips and interrupts on AC power mains in compliance with, and exceeding the requirements of IEC 621-4-11 Edition 2. Model EP61 for single-phase AC lines to 240 RMS, 16A; Model EP62 for single-phase AC lines to 240 RMS, 32A

AC INPUTS/OUTPUTS

    Input Voltage for 100%

  • 50 to 240V at 50Hz and to 277V at 60Hz
  • Output Voltages on the Selected Phase

  • 0% (open or short), 40%, 50%, 70%, 80%, 90%, 100%, 110%, 120% and 150%
  • EP61 Output Current

  • 16A at 250V; 20A at 125V*
  • EP62 Output Current

  • 32A at 250V; 30A at 125V*
  • Inrush Current

  • >250A at 120V; >500A at 220-240V
  • Event Duration

  • from 0.03 cycle (10°) to 500 minutes; maximum 12 events per cycle
  • Switching Times

  • 1-5µs into a 100 ohm load
  • Overshoot

  • <5%
  • Undershoot

  • <5%
  • MEASUREMENTS

    rms Voltage

  • 0-300V, 0.5% of range + 1% of reading
  • rms Current

  • 0-40A, 0.5% of range + 1% of reading
  • Peak Current

  • 0-21A, 1% of range + 5% of reading
  • Inrush Current Qualification

  • Internal, built-in circuit according to IEC 621-4-11. Automatically measures peak inrush current at 90° and 270°. Peak values are reported via the control software.
  • Minimum System Requirements:

  • E100 series control center

*The actual AC mains voltage and current limit is based on the mains connector selected.