Tektronix
|
|
Tektronix P6101A
|
Contact Sales
|
|
|
Tektronix P6101A
|
| |
| |
Tektronix
|
|
Tektronix P6451
|
Contact Sales
|
|
|
Tektronix P6451
DESCRIPTION:
The P6451 Data Acquisition Probe is a 8-Channel probe for use with 7D01, 7D01F, 7D01F2 & 7D02 Option 01.
|
| |
| |
Tektronix
|
|
Tektronix P6470
|
Contact Sales
|
|
|
New Page 1
Tektronix P6470
Description:
The P6434 is a 34 channel probe with quick connect/disconnect and a positive latching mechanism to ensure a secure, reliable connection.
An optional low-profile adapter for low-clearance applications is also available. This probe is recommended for all high-density applications. The compression to P6434 adapter allows P6434 Mictor Probes to connect to the compression footprint. Probe Cable Length - 1.5 m (5ft.).
|
| |
| |
Tektronix
|
A6302
|
Tektronix A6302 Current Probe
|
Contact Sales
|
|
|
Tektronix A6302 20 Amp Current Probe
Tektronix A6302 20 Amp Current Probe
Rent me for $100 a month
The Tektronix A6302 is a DC to 50 MHz current probe
designed for use with the AM503 family of current probe amplifiers and with the
11A16 plug-in. With the AM503 family, the A6302 can measure currents to 20 A (DC
+ peak AC), and up to 50 A peak current (while not exceeding the amp-second
rating). With the 11A16 plug-in, the A6302 can measure currents to 10.5 A.
|
| |
| |
Tektronix
|
|
Tektronix P6009
|
Contact Sales
|
|
|
Tektronix P6009
Description:
The P6009 is a
low-input-capacitance, high-voltage passive probe with a
signal attenuation of 100X. It is designed for use with wide-band,
real-time oscilloscopes, and may be used with any plug-in unit or
oscilloscope having a 1-megohm input resistance and an input
capacitance of 15 to 47 pf.
The
probe is available with a standard BNC output connector or with a
special BNC connector for readout oscilloscopes. The readout version is
recommended for use only with a TEKTRONIX 7000-Series Mainframe (with
readout) or the TEKTRONIX 485 Oscilloscope. When used with these
instruments, the special connector on the probe causes the oscilloscope
readout to switch, automatically correcting for attenuation of the
probe.
The P6009 consists of a
probe-body assembly, a
9-foot cable, and a compensating box assembly with a BNC connector. The
compensating box houses adjustments for optimizing the high-frequency
response of the probe.
|
| |
| |
AEMC
|
193-36
|
AEMC 6500 Amp Flexible Current Probe
|
Contact Sales
|
|
|
AEMC 6500 Amp Flexible Current Probe
AEMC 6500 Amp Flexible Current Probe
For the AEMC 3945 Power Quality
Analyzer
Rent me for $150 a month
Set of three color-coded 36" Flexible 6500A AmpFlex Sensors Model 193-36 for
use with AEMC 3945 PowerPad Power Quality Instruments. Extends the range of
measurement to 6500 amps for those big jobs. Flexible design allows easy
placement in confined spaces. These probes cover the frequency range of 40-69
hertz.
|
| |
| |
AEMC
|
MR411
|
AEMC MR411 Dual Range 600/60 Amp AC/DC Current Probe
|
Contact Sales
|
|
|
AEMC MR411 Dual Range 600/60 Amp AC/DC Current Probe
AEMC MR411 Dual Range 600/60 Amp AC/DC Current
Probe
The MR411 is a general purpose 600ADC current probe designed for use
with DMMs, loggers or oscilloscopes and other instruments that have voltage
inputs. The MR411 offers dual ranges of 60 and 600ADC. The
MR411 has an integral 5 ft (1.5m) lead terminated by shrouded banana plugs.
Features
Measurement range of 600ADC
Conforms to EN 61010, 600V Cat. III
Low phase shift for power measurements
Designed for DMMs, recorders, oscilloscopes, power and harmonic meters
Applications
DC motors
Batteries
Automobile engine testing
Power measuring quality analysis
Power load monitoring
|
| |
| |
AEMC
|
SL-261
|
AEMC SL-261 AC/DC Current Probe
|
Contact Sales
|
|
|
AEMC SL-261 AC/DC Current Probe
AEMC SL-261 AC/DC Current Probe
Rent me for $50 a month
The Model SL261 is a portable 100A peak current probe with
insulated BNC output cable that can accurately measure AC or DC current
waveforms. The unit has proportional mV output for direct readings on
oscilloscopes. Three position slide switch on handle selects ranges and ON/OFF.
These work with any device with a BNC input. They are a perfect match for the
Sentinel Current Logger Model SDL A402 four-channel datalogger.
Features
Oscilloscope current probe for applications in industrial and power
environments
Analyze, measure and accurately display distorted current waveforms and
harmonics
Current range from 100mA to 100AAC/DC
Direct BNC connection to scope
Jaw designed for easy maneuvering in crowded spaces
Applications
Oscilloscope applications in industrial or power environments
Analysis and measurement of distorted current waveforms and harmonics
The Model SL261 is designed for AC/DC current measurement capabilities using Hall effect technology. It measures from a few mA to over 100Amps. The "screw driver" shape, with its narrow elongated prod, was chosen to
permit probing in crowded cable bundles, or measuring in tight areas such as on
circuit boards, motor controllers and automotive circuitry. The electronics and
batteries are self-contained in the handles. It is an excellent companion to
DMM's, recorders and loggers, oscilloscopes and waveform displaying instruments.
Low phase shift also insures reliable power and power quality measurements. The
Model SL261 probe is designed for current measuring and displaying on
Oscilloscopes. AC + DC output signals proportional to the total current are
provided for True RMS measurements.
|
| |
| |
Agilent / HP
|
1141A
|
Agilent 1141A Differential Probe
|
$995.00
|
|
|
Agilent 1141A Differential
Probe
The Agilent 1141A is a 1X FET differential probe with 200 MHz bandwidth
and 3000:1 CMRR (Common Mode Rejection Ratio) at 1 MHz. The probe has
an input resistance of 1 MÙ and low input capacitance of 7 pF,
to minimize circuit loading. The Agilent 1141A 200 MHz Differential
Probe must be used with the Agilent 1142A Probe Control and Power
Module. It can be connected to any instrument with 50 ohm inputs. An
external 50 ohm termination can also be used with high impedance
inputs. Features Superior tolerance to ESD Low dc thermal drift
±200 V (dc + peak ac) maximum allowable input without
attenuators Dc offset and dc reject Remote control input coupling and
offset Rugged construction
Features
- Superior tolerance to ESD
- Low dc thermal drift
- ±200 V (dc + peak ac) maximum allowable
input without attenuators
- Dc offset and dc reject
- Remote control input coupling and offset
- Rugged construction
|
| |
| |
Agilent / HP
|
1142A
|
Agilent 1142A Probe Control and Power Module
|
$599.00
|
|
|
Agilent 1142A Probe Control
and Power Module
The Agilent 1142A Probe Control and Power Module can
power and control the 1141A Differential Probe, 1144A 800 MHz Active
Probe and the 1145A 750 MHz Active Probe for SMD. If the instrument
does not have an internal 50-ohm termination, an external termination
can be used with high-impedance inputs.
Features
- Required for operation of Agilent 1141A
Differential Probe
- Independently powers the Agilent 1144A 800 MHz
Active Probe and the Agilent 1145A 750 MHz Active Probe for SMD
The 1141A/1142A probe system allows measurement of small differential
signals in the presence of much larger common-mode signals. It has the
following major feature:
¿ 200 MHz bandwidth
¿ Variable offset
¿ dc reject
¿ ac coupling
¿ Remote operating capability
The variable offset capability can be used to measure small ac signals
in the presence of much larger dc levels. Remote operation of key
features allows the use of the probe system in automatic test
situations. The probe can be used with an oscilloscope, spectrum
analyzer, or any instrument where differential probing is required and
a compatible 50 Ω input is available.
Power Requirements Voltage: 90 to 132/198 to 264 Vac, 47 to 440 Hz
Power: 25 VA maximum Weight Net: approximately 1.8 kg (4.0 lb)
|
| |
| |
Agilent / HP
|
11664A
|
Agilent 11664A Detector
|
Contact Sales
|
|
|
New Page 1
Agilent 11664A Detector
with option 001 APC-7 Connector
The 11664A Detector is designed to operate with the 8757,
8756, and 8755 Series Scalar Analyzers in ac mode only.
- Frequency Range: 10MHz to 18GHz
- Dynamic Range: +16 to -60 dBm
|
| |
| |
Agilent / HP
|
85024A
|
Agilent 85024A 3 Ghz High Frequency Probe
|
$2,000.00
|
|
|
Agilent/HP 85024A 300 kHz to 3 GHz High-Frequency Probe
Agilent/HP 85024A 300 kHz to 3 GHz High-Frequency Probe
The Agilent/HP 85024A High-Frequency Probe makes it easy to perform in-circuit
measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of
resistance permits high frequency probing without adversely loading the circuit
under test. Excellent frequency response and unity gain guarantee high accuracy
in swept measurements with this probe. High probe sensitivity and low distortion
levels allow measurements to be made while taking advantage of the full dynamic
range of RF analyzers. Spectrum Analyzers that supply probe power from the front
panel include the 8568B, 8590B, 8591A,8560A, 8561B, 8562A/B and 71100A. RF
Network Analyzers such as the 8733D, 8752C, 8751A, 3577A, and 4195A are also
directly compatible. You can use this probe with other instruments by using the
1122A Probe Power Supply (sold separately) or any dual ±15V, 130 mA supply.
Features
Specifications
(Terminated with 11880-60001 Type-N Adapter)
Specifications describe the warranted performance over the temperature range of
25° C ±5° C (except where noted). Supplemental characteristics are intended to
provide information useful in applying the instrument by giving unwarranted
performance parameters. These are denoted as
typical,
nominal,
or
approximate.
- Input capacitance (at 500 MHz) < 0.7pF (nominal)
- Input resistance 1 M ohm (nominal)
- Bandwidth 300 kHz to 3 GHz (nominal)
- Usable to 100 kHz
- Average gain 0 dB ± 1.25 dB
Average gain is defined as the average of the maximum and minimum gains over the
frequency range of 300 kHz to 1 GHz (maximum gain + minimum gain)/2.
- Frequency response (relative to Average Gain): 300 kHz to 1 GHz ±1.25 dB 1 GHz
to 3 GHz ±2.5 dB
- Average noise level < 1 mV, 10 Hz to 10 MHz
- Input voltage for <1 dB compression 0.3 V
Supplemental Characteristics
- Noise figure Below 100 MHz < 50 dB 100 MHz to 3 GHz < 25 dB
- Pulse transition time 200 psec
- Distortion (at 0.3 V) <
30 dBc
- Maximum safe input Probe alone ±1.5 V peak RF, ±50 V DC Probe with 10:1 divider
±15 V peak RF, ±200 V DC
- 10:1 divider characteristics
- Input capacitance < 0.7 pF
- Input resistance 1 M ohm
- Input voltage for 1 dB compression 3 V
- Power supplied by certain Agilent instruments or Agilent 11899A probe power
supply +15 V/130 mA,
12.6 V/45 mA
- Weight Net 0.255 kg (0.563 lb), Shipping 1.49 kg (3.3 lb) Dimensions Probe
assembly length 1245 mm (49 in)
|
| |
| |
Agilent / HP
|
1122A
|
Agilent/HP 1122A External Probe Power Supply
|
$295.00
|
|
|
New Page 1
Agilent/HP 1122A External Probe Power Supply
The HP 1122A is a regulated probe power supply
that provides all power requirements for simultaneous operation of up to four
active probes.
For use with active FET probes
-
1123A Active Probe
-
1120A Active Probe
-
85024A Active Probe
|
| |
| |
Agilent / HP
|
1131A
|
Agilent/HP 1131A 3.5 GHz InfiniiMax Probe Amplifier
|
Contact Sales
|
|
|
Agilent/HP 1131A 3.5 GHz InfiniiMax Probe Amplifier Agilent/HP 1131A 3.5 GHz InfiniiMax Probe Amplifier Rent me for $350 a month The InfiniiMax 3.5 GHz 1131A probe amplifier (in conjunction with the E2669A differential or E2668A single-ended connectivity kits), was designed to be used with the Infiniium 2.5 GHz 54853A oscilloscope. This combination provides a full system bandwidth of 2.5 GHz to the probe tip. InfiniiMax maximizes measurement performance for both hands-on (e.g., browsing) or hands-off measurements, such as solder-in, socketed or SMA connections. Features Bandwidth:Range:- Dynamic Range: +/- 2.5V
- DC Offset Range: +/- 12V
- Maximum Voltage: +/- 30V
Input Impedance:- Differential Input R: 50 kOhm
- Differential Input C: 0.27-0.34 pF
- Single Ended Input R: 25 kOhm
- Single Ended Input C: 0.44-0.67 pF
The 1131A InfiniiMax Active Probing System allows probing of differential and single-ended signals to a bandwidth of over 3.5 GHz with excellent common mode rejection. Additionally, Agilent¿s resistor-at-the-tip technology (introduced in the 115X probe family) provides high fidelity and low input loading. This system uses interchangeable probe heads to optimize the performance and usability of three connection types: hand browsing, solder-in and plug-on socket. Differential probe heads offer easy measurement of differential signals and greatly improve the measurement of single-ended signals. Single-ended probe heads offer extremely small size for probing single-ended signals in confined spaces with some reduction in performance. The probe heads provided for this system are:¿ Differential Hand-held Browser (or for probe holders) allows temporary connection to points in a system. This probe head provides the highest performance hand-held browser for measuring differential and single-ended signals while maintaining excellent usability due to the adjustable tip spacing and full z-axis compliance. ¿ Differential Solder-In Probe Head allows a soldered connection into a system for a reliable, hands-free connection. This probe head provides full bandwidth performance with the lowest input loading for probing differential and single-ended signals. At the tip it uses a miniature axial lead resistor with 8 mil diameter leads which allows connection to very small, fine pitch targets ¿ Differential Socket-Tip Probe Head provides sockets that accept 20 mil diameter pins with 100 mil spacing. The intended application for this probe head is to insert two of the supplied 20 mil diameter lead resistors into the sockets and then solder the resistors into the target system. This allows a removable, hands-free connection that provides full bandwidth with a minor increase in capacitance over the solder-in probe head for probing differential and single-ended signals. Additionally, 3.6 cm resistor tip wire accessories are provided for high fidelity lower bandwidth probing of signals with very wide spacing. It is recommended that a 25 mil diameter plated through hole on the board for mounting the lead resistors.¿ Single-ended Hand-held Browser (or for probe holders) allows temporary connection to points in a system for single-ended signals only. This browser has lower bandwidth than the differential browser, but is very small which allows probing in tight areas.
|
| |
| |
Agilent / HP
|
1145A
|
Agilent/HP 1145A 750 MHz 2 Channel Active Oscilloscope Probe
|
Contact Sales
|
|
|
Agilent/HP 1145A 750 MHz 2 Channel Active Oscilloscope Probe
Agilent/HP 1145A 750 MHz 2 Channel Active
Oscilloscope Probe
Rent me for $100 a month
The Agilent 1145A active probe for surface mount devices, provides
an easy, lightweight, reliable connection to SMDs on PC boards and
backplanes while delivering active probe performance down to the
tip. Its unique design also presents a powerful combination of
industry standard compatibility and superior reliability. The probes
basic contact is a standard 25 mil square pin socket that houses
passive circuitry. The active circuitry is contained in a plastic
pod 13 inches from the tip. This design ensures a small, lightweight
and rugged tip.
Features
- 2 channels per assembly
- dc to 750 MHz probe bandwidth
- 10X attenuation
- Powered directly by Agilent 54520, Agilent 54522, Agilent
54540, and Agilent 54542 oscilloscopes
- Use the Agilent 1142A external power supply with any other
instrument with 50-ohm inputs
Surface-mount packages on PC
boards have become the norm rather than the exception. In the future, nearly 100 percent of both sides of a
typical PC board will use SMDs. As a result, bulky probes may become useless
as package sizes get smaller and
smaller.
The 2-channel Agilent 1145A provides
easy and reliable connection to SMDs
on PC boards and backplanes, while
delivering active probe performance
down to the tip. Its unique design
also presents a powerful combination
of industry-standard compatibility
and superior reliability. The probe¿s
basic contact is a standard 25-mil
square pin socket that houses only
passive circuitry. The active circuitry
is contained in a plastic pod 13 inches
from the tip. This design ensures a
small, lightweight, and rugged tip.
The electrical performance of the
1145A is unmatched by any off-the shelf
probe designed for SMD probing.
The probe combines high bandwidth,
high input resistance, and low input capacitance. This combination
is superior to that of passive divider
probes that have higher input capacitance
because it provides minimal circuit
loading at high and low frequencies. As signal speeds increase,
passive divider probes don't deliver
the performance needed. This lower
performance can result in waveshapes
that do not represent the actual signal.
The 1145A used with an 54542A
scope, for example, introduces the
equivalent of only 1/2 of a typical
CMOS gate load (approximately 3.0 pF
per gate) to a CMOS circuit. Other
SMD probes used with comparable
scopes can introduce 1 1/2 or more gate
loads to the circuit under test.
|
| |
| |
Agilent / HP
|
1147A
|
Agilent/HP 1147A Infiniium Current Probe
|
Contact Sales
|
|
|
Agilent/HP 1147A Infiniium Current Probe
Agilent/HP 1147A
Infiniium
Current Probe
Rent me for $150 a month
The Agilent/HP 1147A is a wide bandwidth, active current probe
for 54800 Series Infiniium, DSO5000 Series and DSO/MSO6000 Series oscilloscopes.
The probe features flat bandwidth (DC to 50 MHz), low noise (<2.5 mA rms) and
low circuit insertion loss. The 1147A is ideal for capturing transient current
signals such as those found in motor controllers, in switching power supplies,
inverters and current amplifiers driving inductive loads. The 1147A is
compatible with Agilent's AutoProbe interface, which completely configures the
oscilloscope for the probe. Probe power is provided by the scope, so there is no
need for an external amplifier or power supply. A snap-on BNC connector
simplifies connecting the probe to the scope.
Features
- Wide bandwidth: DC to 50 MHz
- High S/N ratio, low current measurement capability
- 15 A continuous, 50 A peak dc + ac pulse current
- Easy protect function at excessive input
- Demagnetizing switch to remove any residual
magnetism that builds up in the magnetic core
- AutoProbe interface compatible
A Degauss function allows the removal of any
residual magnetism that has built up in the magnetic core due to power on/off
switching or excessive input. In addition, voltage offset or temperature drift
on the 1147A probe can be easily corrected by using the zero adjustment dial.
|
| |
| |
Agilent / HP
|
1154A
|
Agilent/HP 1154A 500 MHz Differential Probe
|
Contact Sales
|
|
|
Agilent/HP 1154A 500 MHz Differential Probe
Agilent/HP 1154A 500 MHz Differential Probe
Rent me for $200 a month
For the Infiniium Series
Oscilloscopes
The 1154A is a wide-band differential active probe. The probe
features low noise, low input capacitance, high common mode rejection, and Field
Effect Transistor (FET) buffered inputs in the probe head. User-selectable
offset gives the probe flexibility to measure a large range of signal types.
Plug-on attenuators and AC coupling accessories further extend the application
range. Included interconnect accessories allow connection to surface mount and
through-hole components with minimal signal degradation. The input receptacles
in the probe head are compatible with standard 0.025" (0.635 mm) square pins,
which provide a convenient low-cost method of creating device characterization
test fixtures. The 1154A is ideal for acquiring high speed differential signals
such as those found in disk drive read channels, differential LAN, video, etc.
The high impedance characteristics of both inputs allow the probe to be used as
a FET probe to make single-ended measurements in digital systems without
introducing a ground loop as a conventional FET probe would.
The 1154A Differential Probe is a high input impedance
amplifier. A characteristic of differential amplifiers is the ability to reject
signals that are common to the two inputs. The common mode rejection ratio (CMRR)
is the measurement of this ability. It is expressed as the ratio between the
amplitudes of the common mode and differential signals that produce equal
outputs. These measurements can be referred to the probe input, if the
differential gain is known. The CMRR is usually expressed in dB: The CMRR is
only specified for unity Gain. The ability to reject common mode signals depends
on the balance designed into the probe amplifier. As the frequency of the common
mode signal increases, it becomes harder to balance the amplifier parasitic
parameters. This leads to degradation of the CMRR.
The CMRR of the 1154A Differential probe is specified from the
probe tip. This method of specifying the probe CMMR eliminates the effects of
source impedance, provided the connections from the probe tip to the signal
source are symmetrical.
|
| |
| |
Agilent / HP
|
1159A
|
Agilent/HP 1159A 1 GHz Differential Probe
|
Contact Sales
|
|
|
Agilent/HP 1159A 1 GHz Differential Probe
Agilent/HP 1159A 1 GHz Differential Probe
Rent me for $250 a month
for the Infiniium Series
Oscilloscopes
The Agilent/HP 1159A is a wide-band differential
active probe. The probe features low noise, low input capacitance, high common
mode rejection, and Field Effect Transistor (FET) buffered inputs in the probe
head. User-selectable offset gives the probe flexibility to measure a large
range of signal types. Plug-on attenuators and AC coupling accessories further
extend the application range. Included interconnect accessories allow
connection to surface mount and through-hole components with minimal signal
degradation. The input receptacles in the probe head are compatible with
standard 0.025" (0.635 mm) square pins, which provide a convenient low-cost
method of creating device characterization test fixtures. The 1159A is ideal for
acquiring high speed differential signals such as those found in disk drive read
channels, differential LAN, video, and so on. The high impedance characteristics
of both inputs allow you to use the probe as a FET probe to make single-ended
measurements in digital systems without introducing a ground loop as a
conventional FET probe would.
Features
- AutoProbe interface compatible
- Low noise and low input capatitance
- External attenuators and ac coupler
- Superior tolerance to ESD
- Small size and rugged attenuation
|
| |
| |
Agilent / HP
|
1160A
|
Agilent/HP 1160A 500 MHz Passive Oscilloscope Probe
|
Contact Sales
|
|
|
Agilent/HP 1160A 500 MHz Passive Oscilloscope Probe
Agilent/HP 1160A 500 MHz Passive Oscilloscope
Probe
The Agilent/HP 1160A Miniature Passive probe is a small, rugged,
general purpose probe for
use with the 54810A, 54815A,
54820A and 54825A Infiniium
Oscilloscopes. It is fully
compatible with the Agilent
AutoProbe interface which
completely configures the
Agilent Infiniium
Oscilloscope for the probe.
The probe is built and
tested for high reliability.
The cable has a Kevlar
strengthener for added pull
strength. The general
purpose retractable hook tip
is made from a durable music
wire and probe tips are
replaceable. The handle of
the probe can be removed,
leaving a miniature probe
body with a narrow and sharp
tip ideal for probing dense
circuit boards.
Features
- Kevlar-reinforced cable and durable probe hook
- Compatible with Infiniium scope AutoProbe interface
- System bandwidth (scope + probe): 500 MHz
- 10/1 Probe
The 1160A family probes are compatible with the
AutoProbe interface, which completely configures the Infiniium oscilloscope for
the probe. A snap-on BNC connector simplifies attaching the probe to the scope.
Leads are available for connecting to a wide variety of test points.
|
| |
| |
Agilent / HP
|
1161A
|
Agilent/HP 1161A 500 MHz Passive Oscilloscope Probe
|
Contact Sales
|
|
|
Agilent/HP 1161A 500 MHz Passive Oscilloscope Probe
Agilent/HP 1161A 500 MHz Passive Oscilloscope
Probe
The Agilent 1161A miniature passive probe is a small, rugged, general purpose probe for use with the Agilent 54835A, 54845A/B, and 54846A/B Infiniium oscilloscopes. It is fully compatible with the Agilent AutoProbe interface which completely configures the Agilent Infiniium oscilloscope for the probe.
It is fully
compatible with the Agilent AutoProbe interface which
completely configures the
Agilent Infiniium
Oscilloscope for the probe.
The probe is built and
tested for high reliability.
The cable has a Kevlar
strengthener for added pull
strength. The general
purpose retractable hook tip
is made from a durable music
wire and probe tips are
replaceable. The handle of
the probe can be removed,
leaving a miniature probe
body with a narrow and sharp
tip ideal for probing dense
circuit boards.
Features
- Kevlar-reinforced cable and durable probe hook
- Compatible with Infiniium scope AutoProbe interface
- System bandwidth (scope + probe): 500 MHz
- 10/1 Probe
The 1161A family probes are compatible with the AutoProbe interface, which completely configures the Infiniium oscilloscope for
the probe. A snap-on BNC connector simplifies attaching the probe to the scope.
Leads are available for connecting to a wide variety of test points.
|
| |
| |
Agilent / HP
|
1165A
|
Agilent/HP 1165A 500 MHz Passive Oscilloscope Probe
|
Contact Sales
|
|
|
Agilent/HP 1165A 500 MHz Passive Oscilloscope Probe
Agilent/HP 1165A 500 MHz Passive Oscilloscope
Probe
The Agilent/HP 1165A
miniature passive probe is a
small, rugged, general
purpose probe for use with
the InfiniiVision 7000,
Infiniium 8000 Series and
54830 Series oscilloscopes.
It is fully compatible with
the Agilent Auto Probe
interface which completely
configures the Infiniium
oscilloscope for the probe. The probe is built and tested for high reliability. The cable has a
Kevlar strengthener for added pull strength. The general purpose retractable
hook tip is made from a durable music wire and probe tips are replaceable. The
handle of the probe can be removed, leaving a miniature probe body with a narrow
and sharp tip ideal for probing dense circuit boards.
Features
- Kevlar-reinforced cable and durable probe hook
- Compatible with Infiniium scope AutoProbe
interface
- System bandwidth (scope + probe): 500 MHz
- 10/1 Probe
- 10 Mohm input resistance
- Oscilloscope compensation range: 12-14 pF
- Max input voltage: 300V (dc + peak ac) CAT II
The 1165A family probes are compatible with the AutoProbe interface, which
completely configures the Infiniium oscilloscope for the probe. A snap-on BNC
connector simplifies attaching the probe to the scope. Leads are available for
connecting to a wide variety of test points.
|
| |
| |
Agilent / HP
|
11945A
|
Agilent/HP 11945A EMI Close Field Probe Set
|
Contact Sales
|
|
|
Agilent/HP 11945A EMI Close Field Probe Set Agilent/HP 11945A EMI Close Field Probe Set Rent me for $400 a month The Agilent/HP 11945A close-field probe set includes both the 11940A and 11941A probes to provide full coverage from 9 kHz to 1 GHz. This set provides a powerful measurement tool for electrical and mechanical designers who want to search for and eliminate sources of interference from their products early in the design process. Option E51 adds the Agilent/HP 11909A preamplifier, a 36 inch (914 mm) Type-N cable and a carrying bag to store and protect the entire set of probes, preamplifier, and cables. - Measurement tool for electrical and mechanical designers
- Searches for sources of interference from their products early in the design processDesigned to measure magnetic-field radiation from surface currents, slots, cables, and ICs for EMC diagnostic and troubleshooting measurements.
- Operates from 9 kHz to 1 GHz
- Five antenna factors with each probe for calculating absolute magnetic-field strength (dBµA/m) from dBµV reading of a spectrum analyzer.
- Comes with a 2-meter RG-223 coaxial cable and SMA (f)-to -type-N (m) adapter, and an SMA (f)-to-BNC (m) adapter for each probe.
- The close field probe set includes both the Agilent/HP 11940A and 11941A probes for full coverage from 9 kHz to 1 GHz.
- Option E51 adds the HP / Agilent/HP 8447F Option H64 dual preamplifier ( or HP / Agilent/HP 11909A preamplifier ), a 36-inch (914-mm) type-N cable, and a carrying bag for storage and protection of the entire set.
Agilent/HP 11940A Probe Specifications30 MHz to 1 GHz Maximum Input Power: 0.5 watts Temperature Range: Variation over 0 °C to +40 °C Dielectric Breakdown: ±1 kV, typical Connector Type: SMA, replaceable barrel VSWR: <3:1, typical Antenna Factor Accuracy: Individually calibrated to within ±2 dB in a 377 ohm field impedanceAgilent/HP 11941A Probe Specifications9 kHz to 30 MHz Maximum Input Power: 0.5 watts Temperature Range: Variation over 0 °C to ±40 °C Dielectric Breakdown: ±1 kV, typical Connector Type: SMA, replaceable barrel VSWR: <3:1 Antenna Factor Accuracy: Individually calibrated to within ±2 dB in a 377 ohm field impedanceAgilent/HP 8447F Specifications - Frequency Range:
9 kHz to 50 MHz 100 kHz to 1.3 GHz - Noise Figure:
<7.0 dB 8.5 dB - Gain:
28 dB 26 dB - Gain Flatness:
±2.0 dB ±1.5 dB - Connector:
Type-N (f) Type-N (f)
|
| |
| |
Agilent / HP
|
16089D
|
Agilent/HP 16089D Alligator Clip Lead
|
Contact Sales
|
|
|
Agilent/HP 16089D Alligator Clip Lead
Agilent/HP 16089D Alligator Clip Lead
Rent me for $200 a month
The Agilent 16089D makes it possible to measure odd-shaped
components that cannot be measured with conventional fixtures. It is equipped
with four alligator clips.
Features
- Measurement Instruments: Agilent 4192A, Agilent 4194A
(Impedance Mode), Agilent 4263B, Agilent 4278A, Agilent 4284A, Agilent 4285A
and Agilent E4980A
- Frequency: 5Hz to 100kHz
- DC Bias: -35V to +35V
- Operating Temperature: 0 to 55degC
- Terminal Diameter: 5mm or less
- Clip: Four terminal (Agilentot,Hcur,Lpot, and Lcur)
- Cable Length: Approx. 0.94m (from connector to clip tip)
- Terminal Connection: BNC, 4 terminal-pair
|
| |
| |
Agilent / HP
|
34134A
|
Agilent/HP 34134A 50 Amp AC/DC Current Probe
|
Contact Sales
|
|
|
Agilent/HP 34134A 50 Amp AC/DC Current Probe
Agilent/HP 34134A 50 Amp AC/DC Current Probe
Rent me for $100 a month
The Agilent/HP Technologies 34134A current probe
measures low DC or AC from 10 mA to 50 Amps DC and up to 40 Amps AC. This
battery-powered clamp-on probe can be used with digital multimeters, voltmeters,
or other voltage-measuring instruments. The probe jaws clamp around the
conductor under test, allowing current measurements without breaking the
circuit. Hall sensor technology senses the magnetic field produced by the
current measured and generates a millivolt DC or AC output signal. The narrow
jaw is designed for optimum use in crowded wiring in industrial and automotive
environments.
The 34134A current probe is compatible with any DMM, or other
voltage measuring instrument which has the following features:
- Range and resolution capable of displaying 1 mV of input.
- Voltmeter accuracy (uncertainty) of 0.75% or better to take full
advantage of the accuracy of the probe.
- Minimum input impedance of 100 kΩ (1 V/A range) or 10 kΩ (10
mV/A range).
- Input jacks that accept 4mm shrouded banana plugs.
Electrical Specifications
-
Current Range DC: 10 mA to 2 A DC: 100 mA to 80 A
-
AC: 10 mA to 1.5 A AC: 100 mA to 60 A
-
Output Signal (AC/DC) 1 mV/mA (2 V @ 2 A) 10 mV/A
-
Accuracy* ±2% reading ±5mA 500 mA to 50 A DC/40 A
AC: ±4% reading ±20 mA
-
50 to 80A DC: ±12% reading
-
0 to 60A AC: ±12% reading
-
Frequency Range DC to 8 kHz @ ¿3 dB DC to 8 kHz
-
Phase Shift DC to 65 Hz: 1° DC to 65 Hz: 1°
-
Minimum Input Resistance 100 kΩ 100 kΩ of Instrument
-
Noise DC to 1 Hz: 1.5 mV DC to 1 Hz: 15μV, 1 Hz to
10 kHz: 14 mV 1 Hz to 10 kHz: 140μV, 0 kHz to 100 kHz: 18 mV 0 kHz
to 100 kHz: 180μV
-
Slew Rate @ 5 A 120 mV/ μs 5.5 mV/ μs
* Accuracies are given for an ambient temperature of 23 °C ±3
°C, relative humidity of 20 to 75%, conductor centered in jaw window, probe
zeroed, no hysteresis in DC, DC to 40 to 100Hz sine wave (1mV/mA range) or DC
and 40 to 1 kHz sine wave (10mV/A range), 1 minute warm-up, battery at 9V,
appropriate load impedance, magnetic field <40A/m and no common mode.
|
| |
| |
Agilent / HP
|
41800A
|
Agilent/HP 41800A Active Probe
|
$1,495.00
|
|
|
Agilent/HP 41800A 5 Hz to 500 MHz Active Probe
Agilent/HP 41800A 5 Hz to 500 MHz Active
Probe
Rent me for $200 a month
The Agilent/HP 41800A Active Probe provides high input impedance
from 5 Hz to 500 MHz. The Agilent/HP 41800A is a valuable tool when used with a
network and spectrum analyzer for circuit signal analysis. Output is 50 ohm
impedance and the unit requires a probe power source. This is standard on many
Agilent Products.
The
Agilent/HP 41800A active probe provides high input impedance from 5 Hz to 500
MHz. The 41800A is a valuable tool when used with a network and spectrum
analyzer for circuit signal analysis. The 41800A improves your circuit design
and evaluation for audio, video, HF, and VHF bands. The low input capacitance
offers probing with negligible circuit loading, making it effective for precise
in-circuit measurements.
For Both Spectrum and Network Analysis
The 41800A can be used with a spectrum analyzer to
evaluate the quality of circuits by measuring spurious level, harmonics, and
noise. The active probe can also be used with a network analyzer to perform
gain, phase, and group-delay measurements at the circuit-level.
Retractable Metal Sleeve for Protection
In addition to excellent performance, the 41800A
also has a design to protect the probe tip. The probe has a retractable metal
sleeve which protects the probe tip from a physical damage when not used and
also from electro-static discharge (ESD) damage.
Product Specifications
Specification (Terminated with Agilent 11880A Type N Adapter) · Bandwidth: 5 Hz to 500 MHz · Probe Gain: 0 dB · Input
R,C(typical) :100 kilo ohm,3 pF(probe alone) 1 megaohm,1 pF(with
10:1,100:1 divider) · Frequency Response Relative to 50 MHz:
+/-2 dB @<50 Hz +/-1 dB @50 Hz to 200 MHz +1.5/-2 dB @>200 MHz · Average Noise Level(typical): 10 nV/ Hz ^-0.5 · 2nd
Harmonic Distortion(typical) :<-50dBc@-20dBm(250 MHz) input ·
3rd Order Intermodulation Distortion(typical) :<-70dBc@-26dBm
two signal input(400 MHz,400.5 MHz) · 1 dB Gain Compression :
>+3dBm input @500MHz · Maximum Allowable Input: AC+DC:+/-40
V(probe alone)
AC: 0.5Vrms(probe alone) AC: 0.5Vrms (with 1:1
divider) AC: 5Vrms (with 10:1 divider) AC: 30Vrms
(with 100:1 divider)
· Output Connector: 50 ohm type N male · Power:
+15V/85mA,-12.6V/65mA · Weight: 0.3 kg(probe alone) 2
kg(include accessories) · Length: approximately 1.2m ·
Operating Temperature Humidity: O to 55 degC, RH <= 95%(40
degrees Celsius)
|
| |
| |
Agilent / HP
|
85025D
|
Agilent/HP 85025D 10 MHz to 50 GHz Detector
|
Contact Sales
|
|
|
Agilent/HP 85025D 10 MHz to 50 GHz Detector
Agilent/HP 85025D 10 MHz to 50 GHz Detector
Rent me for $150 a month
The Agilent/HP 85025D detector is designed specifically for
operation with the 8757D scalar network analyzer and is not compatible with the
8756 or the 8755. The Agilent 85025D detects either a modulated (ac) or an
unmodulated (dc) microwave signal. The D in the part number indicates a 2.4 mm
male connector. Features a 5 pin DIN style connector.
|
| |
| |
Agilent / HP
|
E2668A
|
Agilent/HP E2668A InfiniiMax connectivity kit for single-ended measurements
|
$795.00
|
|
|
Agilent/HP E2668A InfiniiMax connectivity kit for single-ended measurements
Agilent/HP E2668A InfiniiMax connectivity kit
for single-ended measurements
The Agilent/HP E2668A connectivity kit is designed to be used with
the InfiniiMax 1130 Series probe
amplifiers for single-ended
measurements. Includes one
single-ended browser, one
solder-in probe head and one
socketed probe head. Includes
all necessary accessories.
Features
-
Single-ended
browser
probe
head and
ergonomic
handle
-
Single-ended
socketed
probe
heads
-
Single-ended
solder-in
probe
heads
|
| |
| |
Agilent / HP
|
N2772A
|
Agilent/HP N2772A 20 MHz Differential Probe
|
Contact Sales
|
|
|
Agilent/HP N2772A 20 MHz Differential Probe
Agilent/HP N2772A 20 MHz Differential Probe
Rent me for $100 a month
Use the Agilent N2772A Differential Probe with any Agilent
oscilloscope to safely measure floating circuits with the oscilloscope grounded.
With 20 MHz bandwidth and switchable attenuation of 20:1 and 200:1, it provides
the versatility for a broad range of applications including high-voltage
circuits, motor speed controls, power supply design, and electronic high-power
converters.
This probe requires a 9 V battery or Agilent N2773A power
supply.
Features
- Measure up to 600 V CAT III
- 20:1 and 200:1 switchable attenuation
- Supplied with a retractable hook, sharp probe tips and
alligator clips
- Bandwidth: 20 MHz
- Risetime: 17.5 ns
- Attenuation ratios: 20:1 and 200:1, selectable via switch
on probe
- High CMRR, 80 dB at 60 Hz, 50 dB at 1 MHz
- Input impedance between inputs: 10 M ohm, 5 pF
The N2772A differential probe allows you to safely
measure floating circuits, as high as 600V dc peak to ground, with the
oscilloscope grounded. It is ideal for many applications such as motor speed
controls, power supply designs and electronic high-power converters.
With 20 MHz bandwidth, switchable attenuation of
20:1 and 200:1, and a maximum voltage input of 600V, it provides the versatility
for a broad range of applications including high-voltage circuits. Each probe
comes with sharp probe tips for use on small components and in tight places and
alligator clips for connecting to larger cables. The probe is powered by a 9V
battery or by using a separate power supply.
Compatibility
The N2772A differential probe is compatible with any
oscilloscope that has the following features:
|
| |
| |
Electro-metrics
|
EHFP-30, EM-6992, 119-4146-00
|
Electro-metrics EHFP-30 Hand Held RF Probe Set
|
Contact Sales
|
|
|
Electro-metrics EHFP-30 Hand Held RF Probe Set
Electro-metrics EHFP-30 Hand Held RF Probe Set
Rent me for $100 a month
Also known as the Tektronix 119-4146-00 and
Electro-metrics EM-6992
The Electro-Metrics EM-6992 Hand Held Probe Set is
designed to assist in pinpointing the specific source of emissions during the
diagnostic testing phase of an EMI compliance investigation. A selection of
probes of varying sensitivities is provided for both E-field and H-field
analysis up to 1000 MHz.
Applications
When used with an EMI or Spectrum Analyzer, the
EM-6992 set allows easy identification of emission sources.
Configuration
The probe set contains all of the units shown below
and a custom carrying case, which has space for all probes in the set. Nominal
working impedance is 50 ohms for all probes
Model #
Description Response (Field)
EM-6993 6 cm Loop
H Field
EM-6994 3 cm Loop
H Field
EM-6995 1 cm Loop
H Field
EM-6996 3.2 cm
Ball
E Field
EM-6997 Stub
E Field
|
| |
| |
Fluke
|
80I-1010
|
Fluke 80I-1010 Current Probe
|
Contact Sales
|
|
|
Fluke 80I-1010 Current Probe
Fluke 80I-1010 Current Probe
The 80I-1010s AC/DC Current Clamp is compatible with any Fluke
ScopeMeter Test Tool, Power Harmonics Analyzer, Oscilloscope, Multimeter, or
other voltage measurement device that has the following features: BNC input
connectors or if using a meter convert the banana plugs to a BNC connector using
the adapter PM9081/001.
Features
- Current Range: 0.1 to 1000A DC or 0.1 to 700A AC
- Basic Accuracy (DC to 1kHz): 100mV/A setting= 50mA to 10A +/- 3% of
reading + 50mA ; 10mV/A setting= 50mA to 40A +/- 4% of reading + 50mA , 40A
to 80A +/- 12% of reading + 50mA, 80 to 100A +/- 15% of reading.
- Output Signal: 10A range: 100mV/A | 100A range: 10mV/A
- Bandwidth: 1Hz to 20kHz
- Working Voltage: 600V AC rms
- Maximum Conductor Size: 11.8 mm (.46 inch) diameter
- Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category
II, Working Voltage 600V
The Fluke 80I-1010 is a battery-powered Hall-effect clamp-on probe measures
AC current to 700A, DC current to 1000A. Thumbwheel ZERO control compensates for
residual core magnetism, improving the accuracy of DC measurements down to 1A.
Output is 1 mV per Amp DC or AC. Maximum conductor size: one 1.18" (30 mm) or
two 0.98" (25 mm). Accuracy: +/- (2%+1A), 1A to 100A, DC to 62 Hz. Useable to
440 Hz
|
| |
| |
Fluke
|
I2000flex
|
Fluke i2000 2000 Amp flex AC Current Clamp
|
Contact Sales
|
|
|
Fluke i2000 2000 Amp flex AC Current Clamp
Fluke i2000 2000 Amp flex AC Current Clamp
Rent
me for $50 a month
The i2000 is an AC current probe utilizing the
Rogowski principle. It can be used to measure currents up to 2000A when used in
conjunction with multimeters, recorders or data loggers. The flexible and
lightweight measuring head allows quick and easy installation in hard to reach
areas.
Features
- Three ranges: 20A, 200 A & 2000 A, 1 mV, 10 mV & 100
mV/A output
- Ideal for current measurement on thick and hard to
reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm
- CAT III 600V safety rating
|
Electrical specifications |
| Current
ranges |
|
| Load
impedance |
|
| Accuracy |
| at +25 °C |
± 1 % of range
(45 Hz to 65 Hz) |
|
| Linearity |
| 10 % to 100 %
of range |
± 0.2 % of
reading |
|
| Frequency
range |
|
|
| |
| |
Agilent / HP
|
1143A
|
HP 1143A Probe Power Module
|
$799.00
|
|
|
Agilent
1143A Probe Offset Control and Power Module
The Agilent 1143A provides power and independent offset
control for two Agilent 54700-series probes. The probe's offset can be
controlled via a 9-pin, D-subminiature connector on the rear panel of
the Agilent 1143A. Additionally, the ±50 V offset capability
extends the dynamic range of the probe measurement system beyond that
of many test and measurement instruments.
The Agilent 54701A, with the Agilent 1143A Probe Offset
Control and Power Module, is versatile enough to be used with any test
and measurement equipment with a 50 ohm input.
Features
- Agilent 1143A independently powers the Agilent
54701A
- Programmable offset
- ±50 V offset
- Number of independently operated probes: 2
- Positive power output: +17.3 V ±150 mV
- Negative power output: -17.3 V ±150 mV
- Maximum current capability (both +17.3 V and
-17.3 V supply): 300 mA
- Offset current: Variable from zero to ±5
mA
- Operating temperature: 0 to 55°C
- Operating humitity: 95% relative humidity at
40°C
- Net Weight: 1.5 kg (3.4 lbs.)
- Shipping Weight: 2.4 kg (5.4 lbs)
- Power Requirements: 90 to 132/198 to 264 Vac, 47
to 440 Hz, 40 VA max
- Dimensions: 211 mm (W) x 173 mm (D) x 78 mm (H)
(8.3 x 6.8 x 3.1 inches)
|
| |
| |
Agilent / HP
|
1152A
|
HP 1152A 2.5 GHz Active Probe
|
$1,250.00
|
|
|
Agilent 1152A 2.5 Ghz Active Probe
Rent me for $200 a month
The Agilent
1152A active probe's bandwidth, superior accuracy, and reliability make it an
ideal companion for the Agilent 54845A 1.5 GHz bandwidth oscilloscope. The low
input capacitance of the active probe eliminates distortion caused by excessive
loading. As frequency increases, probe tip capacitance decreases the impedance
of the probe by Xc=1/(2pi*fC), resulting in measurement error, depending on the
source impedance of the output device. The Agilent 1152A's low tip capacitance
becomes a distinct advantage as frequency increases. Nonintrusive, reliable
probing provides faithful reproduction of signals.
Features
- 2.5 -GHz bandwidth
-
140 ps rise time
- 1% long-term flatness
- ±0.5% dc gain accuracy
- 200 Vac max input
tolerance
- ±12 kV ESD tolerance
- Pliable, replaceable probe tips
- Input Voltage ±5 V dc + peak
ac
- AutoProbe interface compatible
- Bandwidth (-3 dB): >2.5 GHz
- Risetime (10%
to 901%): <140 ps (calculated from tr=0.35/bandwidth)
- Attenuation factor:
10:1
- dc Input resistance: 100 kÙ ±1%
- Input capacitance: 0.6 pF (typical)
-
Maximum input voltage: ±40 V (dc + peak ac(<20 MHz))
|
| |
| |
Agilent / HP
|
54003A
|
HP 54003A Pod & 10435A Probe w/Manuals
|
Contact Sales
|
|
|
10435A, 10:1 MINI PROBE 1 METER 1 MEGOHM INPUT 54003A 1 MEGAOHM, 10:1 PROBE POD FOR USE WITH HP 54100D |
| |
| |
Agilent / HP
|
E3452A
|
HP E3452A Emulation Probe for 16505A
|
Contact Sales
|
|
|
for use with the PowerPC 400 and 600, with 16505A software Ver A.01.23 AC adapter, cables, manual and adapters |
| |
| |
Kaltman Creations LLC
|
Hyperlog 30100
|
Kaltman Creations Hyperlog 30100 380 MHz-10 GHz EMC Antennas
|
$2,800.00
|
|
|
Kaltman Creations Hyperlog 30100 380 MHz-10 GHz EMC Antennas Kaltman Creations
Hyperlog 30100 380 MHz-10 GHz EMC Antennas Rental and lease options are available please call Look at the Price!
One of the main advantages of the these antennas is that they
are not "naked" (directly exposed to the atmospheric elements). The antenna
houses their gold plated, Teflon elements in a specially constructed, high
technology Radom housing. This Radom housing was designed in such a way that its
shape, material and special coating have virtually no influence on measurements;
not even in the case of dew or humidity collection on the surface. And of course
the Radom housing helps to prevent oxidation, fissures, and general physical
damage.
Professional broadband measurement antennas have one distinct
disadvantage, they are extremely expensive. The HyperLOG® series of antennas
offers a cost-effective alternative while maintaining above industry
specifications and standards. Whatever your antenna needs - point to point
communication, fixed receiving, voice, data, machine control, or for use with
Spectran RF Spectrum Analyzers - the HyperLOG antennas represents a true cost
effective alternative!
Features
- Only one single broadband antenna is
required for the 380MHz to 18GHz frequency range (various other model
ranges available)
-
Complete ISO calibration certificate
(optional)
-
Top-quality, high-tech TEFLON coated Gold
elements
-
High-tech Radom with a modern, aesthetic
design
-
Freely align able polarization
-
Calibration data can be saved and read-back
from an IC
within the antenna
-
Excellent forward / backward ratio
-
Excellent symmetry of radiation patterns
-
Integrated 5/8" tripod socket
-
Suitable for mobile use
-
Suitable for outdoor installation
-
Robust, splash proof design
-
Small, lightweight design
- Well suited for EMC measurements with spectrum analyzers
Antenna package includes:
- HyperLOG
antenna
- Standard
calibration data (model specific, in
10MHz steps)
- Aluminum
carrying case with custom padding
- Detachable
pistol-grip handle which converts into a
mini-tripod stand
- Sturdy,
multi-purpose aluminum tripod with
spirit-level
- Special SMA tool with over-torque
protection
|
| |
| |
Kaltman Creations LLC
|
Hyperlog 30180
|
Kaltman Creations Hyperlog 30180 380 MHz-18 GHz EMC Antennas
|
$5,594.00
|
|
|
Kaltman Creations Hyperlog 30180 380 MHz-18 GHz EMC Antennas Kaltman Creations
Hyperlog 30180 380 MHz-18 GHz EMC Antennas Rental and lease options are available please call Look at the Price!
One of the main advantages of the these antennas is that they
are not "naked" (directly exposed to the atmospheric elements). The antenna
houses their gold plated, Teflon elements in a specially constructed, high
technology Radom housing. This Radom housing was designed in such a way that its
shape, material and special coating have virtually no influence on measurements;
not even in the case of dew or humidity collection on the surface. And of course
the Radom housing helps to prevent oxidation, fissures, and general physical
damage.
Professional broadband measurement antennas have one distinct
disadvantage, they are extremely expensive. The HyperLOG® series of antennas
offers a cost-effective alternative while maintaining above industry
specifications and standards. Whatever your antenna needs - point to point
communication, fixed receiving, voice, data, machine control, or for use with
Spectran RF Spectrum Analyzers - the HyperLOG antennas represents a true cost
effective alternative!
Features
- Only one single broadband antenna is
required for the 380MHz to 18GHz frequency range (various other model
ranges available)
-
Complete ISO calibration certificate
(optional)
-
Top-quality, high-tech TEFLON coated Gold
elements
-
High-tech Radom with a modern, aesthetic
design
-
Freely align able polarization
-
Calibration data can be saved and read-back
from an IC
within the antenna
-
Excellent forward / backward ratio
-
Excellent symmetry of radiation patterns
-
Integrated 5/8" tripod socket
-
Suitable for mobile use
-
Suitable for outdoor installation
-
Robust, splash proof design
-
Small, lightweight design
- Well suited for EMC measurements with spectrum analyzers
Antenna package includes:
- HyperLOG
antenna
- Standard
calibration data (model specific, in
10MHz steps)
- Aluminum
carrying case with custom padding
- Detachable
pistol-grip handle which converts into a
mini-tripod stand
- Sturdy,
multi-purpose aluminum tripod with
spirit-level
- Special SMA tool with over-torque
protection
|
| |
| |
Kaltman Creations LLC
|
Hyperlog 4040
|
Kaltman Creations Hyperlog 4040 400MHz-4GHz EMC Antennas
|
$980.00
|
|
|
Kaltman Creations Hyperlog 4040 400MHz-4GHz EMC Antennas Kaltman Creations
Hyperlog 4040 400 MHz-4 GHz EMC Antennas Rental and lease options are available please call Look at the Price!
One of the main advantages of the these antennas is that they
are not "naked" (directly exposed to the atmospheric elements). The antenna
houses their gold plated, Teflon elements in a specially constructed, high
technology Radom housing. This Radom housing was designed in such a way that its
shape, material and special coating have virtually no influence on measurements;
not even in the case of dew or humidity collection on the surface. And of course
the Radom housing helps to prevent oxidation, fissures, and general physical
damage.
Professional broadband measurement antennas have one distinct
disadvantage, they are extremely expensive. The HyperLOG® series of antennas
offers a cost-effective alternative while maintaining above industry
specifications and standards. Whatever your antenna needs - point to point
communication, fixed receiving, voice, data, machine control, or for use with
Spectran RF Spectrum Analyzers - the HyperLOG antennas represents a true cost
effective alternative!
Features
- Only one single broadband antenna is
required for the 380MHz to 18GHz frequency range (various other model
ranges available)
-
Complete ISO calibration certificate
(optional)
-
Top-quality, high-tech TEFLON coated Gold
elements
-
High-tech Radom with a modern, aesthetic
design
-
Freely align able polarization
-
Calibration data can be saved and read-back
from an IC
within the antenna
-
Excellent forward / backward ratio
-
Excellent symmetry of radiation patterns
-
Integrated 5/8" tripod socket
-
Suitable for mobile use
-
Suitable for outdoor installation
-
Robust, splash proof design
-
Small, lightweight design
- Well suited for EMC measurements with spectrum analyzers
Antenna package includes:
- HyperLOG
antenna
- Standard
calibration data (model specific, in
10MHz steps)
- Aluminum
carrying case with custom padding
- Detachable
pistol-grip handle which converts into a
mini-tripod stand
- Sturdy,
multi-purpose aluminum tripod with
spirit-level
- Special SMA tool with over-torque
protection
|
| |
| |
Kaltman Creations LLC
|
Hyprtlog 4060
|
Kaltman Creations Hyperlog 4060 400 MHz-6 GHz EMC Antennas
|
$1,400.00
|
|
|
Kaltman Creations Hyperlog 4060 400 MHz-6 GHz EMC Antennas Kaltman Creations
Hyperlog 4060 400 MHz-6 GHz EMC Antennas Rental and lease options are available please call Look at the Price!
One of the main advantages of the these antennas is that they
are not "naked" (directly exposed to the atmospheric elements). The antenna
houses their gold plated, Teflon elements in a specially constructed, high
technology Radom housing. This Radom housing was designed in such a way that its
shape, material and special coating have virtually no influence on measurements;
not even in the case of dew or humidity collection on the surface. And of course
the Radom housing helps to prevent oxidation, fissures, and general physical
damage.
Professional broadband measurement antennas have one distinct
disadvantage, they are extremely expensive. The HyperLOG® series of antennas
offers a cost-effective alternative while maintaining above industry
specifications and standards. Whatever your antenna needs - point to point
communication, fixed receiving, voice, data, machine control, or for use with
Spectran RF Spectrum Analyzers - the HyperLOG antennas represents a true cost
effective alternative!
Features
- Only one single broadband antenna is
required for the 380MHz to 18GHz frequency range (various other model
ranges available)
-
Complete ISO calibration certificate
(optional)
-
Top-quality, high-tech TEFLON coated Gold
elements
-
High-tech Radom with a modern, aesthetic
design
-
Freely align able polarization
-
Calibration data can be saved and read-back
from an IC
within the antenna
-
Excellent forward / backward ratio
-
Excellent symmetry of radiation patterns
-
Integrated 5/8" tripod socket
-
Suitable for mobile use
-
Suitable for outdoor installation
-
Robust, splash proof design
-
Small, lightweight design
- Well suited for EMC measurements with spectrum analyzers
Antenna package includes:
- HyperLOG
antenna
- Standard
calibration data (model specific, in
10MHz steps)
- Aluminum
carrying case with custom padding
- Detachable
pistol-grip handle which converts into a
mini-tripod stand
- Sturdy,
multi-purpose aluminum tripod with
spirit-level
- Special SMA tool with over-torque
protection
|
| |
| |
Kaltman Creations LLC
|
Hyperlog 60100
|
Kaltman Creations Hyperlog 60100 680 MHz-10 GHz EMC Antennas
|
$2,240.00
|
|
|
Kaltman Creations Hyperlog 60100 680 MHz-10 GHz EMC Antennas Kaltman Creations
Hyperlog 60100 680 MHz-10 GHz EMC Antennas Rental and lease options are available please call Look at the Price!
One of the main advantages of the these antennas is that they
are not "naked" (directly exposed to the atmospheric elements). The antenna
houses their gold plated, Teflon elements in a specially constructed, high
technology Radom housing. This Radom housing was designed in such a way that its
shape, material and special coating have virtually no influence on measurements;
not even in the case of dew or humidity collection on the surface. And of course
the Radom housing helps to prevent oxidation, fissures, and general physical
damage.
Professional broadband measurement antennas have one distinct
disadvantage, they are extremely expensive. The HyperLOG® series of antennas
offers a cost-effective alternative while maintaining above industry
specifications and standards. Whatever your antenna needs - point to point
communication, fixed receiving, voice, data, machine control, or for use with
Spectran RF Spectrum Analyzers - the HyperLOG antennas represents a true cost
effective alternative!
Features
- Only one single broadband antenna is
required for the 380MHz to 18GHz frequency range (various other model
ranges available)
-
Complete ISO calibration certificate
(optional)
-
Top-quality, high-tech TEFLON coated Gold
elements
-
High-tech Radom with a modern, aesthetic
design
-
Freely align able polarization
-
Calibration data can be saved and read-back
from an IC
within the antenna
-
Excellent forward / backward ratio
-
Excellent symmetry of radiation patterns
-
Integrated 5/8" tripod socket
-
Suitable for mobile use
-
Suitable for outdoor installation
-
Robust, splash proof design
-
Small, lightweight design
- Well suited for EMC measurements with spectrum analyzers
Antenna package includes:
- HyperLOG
antenna
- Standard
calibration data (model specific, in
10MHz steps)
- Aluminum
carrying case with custom padding
- Detachable
pistol-grip handle which converts into a
mini-tripod stand
- Sturdy,
multi-purpose aluminum tripod with
spirit-level
- Special SMA tool with over-torque
protection
|
| |
| |
Kaltman Creations LLC
|
Hyperlog 60180
|
Kaltman Creations Hyperlog 60180 680 MHz-18 GHz EMC Antennas
|
$4,194.00
|
|
|
Kaltman Creations Hyperlog 60180 680 MHz-18 GHz EMC Antennas Kaltman Creations
Hyperlog 60180 680 MHz-18 GHz EMC Antennas Rental and lease options are available please call Look at the Price!
One of the main advantages of the these antennas is that they
are not "naked" (directly exposed to the atmospheric elements). The antenna
houses their gold plated, Teflon elements in a specially constructed, high
technology Radom housing. This Radom housing was designed in such a way that its
shape, material and special coating have virtually no influence on measurements;
not even in the case of dew or humidity collection on the surface. And of course
the Radom housing helps to prevent oxidation, fissures, and general physical
damage.
Professional broadband measurement antennas have one distinct
disadvantage, they are extremely expensive. The HyperLOG® series of antennas
offers a cost-effective alternative while maintaining above industry
specifications and standards. Whatever your antenna needs - point to point
communication, fixed receiving, voice, data, machine control, or for use with
Spectran RF Spectrum Analyzers - the HyperLOG antennas represents a true cost
effective alternative!
Features
- Only one single broadband antenna is
required for the 380MHz to 18GHz frequency range (various other model
ranges available)
-
Complete ISO calibration certificate
(optional)
-
Top-quality, high-tech TEFLON coated Gold
elements
-
High-tech Radom with a modern, aesthetic
design
-
Freely align able polarization
-
Calibration data can be saved and read-back
from an IC
within the antenna
-
Excellent forward / backward ratio
-
Excellent symmetry of radiation patterns
-
Integrated 5/8" tripod socket
-
Suitable for mobile use
-
Suitable for outdoor installation
-
Robust, splash proof design
-
Small, lightweight design
- Well suited for EMC measurements with spectrum analyzers
Antenna package includes:
- HyperLOG
antenna
- Standard
calibration data (model specific, in
10MHz steps)
- Aluminum
carrying case with custom padding
- Detachable
pistol-grip handle which converts into a
mini-tripod stand
- Sturdy,
multi-purpose aluminum tripod with
spirit-level
- Special SMA tool with over-torque
protection
|
| |
| |
Kaltman Creations LLC
|
Hyperlog 7060
|
Kaltman Creations Hyperlog 7060 700 MHz-6 GHz EMC Antennas
|
$840.00
|
|
|
Kaltman Creations Hyperlog 7060 700 MHz-6 GHz EMC Antennas Kaltman Creations
Hyperlog 7060 700 MHz-6 GHz EMC Antennas Rental and lease options are available please call Look at the Price!
One of the main advantages of the these antennas is that they
are not "naked" (directly exposed to the atmospheric elements). The antenna
houses their gold plated, Teflon elements in a specially constructed, high
technology Radom housing. This Radom housing was designed in such a way that its
shape, material and special coating have virtually no influence on measurements;
not even in the case of dew or humidity collection on the surface. And of course
the Radom housing helps to prevent oxidation, fissures, and general physical
damage.
Professional broadband measurement antennas have one distinct
disadvantage, they are extremely expensive. The HyperLOG® series of antennas
offers a cost-effective alternative while maintaining above industry
specifications and standards. Whatever your antenna needs - point to point
communication, fixed receiving, voice, data, machine control, or for use with
Spectran RF Spectrum Analyzers - the HyperLOG antennas represents a true cost
effective alternative!
Features
- Only one single broadband antenna is
required for the 380MHz to 18GHz frequency range (various other model
ranges available)
-
Complete ISO calibration certificate
(optional)
-
Top-quality, high-tech TEFLON coated Gold
elements
-
High-tech Radom with a modern, aesthetic
design
-
Freely align able polarization
-
Calibration data can be saved and read-back
from an IC
within the antenna
-
Excellent forward / backward ratio
-
Excellent symmetry of radiation patterns
-
Integrated 5/8" tripod socket
-
Suitable for mobile use
-
Suitable for outdoor installation
-
Robust, splash proof design
-
Small, lightweight design
- Well suited for EMC measurements with spectrum analyzers
Antenna package includes:
- HyperLOG
antenna
- Standard
calibration data (model specific, in
10MHz steps)
- Aluminum
carrying case with custom padding
- Detachable
pistol-grip handle which converts into a
mini-tripod stand
- Sturdy,
multi-purpose aluminum tripod with
spirit-level
- Special SMA tool with over-torque
protection
|
| |
| |
Kaltman Creations LLC
|
NF3010
|
Kaltman Creations NF3010 10 Hz-400 KHz EMF Field Analyzer
|
$840.00
|
|
|
Kaltman Creations NF3010 10 Hz-400 KHz EMF Field Analyzer Kaltman Creations NF3010 10 Hz-400 KHz EMF Field Analyzer Rental and lease options are available please call Look at the Price!
Measurement of electric and magnetic fields in this price range has never been this PROFESSIONAL. Find radiation sources in your surroundings. Find their respective frequencies and signal strengths, including direct display of exposure limits. This used to be impossible in this price category, professional units often costing several thousand euros and being excessively complicated in handling. The highly complex calculations in spectrum analysis incl. exposure limit calculation is being performed, unnoticed in the background, by a high-performance DSP (digital signal processor). Exposure limit calculation used to be a complex and awkward procedure even for the professional, as most of the time, a chaotic mixture of an abundance of different frequencies, modulations and signal strengths is present. The indispensible, highly complex calculation of frequency-dependant exposure limits can ONLY be performed CONFORMING TO STANDARDS by a spectrum analyser with high-performance software. Not a problem for SPECTRAN® units: They can calculate even several authoritative exposure limits, precautionary limits and recommendations at lightning speed (simply selectable via a button) and display these overruns as a practical bargraph display (including convergence display in percent!), while the measurement is running. For achieving this, often thousands of complex calculations have to be performed per second, and a steady scan of the entire frequency range needs to be performed. A true nightmare for every processor. In our test case, the graphic display shows an approximation towards the ICNIRP limit by 6,06%. You can even cover the total ICNIRP-banwidth (depending on frequency). Hence, even the novice can perform exposure limit calculations ACCORDING TO STANDARDS without having to use complex tables and calculators. It really can't get any simpler. Features - Big graphics display (pixel display) with 51x25 pixels (can be used for complex spectrum and exposure limit display, convenient menu navigation, etc.)
- HUGE numeric display (4 digits, max. 9999)
- Large, high-resolution bargraph (50 segments) for very responsive trend display
- Various function and mode indication display blocks (AUDIO, MODE, MEMORY etc.)
- Large multi-function text display (6 text fields / e.g. for displaying units, service information, etc.)
- Three further big numeric displays (4 digits each, each max. 9999 / e.g. for simultaneous display of MIN, MAX, AVG values, 3 marker values, etc.)
- Triple multi-function text displays (Next to each of the previously described numeric displays / 3x3 text fields each / used e.g. for unit display for markers, etc.)
- Three more multi-function text displays (directly beneith the previously described displays / 3x6 text fields each / e.g. ADDITIONAL values AND unit display for markers, etc.)
- Battery status and charging display (incl. "CHARGING" and "LOW")
- 6 numerical displays for flexible bargraph scaling (incl. multiplication factor and percentage display)
|
| |
| |
Kaltman Creations LLC
|
NF5010
|
Kaltman Creations NF5010 10 Hz-1 MHz EMF Field Analyzer
|
$843.00
|
|
|
Kaltman Creations NF5010 10 Hz-1 MHz EMF Field Analyzer Kaltman Creations NF5010 10 Hz-1
MHz EMF Field Analyzer Rental and lease options are available please call Look at the Price!
Measurement of electric and magnetic fields in this price range has never been this PROFESSIONAL. Find radiation sources in your surroundings. Find their respective frequencies and signal strengths, including direct display of exposure limits. This used to be impossible in this price category, professional units often costing several thousand euros and being excessively complicated in handling. The highly complex calculations in spectrum analysis incl. exposure limit calculation is being performed, unnoticed in the background, by a high-performance DSP (digital signal processor). Exposure limit calculation used to be a complex and awkward procedure even for the professional, as most of the time, a chaotic mixture of an abundance of different frequencies, modulations and signal strengths is present. The indispensible, highly complex calculation of frequency-dependant exposure limits can ONLY be performed CONFORMING TO STANDARDS by a spectrum analyser with high-performance software. Not a problem for SPECTRAN® units: They can calculate even several authoritative exposure limits, precautionary limits and recommendations at lightning speed (simply selectable via a button) and display these overruns as a practical bargraph display (including convergence display in percent!), while the measurement is running. For achieving this, often thousands of complex calculations have to be performed per second, and a steady scan of the entire frequency range needs to be performed. A true nightmare for every processor. In our test case, the graphic display shows an approximation towards the ICNIRP limit by 6,06%. You can even cover the total ICNIRP-banwidth (depending on frequency). Hence, even the novice can perform exposure limit calculations ACCORDING TO STANDARDS without having to use complex tables and calculators. It really can't get any simpler. Features - Big graphics display (pixel display) with 51x25 pixels (can be used for complex spectrum and exposure limit display, convenient menu navigation, etc.)
- HUGE numeric display (4 digits, max. 9999)
- Large, high-resolution bargraph (50 segments) for very responsive trend display
- Various function and mode indication display blocks (AUDIO, MODE, MEMORY etc.)
- Large multi-function text display (6 text fields / e.g. for displaying units, service information, etc.)
- Three further big numeric displays (4 digits each, each max. 9999 / e.g. for simultaneous display of MIN, MAX, AVG values, 3 marker values, etc.)
- Triple multi-function text displays (Next to each of the previously described numeric displays / 3x3 text fields each / used e.g. for unit display for markers, etc.)
- Three more multi-function text displays (directly beneith the previously described displays / 3x6 text fields each / e.g. ADDITIONAL values AND unit display for markers, etc.)
- Battery status and charging display (incl. "CHARGING" and "LOW")
- 6 numerical displays for flexible bargraph scaling (incl. multiplication factor and percentage display)
|
| |
| |
Lecroy
|
OE425
|
Lecroy OE425 Multimode Optical to Electrical Converter
|
Contact Sales
|
|
|
Lecroy OE455 Multimode Optical to Electrical Converter
Lecroy OE425 Multimode Optical to Electrical
Converter
Rent me for $250 a month
Specifications
¿ Frequency range to 5 GHz (6 GHz optical) ¿ 62.5 µm multi-mode fiber
input ¿ Broad wavelength range 500 nm ¿ 870 nm ¿ High responsivity: 1.1 V/mW ¿ Low noise: 1.1 µW rms
These wide-band multi-mode optical to-electrical converters are designed for
measuring optical communications signals. Their broad wavelength range and
multimode input optics make these devices ideal for applications including
Gigabit Ethernet and Fibrechannel, as well as SONET/SDH up to 2.5 Gb/s. The
OE425 and OE455 are ProBus
modules compatible with WavePro and Waverunner oscilloscopes as well as
WaveMaster instruments when used with a LPA-BNC adapter. The OE525 and OE555 are
ProLink
modules compatible with WaveMaster, SDA and DDA instruments.
Universal Calibrated Reference Receivers
The O/E converters contain calibration data that can
be used to create optical reference receivers for SONET/SDH (up to OC48/STM16),
Fibre Channel, Gigabit Ethernet and other optical standards. This feature is
available when the O/E is used on a WaveMaster series oscilloscope. This
universal reference receiver supports any data rate up to 3 GHz and
remains calibrated on any channel of any WaveMaster.
|
| |
| |
Lecroy
|
OE455
|
Lecroy OE455 Multimode Optical to Electrical Converter
|
$2,995.00
|
|
|
Lecroy OE455 Multimode Optical to Electrical Converter
Lecroy OE455 Multimode Optical to Electrical
Converter
Rent me for $250 a month
Specifications
¿ Frequency range to 5 GHz (6 GHz optical) ¿ 62.5 µm multi-mode fiber
input ¿ Broad wavelength range 950 nm ¿ 1630 nm ¿ High responsivity: 1.1 V/mW ¿ Low noise: 1.1 µW rms
These wide-band multi-mode optical to-electrical converters are designed for
measuring optical communications signals. Their broad wavelength range and
multimode input optics make these devices ideal for applications including
Gigabit Ethernet and Fibrechannel, as well as SONET/SDH up to 2.5 Gb/s. The
OE425 and OE455 are ProBus
modules compatible with WavePro and Waverunner oscilloscopes as well as
WaveMaster instruments when used with a LPA-BNC adapter. The OE525 and OE555 are
ProLink
modules compatible with WaveMaster, SDA and DDA instruments.
Universal Calibrated Reference Receivers
The O/E converters contain calibration data that can
be used to create optical reference receivers for SONET/SDH (up to OC48/STM16),
Fibre Channel, Gigabit Ethernet and other optical standards. This feature is
available when the O/E is used on a WaveMaster series oscilloscope. This
universal reference receiver supports any data rate up to 3 GHz and
remains calibrated on any channel of any WaveMaster.
|
| |
| |
Lecroy
|
TF-USB
|
Lecroy TF-USB USB Test Fixture
|
Contact Sales
|
|
|
New Page 1
Lecroy TF-USB USB Test Fixture
Rent me for $150 a month
Features sections for signal quality, inrush, droop,
sensitivity, and disconnect. Supports full, low and high speed tests.
The USB test fixture (TF-USB) is required to perform compliance tests. The
fixture consists of several sections designed to allow connection to the
electrical signal under test. Each section is marked on the fixture, and the
ports on each section are also labeled. The section and port(s) to use for a
given test are called out in the procedure on the instrument display. To
operate, the fixture requires a 5 V power supply, which is provided with the
fixture. The USB test fixture has square pins that provide connection points for
differential and single-ended probes. The pins are connected to the ¿+¿ and ¿-¿
signal lines and a pair of ground pins are also provided.The
software and fixture combine to perform the following measurements for USB2.0
hosts, hubs, and devices. No software comes with the text fixture.
Host tests
Device tests
-
HS signal quality
-
HS Far-end for tethered devices
-
HS Near-end for untethered devices
-
HS packet parameters
-
HS chirp timing
-
HS suspend/resume/reset
-
HS Receiver Sensitivity
-
FS upstream signal quality
-
LS upstream signal quality (USB 1.1 devices only)
-
Inrush current.
|
| |
| |
Madell
|
AZ530-E
|
Madell AZ530-E E Field Monopole Probe
|
$238.00
|
|
|
Madell AZ530-E E Field Monopole Probe
Among the three Madell probes the E field monopole probe has the highest
sensitivity. It is high enough to be used as an antenna to receive radio or TV
signals. It can be used to test circuit or equipment radiation leakage.
RFI filters can be evaluated with this probe. The E field probe can also be used
for related measurements of compliance testing. Makes it easier to pass the
certification process.
Impedance is 50 ohms. The maximum frequency is 1 Ghz
|
| |
| |
Madell
|
AZ-350H
|
Madell AZ530-H High Impedance Probe
|
$225.00
|
|
|
Madell AZ530-H High Impedance Probe
This is a high impedance probe can
directly contact joint points or routes on printed circuit boards to test for RF
interference (RFI). The probe has very high resistance (similar to insulation
resistance value of PCB) and only 2pF load to the testing point (80 ohms at
1GHz) so it can directly contact the circuit without influence to the circuit.
It can be used to measure the
effectiveness of metal shielding. The individual pins of IC can be considered as
RFI sources. This probe can be used to trace the problem positions on PCB. With
this high impedance probe, the circuit can be connected to 50 ohm input of a
spectrum analyzer directly. The maximum frequency is 1 Ghz.
|
| |
| |
Madell
|
AZ-530M
|
Madell AZ530-M Magnetic Field Probe
|
$235.00
|
|
|
Madell AZ530-M Magnetic Field Probe
This magnetic field probe gives a voltage
result of the value of the magnetic field strength. This probe can be used to
find RF interference sources, detect cable leak areas or wire conduct
interference, and determine the effect of metal shielding.
50Ω input impedance. Frequency range to 1 Ghz
|
| |
| |
Tektronix
|
|
Tektronix A6304XL
|
Contact Sales
|
|
|
Tektronix
A6304XL
- 8 Meter Cable
- 500 Amps Continuous/700 Amps Peak
- DC to 2 MHz
Applications
- Motor Drives
- Satellite Systems
- Inverters
- Transportation Systems
- Power Supplies
- Avionics
|
| |
| |
Tektronix
|
P6247
|
Tektronix 1 Ghz Differential P6247 Probe
|
$1,995.00
|
|
|
Tektronix 1 Ghz P6247 Probe
Tektronix P6247 1 Ghz Differential Probe
Rent
me for $200 a month
The P6248, P6247 and P6246 enable users to make time domain or frequency
domain measurements on high-bandwidth signals commonly found in disk drive,
digital IC design (RAMBUS) and communication applications (Gigabit Ethernet,
IEEE-1394 Firewire and Fibre Channel). The P6248 includes accessories that
allow RAMBUS via probing and IEEE-1394 interconnect access. The small probe
head geometry and assorted probe tip accessories allow these probes to
easily accommodate manual probing of surface mount devices while maintaining
high CMRR. The P6246, P6247 and P6248 are ideal
for design verification of disk drive read, channel electronics and timing
analysis for troubleshooting ground bounce problems associated with
high-speed logic. They can also be used for pulse shape or cross talk
compliance testing of highspeed communication signals.
Description
- 1.7 GHz (Typical Probe Only <27°C) 1X Mode
- 1.5 GHz Bandwidth (Guaranteed)
- 1.85 GHz (Typical Probe Only
<27°C) 10X Mode
- For use with Tek oscilloscopes w/TEKPROBE II
interface
- Square Pin Receptacle (Female)
- Electrostatic
Discharge Tolerant
- >60db(1000:) CMRR
Characteristics Bandwidth
(guaranteed) P6248: DC to 1.5 GHz.
P6247: DC to 1.0 GHz. P6246: DC to 400
MHz. Rise Time (specified) ¿ <265 ps
(P6248), <350 ps (P6247), <875 ps (P6246).
DC Attenuation Accuracy ¿ ±2%. Common
Input Voltage Range ¿ ±7.0 V, 1X; ±7.0 V, 10X.
Differential Input Voltage Range ¿ ±850 mV, 1X; ±8.5 V, 10X.
Max. Nondestruct Input Voltage ¿ ±25 V (DC + peak AC).
Electrostatic Immunity ¿ >15 kV.
TEKPROBE® Interface ¿ Probe power, autoscaling, auto-termination with TDS
oscilloscopes. Bandwidth Limit ¿ Switchable, 200 MHz
(P6246 and P6247). DC Reject ¿ 0.4 Hz, 1X; 4.0 Hz, 10X (P6246 and P6247).
Typical Specifications
Input C
Input R
|
| |
| |
Tektronix
|
Tektronix Fiber Optic Cable
|
Tektronix 200 Meter Fiber Optic Cable
|
Contact Sales
|
|
|
Tektronix A69T06 Fiber Optic Transmitter
Tektronix 200 Meter Fiber Optic Cable
Part
of the Discontinued A6906S System
This is the Fiber Optic Cable that
goes with the A69T06 that is the transmitter for
the A6906S System. It is used to link the transmitter and the receiver together. We have a system that was separated and are selling the
individual items of the A6906S set.
|
| |
| |
Tektronix
|
A6303
|
Tektronix A6303 15 MHZ AC/DC CURRENT PROBE
|
Contact Sales
|
|
|
Tektronix A6303
Description:
The A6312, A6302 and A6303 offer a wide range of current measurement capability for the lab and bench environment. The A6312 covers frequencies from DC to 100 MHz while the A6302 covers DC to 50 MHz. Both clip onto conductors up to 3.81 mm (0.15 in.) and measure continuous currents up to 20 A and peak currents up to 50 A as long as they do not exceed the amp*second product of 100 A'ps. The larger A6303 measures 20A continuous/500A peak, DC-15Mhz, 2 meter cable, measures upto (21.1mm) 0.83in. dia conductor.
|
| |
| |
Tektronix
|
A69B04
|
Tektronix A69B04 Battery Pack
|
Contact Sales
|
|
|
Tektronix A69B04 Battery Pack
Tektronix A69B04 Battery Pack
Part
of the Discontinued A6906S System
The A69B04 is the battery charger
for the A6906S System. We have a system that was separated and are selling the
individual items of the A6906S set. It is a slightly older version of the
A69C04.
|
| |
| |
Tektronix
|
A69T06
|
Tektronix A69T06 Fiber Optic Transmitter
|
Contact Sales
|
|
|
Tektronix A69T06 Fiber Optic Transmitter
Tektronix A69T06 Fiber Optic Transmitter
Part
of the Discontinued A6906S System
The A69T06 is the transmitter for
the A6906S System. We have a system that was separated and are selling the
individual items of the A6906S set. The
A69T06 Transmitter is an electrical-to-optical (E/O) converter; it converts an
input electrical signal into an optical signal. System gain is controlled by an
attenuator that is set in a 1¿2¿5 sequence. The A69T06 is also provided with a
variable-gain amplifier for self-calibration to maintain measurement precision.
The A69T06 is powered by an internal sealed rechargeable lead-acid battery pack.
The A69T06 Transmitter is powered from a battery
pack. To charge the battery pack, you need to remove it from the A69T06
Transmitter. It takes 12 hours to charge a battery pack that has been fully
discharged. You cannot use a battery pack to power the A6906S while the battery
pack is charging, but you can use a second battery pack to operate the A69T06
while charging a battery pack using the A69C06.
|
| |
| |
Tektronix
|
|
Tektronix AM503 Current Probe Amplifier
|
Contact Sales
|
|
|
New Page 1
Tektronix AM503
Description :
Tektronix AM503 The AM503 Current Probe Amplifier allows display of current on any oscilloscope having 10 mV/div sensitivity, 50 ohm or 1 Mohm input.
|
| |
| |
Tektronix
|
AM503B
|
Tektronix AM503B Current Probe Amplifier
|
Contact Sales
|
|
|
Tektronix AM503B Current Probe Amplifier
Tektronix AM503B Current Probe Amplifier
Rent me for $100 a month
Require additional probe, power module and
oscilloscope
The AM503B amplifier is the heart of the AM503S measurement
system. All functions are microprocessor controlled, providing significant
improvement in ease of use and functionality. A single pushbutton controls
degauss and auto-balance functions. An additional significant improvement is
that individual A6302/A6303 probes no longer need to be calibrated with a
specific amplifier, but can be interchanged between AM503Bs. The AM503B
supports the new XL Series of current probes. (The AM503 and AM503A do not
support the XL Series) Requires one slot in TM500 or TM5000 series mainframes. The AM503S Current Probe System is the most versatile current
measurement system available. Since the probes incorporate both a transformer
and a Hall Effect device, broadband AC/DC current can be measured
simultaneously. Depending on the probe used, current from DC to 100 MHz and up
to 700 A can be measured by clipping the split-core probes around the conductor.
The AM503S is truly a system, consisting of an AM503B Current Probe Amplifier, a
TM502A two-wide Power Module and an A6302 Current Probe.
Features
- Manual Current Probe Amplifier
- Push Button Auto Balance/Degauss
- Bright LED Current/Division Display
- Plugs into TM500/5000 Power Modules
- AC/DC Measurements
- With A6302 Probe:
- DC to 50 MHz
- 20 A Continuous/50 A Peak
- Max. Conductor Diameter: 0.15 in.
- With A6303 Probe:
- DC to 15 MHz
- 100 A Continuous/500 A Peak
- Max. Conductor Diameter: 0.83 in.
- With A6304XL Probe:
- DC to 2 MHz
- 500 A Continuous/700 A Peak
- Max. Conductor Diameter: 0.83 in.
- With A6312 Probe:
- DC to 100 MHz
- 20 A Continuous/50 A Peak
- Max. Conductor Diameter: 0.15 in.
|
| |
| |
Tektronix
|
CT-4
|
Tektronix CT-4 Current Probe
|
Contact Sales
|
|
|
Tektronix CT-4 Current Probe
Tektronix CT-4 Current Probe
Rent me for $150 a month
The CT4 is a robust clip-on high current transformer that extends the
measurement capability of the P6021, A6302/XL, A6302, A6312 and TCP202 clip-on
current probes. Maximum low frequency performance down to 0.5 Hz is obtained
using the AM 503S. Current amplitudes to 20,000 A may be measured using the
A6302/XL, P6021, A6302, A6312 or TCP202 (with passive termination), provided the
amp*second ratings are not exceeded.
The CT4 may be used with the P6021 for measurements at normal line frequency
and above. (The P6022 and A6303 are not compatible with the CT4.)
The CT4 has receptacles for current probes in either 20:1 or 1000:1 step-down
ratios.
The 1.5 in. square split-core opening makes it possible to clip onto large
conductors without breaking the circuit under test. Insulated core and shield
assemblies allow measurements on bare wires to 3000 VP (1000 VRMS
CAT III) and to 14 kV with the included high voltage bushing.
|
| |
| |
Tektronix
|
P2221
|
Tektronix P2221 X10 200 MHz Oscilloscope Probe
|
Contact Sales
|
|
|
Tektronix P2221 X10 200 MHz Oscilloscope Probe
Tektronix P2221 X10 200 MHz Oscilloscope Probe
The Tektronix P2221 200 MHz passive voltage probes permit
selection of 1x or 10x attenuation, using a switch located on the probe head.
The P2220 probe is compatible with TDS200, TDS1000, TDS1000B,
TDS2000, TDS2000B, and TPS2000 Series oscilloscopes. The P2220 probe also
provides floating measurement capability up to 30 VRMS with TPS2000
Series oscilloscopes only. (Note: Do not float with TDS2000, TDS2000B, TDS1000,
TDS1000B, or TDS200 Series oscilloscopes.) The P2221 is compatible with MSO2000
and DPO2000 Series oscilloscopes.
Features
- 1x/10x Attenuation
- 200 MHz Bandwidth
- 1.5 m Length
- UL3111-1, CSA1010.1, EN61010-1, EN61010-2-031, and
IEC61010-2-031
Applications
- Relative Low-frequency Measurements
- Low-frequency Computer and Telecom Measurements
- Power Supplies
- Low-frequency Amplifiers
Characteristics
10x Position
-
Bandwidth
DC to 200 MHz
-
Probe Length
1.5 m
-
Attenuation Ratio
10:1
-
Compensation Range
10 to 25 pF
-
Input Capacitance
P2221: 17.0 pF (typ)Input
Resistance
10 MΩ
-
Maximum Input Voltage
300 V CAT II
-
Maximum Voltage Between Reference Lead and
Earth Ground
30 VRMS
1x Position
-
Bandwidth
DC to 6 MHz
-
Probe Length
1.5 m
-
Attenuation Ratio
1:1
-
Compensation Range
All oscilloscopes with
1 MΩ input
-
Input Capacitance
110 pF (typ)
-
Input Resistance
1 MΩ
-
Maximum Input Voltage
150 V CATII
-
Maximum Voltage Between Reference Lead and
Earth Ground
30 VRMS
|
| |
| |
Tektronix
|
P5100
|
Tektronix P5100 High Voltage Probe
|
$215.00
|
|
|
Tektronix P5100 High Voltage Probe
Features
- DC to 250 MHz
- 1000V CAT III (2500 V DC + Peak AC)
- 100X with Readout Coding
- UL3111-1, EN61010-1, IEC61010-2-031, CSA1010.1, CSA1010.2.031
- 7-30 pF Compensation Range
Applications
- Power Supply Design
- Design Motor Drive
- Electronic Ballast
- Power Semiconductors
- Switch Mode Control
- UPS Systems
- Power Converters
P5100 High Voltage Probe
The P5100 is a low-input capacitance High Voltage Probe (2.5 kV)
designed for higher frequency applications. The probe can be compensated to
match plug-ins and oscilloscopes with nominal input capacitances of 7-30 pF.
A variety of screw-on accessories provide easy connection to the device under
test.
|
Probe
|
Nominal Length
|
Attenuation
|
Bandwidth
|
Risetime (typical)
|
Loading
|
Max. Input V DC or RMS
|
Max. Float V
|
Comp. Range in pF
|
Readout
|
|
P5100
|
10 ft.
|
100X
|
250 MHz
|
1.75 ns
|
10 MΩ/ 2.75 pF
|
2.5 kV (DC + Pk AC) 1,000 V CAT III
|
N/A
|
7 to 30
|
Yes
|
|
| |
| |
Tektronix
|
P5102
|
Tektronix P5102 High Voltage Probe
|
$215.00
|
|
|
Tektronix P5102 High Voltage Probe
Features P5102 - for THS700 Series
- 100 MHz Bandwidth
- Up to 1,000 VRMS
- 10X Attenuation
- Safety UL 3111-1, IEC 61010-2-031, CSA 1010.1, CSA 1010.2.031,
EN61010-2-031
Applications
- Power Supply Design
- Design Motor Drive
- Electronic Ballast
- Power Semiconductors
- Switch Mode Control
- UPS Systems
- Power Converters
In many applications, it is important to be able to isolate the measurement
from earth ground and also to isolate the common voltage between channels. With
the P5102 and the THS700 Series handheld digital storage oscilloscopes, you have
not only the isolation for the measurement from earth ground, but you also have
full isolation between the two channels. The P5102 was designed to give you 600 V
CATII (float) isolated channel performance for up to 1000 V AC RMS
CATII on the 100 MHz probe. A variety of screw-on accessories provides easy
connection to the device under test.
Characteristics
Nominal Length - 2 m.
Attenuation - 10X.
Bandwidth - 100 MHz.
Rise Time - ≤3.5 ns.
Loading - 5 MΩ/11.2 pF.
Max Input V - 1000 V AC RMS, CAT II.
Max Float - 600 V AC RMS, CAT II.
Compensation Range - 24 to 28 pF
|
| |
| |
Tektronix
|
P5205
|
Tektronix P5205 High Voltage Differential Probe
|
Contact Sales
|
|
|
Tektronix P5205 High Voltage Differential
Probe
The P5205 is a 100 MHz Active Differential Probe capable of measuring
fast rise times of signals in floating circuits. This 1,300 V differential
probe can measure safely voltages in IGBT circuits such as motor drives
or power converters. It is specifically designed to operate on Tektronix
oscilloscopes with TEKPROBE® interface.
Features
- Bandwidth up to 100 MHz
- Up to 1,300 V Differential (DC + pk AC)
- Overrange Indicator
- Safety Certified
- Switchable Attenuation
- Switchable Bandwidth Limit
Applications
- Floating Measurements
- Switching Power Supply Design
- Motor Drive Design
- Electronic Ballast Design
- CRT Display Design
- Power Converter Design and Service
- Power Device Evaluation
|
Specifications
|
|
P5205
|
|
|
Bandwidth (-3 dB)
|
|
100 MHz
|
|
|
Differential Mode Voltage (RMS or DC) (between positive and negative
input leads)
|
|
1000 V CAT II
|
|
|
Differential Mode Voltage (Peak)*1 (between positive and
negative input leads)
|
|
1300 V
|
|
|
Common Mode Voltage (RMS or DC + Pk AC) (between positive lead and
ground or negative lead and ground)
|
|
1000 V CAT II
600 V CAT III
|
|
|
Attenuation (switchable)
|
|
50X/500X
|
|
|
CMRR @ 60 Hz/1 MHz (typical)
|
|
80 dB/50 dB
|
|
|
| |
| |
Tektronix
|
P5210
|
Tektronix P5210 High Voltage Differential Probe
|
Contact Sales
|
|
|
Tektronix P5210 High Voltage Differential Probe
Tektronix P5210 High Voltage Differential Probe
Rent me for $150 a month
The Tektronix P5210 is a Differential Probe that is capable of
measuring floating voltages up to 5,600 V (DC + peak AC) safely and has a
bandwidth up to 50 MHz. It is supplied with two sizes of hook tips and has an
over range visual and audible indicator which warns the user when they are
exceeding the linear range of the probe. Can be used with any Tektronix TEKPROBE
interface oscilloscopes directly or with any oscilloscope with the use of the
1103 TEKPROBE Power Supply. Please check your oscilloscopes operating manual.
Tektronix models TDS7154B, TDS7254B, TDS7404B, TDS6404, TDS6604, CSA7154, and
CSA7404B require a TCA-1MEG Buffer Amplifier
Features
- Maximum Differential Input Voltage 5.6 kV (DC + peak
AC)
- 50 MHz Bandwidth
- Probe Connects Directly to TDS Scope through
TekProbe Interface
- Double Insulated Probe Head
- Easy Connection to Power Devices, Discrete
Components, and Bus Bars
- Make Safe Floating Measurements with Grounded Scope
- Safety Certified
Applications
- Floating Measurements
- Switching Power Supply Design
- Motor Drive Design
- Electronic Ballast Design
- CRT Display Design
- Power Converter Design and Service
- Power Device Evaluation
The Tektronix P5210 can be used with any
oscilloscope and enables users to safely make measurements of floating circuits
with their oscilloscope grounded. The P5210 Active Differential Probe converts
floating signals to low-voltage ground referenced signals that can be displayed
safely and easily on any ground referenced oscilloscope. WARNING: For safe
operation, do not use the P5210 High Voltage Differential Probe with
oscilloscopes that have floating inputs (isolated inputs), such as the Tektronix
TPS2000 Series oscilloscopes and THS700 Series oscilloscopes. The P5210 High
Voltage Differential Probe requires an oscilloscope or other measurement
instrument with grounded inputs. The P5210 is a Differential Probe that is
capable of measuring floating voltages up to 5,600 V (DC +pk AC) safely and has
a bandwidth up to 50 MHz. It is supplied with two sizes of hook tips and has an
over range visual and audible indicator which warns the user when they are
exceeding the linear range of the probe.
|
| |
| |
Tektronix
|
P6015A
|
Tektronix P6015A 40 KV Oscilloscope Probe
|
$1,195.00
|
|
|
Tektronix P6015A 40 KV Oscilloscope Probe
Tektronix P6015A 40 KV Oscilloscope Probe
Rent me for $250 a month
Features
- High Voltage - 20 kV DC/40 kV Peak (100 ms Pulse Width)
- High Bandwidth - 75 MHz
- Silicone Dielectric
- Optional 1,000X Coding
- Wide Compensation Range (7-49 pF)
- Heavy Duty Versatile Ground Lead and Clip
For heavy-duty high-performance measurements of voltages over
2.5 kV, the P6015A is the industry standard. You can measure DC voltages up to
20 kV and pulses up to 40 kV. The 75 MHz bandwidth enables you to capture fast,
high-voltage signals.
The P6015A uses an environmentally safe silicone compound for a
dielectric and never needs refilling. Other features include: A 7-49 pF
compensation range, small compensation boxes which fit on adjacent amplifier
inputs and a readout option for use with Tektronix digital scopes. With the
readout option, displayed voltage amplitude values will be the actual signal
value rather than understated by a factor of 1,000. Using the readout version
with other than Tektronix digital scopes may result in an erroneous readout
display.
|
| |
| |
Tektronix
|
P6046
|
Tektronix P6046 Differential Probe
|
Contact Sales
|
|
|
Tektronix P6046 Differential Probe
Tektronix
P6046 Differential Probe
The Tektronix P6046 is a self-contained active differential
system consisting of a differential probe, amplifier and power supply. Active
FET amplifiers at the dual-inputs reduce circuit loading. Combined with the
differential processing occuring in the probe head, the P6046 provides superior
common mode rejection ratios (CMRR) at high frequencies typically 10,000:1 out
to 50 kHz, derating to 5,000:1 at 1 MHz. Since the P6046 is self-contained, it
provides a differential output into a single oscilloscope channel. System
controls enable you to select AC or DC coupling, adjust the DC balance and
select mV/div from 1 to 200mV (10mV to 2V with attenuator head) in standard
1,2,5 steps. A slip-on 10X attenuator is also included which increases the
maximum input voltage from +/-25V to +/-250V and the common mode dynamic range
from +/-5V to +/-50V.
Features
- CMRR -
With deflection
factors of 1 to 20 mV/div: at least 10,000: 1 at 50 kHz,
5000: 1 at 1 MHz, and 1000: 1 at 50 MHz (DC coupled).
- Common Mode Linear Dynamic Range
-
±5 V, ±50 V with 10x attenuator
- Bandwidth -
DC to 100 MHz
(-3 dB)
- Rise Time -
3.5 ns or less
- Deflection Factor Range -
1 to 200 mV/div in 8 calibrated steps, 1-2-5 sequence (with
an oscilloscope deflection factor of 10 mV/div). Input RC 1
M ohm paralleled by 10 pF or less.
- Input Coupling -
AC or DC,
selected by a switch on the probe. Low frequency response
AC-coupled is -3 dB at 20 Hz, 2 Hz with 10x attenuator.
- Displayed Noise -
Typically 450 mV or less.
- Maximum Input Voltage -
±25 V (DC peak AC), ±250 V with 10x attenuation, derated
with frequency.
- Output Impedance -
50 ohms
through a BNC-connector. 50 ohm termination supplied with
amplifier for use with 1 M ohm systems.
- Probe Cable -
6 ft. long,
terminated with special nine-pin connector.
|
| |
| |
Tektronix
|
P6056
|
Tektronix P6056 X10 3.5 GHz Oscilloscope Probe
|
Contact Sales
|
|
|
Tektronix P6056 X10 3.5 GHz Oscilloscope Probe
Tektronix P6056 X10 3.5 GHz Oscilloscope Probe
The Tektronix P6056
is a miniature, fast-rise, low
input-capacitance probe with relatively constant input resistance
over a wide range of frequencies, designed for use with 50 Ω
wide-band oscilloscopes such as the Tektronix 7904 with 7A19 plug-in
installed.
Cable length for each probe is selected for calibrated signal
delay.
These probes can also be used with sampling systems by utilizing
appropriate adapters. The Tektronix P6056 probes are equipped with a special BNC connector that
provides trace identify and digital readout information when used
with plug-in units or mainframes that have these features. A button
on the Trace Shift Sleeve portion of the probe body provides the
trace identify function.
Electrical characteristics are applicable when used with an
instrument that is calibrated within an ambient temperature between
+20°C and +30°C. Unless otherwise stated, electrical characteristics
apply over and operating temperature range from -15°C to +55°C, and to
an altitude of 15,000 feet.NOTE: The following electrical specifications apply when the probe is
operating into a 50 Ω oscilloscope input or a 50 Ω termination.
ELECTRICAL
- Attenuation: (Includes ±2% Input Resistance of Oscilloscope)
,
10X within 3%
- Input Resistance: (Within 3%)
P6056, 500 Ω DC to 300 MHz, decreasing to 250 Ω at 1 GHz
- Input Capacitance:
P6056
Approximately 1 pF
- Bandwidth (-3 dB): (Calculated from Risetime)
P6056:
DC to 3.5 GHz (probe only), DC to approximately 500 MHz with
7A19 and 7904
- Risetime:
P6056: 100 ps (probe only)
- Maximum Input Voltage:
P6056: 16 V
DC or RMS (AC or pulse) to 800 MHz, decreasing to 9 V at 1 GHz
- Signal Delay Time:
P6056 and
P6057: 8.2 ns (6 ft probe), 12.3 ns (9 ft probe), each within 35 ps.
- Weight:
6 ft probe - 2 ounces, 9 ft. probe - 3 ounces (complete with
accessories, except Instruction Manual). Shipping: 6 ft probe - 12
ounces, 9 ft probe - 13 ounces.
- Dimensions: Nominally 6 ft. and 9 ft. long (Calibrated
for signal delay time)
- Environmental:
Probe will operate within specifications over the following ranges:
Temperature - From -15°C to +55°C. Altitude - To 15,000 feet..
|
| |
| |
Tektronix
|
|
Tektronix P6101
|
Contact Sales
|
|
|
Tektronix P6101
Description:
The
P6101 probe is compatible with most general purpose oscilloscopes
that have a 1 MΩ input impedance and bandwidth up to 15 MHz.
|
| |
| |
Tektronix
|
P6105A
|
Tektronix P6105A 100MHz Probes
|
Contact Sales
|
|
|
New sealed in Tek packaging, with all standard Tek accessories, Modularity Readout/Ground Reference Rugged Construction,100Mhz, 10x,2 meter, 15-35pf, 10meg input resistance, 450Vrms. |
| |
| |
Tektronix
|
P6120
|
Tektronix P6120 X10 60 MHz Oscilloscope Probe
|
Contact Sales
|
|
|
Tektronix P6120 X10 60 MHz Oscilloscope Probe
Tektronix P6120 X10 60 MHz Oscilloscope Probe
Good Basic Low Cost Probe
- 10X Passive Voltage Probe
- 10X, 10 MegOhm
- Compensator and mini tip
- 2 meters long, BNC
|
| |
| |
Tektronix
|
P6135A
|
Tektronix P6135A Differential Passive Voltage Probe Pair
|
$749.00
|
|
|
Tektronix P6135A
Differential Passive Voltage Probe Pair
Rent me for $50 a month
Features &
Benefits
- Attenuation Adjustable to 10X
- 10,000: 1 CMRR on 11A33 Differential Comparator; 20,000: 1 on
7A13 Differential Amplifier
- ±500 V Maximum Common Mode Voltage
- Matched Pair
Applications
- Power Supplies
- Disk Drives
- Electronic Ballast
- Intelligent Motion
- Adjustable Speed Drives
P6135A Differential Probe Pair
The P6135A differential probe pair is very carefully matched to
minimize differences in impedance and signal delay.
With differential amplifiers the P6135A provides CMRR ratios up to
20,000:1. Since a single 10X probe with accuracy of 1% or less gives a
scope-to-probe CMRR of no better than 50:1, the P6135A is essential to
obtain accurate results from your differential amplifier. Three pairs
of carefully matched, precision-engineered hybrid tips enable the
P6135A to be specifically matched with all Tektronix 11000, 7000 and
5000 Series differential amplifiers and comparators. It also provides
excellent performance when used with plug-in amplifiers or
oscilloscopes having input impedances of 1 MÙ/13-15 pF,
1 MÙ/18-22 pF and 1 MÙ/45-49 pF.
|
| |
| |
Tektronix
|
P6137
|
Tektronix P6137 400 MHz X10 Oscilloscope Probe
|
$200.00
|
|
|
Tektronix P6137 400 MHz X10 Oscilloscope Probe Tektronix P6137 400 MHz X10 Oscilloscope Probe The P6137 family of oscilloscope probes sets the standard for high performance passive voltage probes. Continued growth of the family paces Tektronix' new series of high performance bench top oscilloscopes, the TDS500/600/700/3000/7000 Series and high performance portable oscilloscopes and the TDS400 Series. These probes feature modular construction, HYBRID/SMT circuitry, a smaller probe head/cable assembly than traditional passive probes, 10X attenuation readout encoding and a full complement of attachment accessories. Smaller probe tips and lightweight cable assemblies allow easy negotiation of dense circuitry or tight spaces.
|
| |
| |
Tektronix
|
TEK P6138A
|
Tektronix P6138A 10X 400MHz Probe
|
$200.00
|
|
|
Tektronix
P6138A 10X 400MHz Probe
The P6138A is 10X 400MHz Modular Compact
Probe designed especially for the TDS400 series oscilloscopes. It has
an input capacitance range of 12 to 18pf and can be used with most
1Mohm input oscilloscopes.
Bandwidth (with TDS 460A or TDS 430A): 400 MHz
Bandwidth (with TDS 420A): 200 MHz
Attenuation : 10X ±1.0% at DC
Input Resistance : 10 Mohm ±1.0%
Input Capacitance : 10.0 pF ± 0.8 pF
Scope Input Resis : 1 Mohm
Compensation Range : 12pF to 18pF
Readout Pin : YES
Ground Ref : NO
ID Button : NO
Max Rated Voltage : 300 VRMS
Cable Length : 1.3 meters
Net Weight : 0.24 lb (110 g)
Scope Compatibility : TDS 400 Series
|
| |
| |
Tektronix
|
P6139A
|
Tektronix P6139A 10X Probes *NEW*
|
$250.00
|
|
|
Tektronix P6139A 10X 500 MHz Probe
Tektronix P6139A 10X 500 MHz Probe
The P6139A is a compact
high-impedance passive probe designed for use with Tektronix TDS3000 and TDS500
Series digitizing oscilloscopes. The P6139A has a 1.3 meter cable and is fully
compatible with the Tektronix family of compact size (3.5 mm) probe accessories.
Bandwidth (with TDS3054 or TDS500 series): 500 MHz
Bandwidth (with TDS3012): 100 MHz
Attenuation : 10X ±0.5% at DC
Input Resistance : 10 Mohm ±0.5%
Input Capacitance : 8.0 pF ± 0.8 pF
Scope Input Resis : 1 Mohm
Compensation Range : 8pF to 12pF
Readout Pin : YES
Ground Ref : NO
ID Button : NO
Max Rated Voltage : 400 VRMS (CAT I)
300 VRMS (CAT II)
150 VRMS (CAT III)
Cable Length : 1.3 meters
Net Weight : 0.24 lb (110 g)
Scope Compatibility : TDS 500 & TDS 3000 Series
This family of oscilloscope probes sets the standard for high
performance passive voltage probes. Continued growth of the family paces
Tektronix' new series of high performance bench top oscilloscopes, the
TDS400/500/600/700/3000B/5000/7000B Series high performance portable
oscilloscopes. These probes feature modular construction, HYBRID/SMT circuitry,
a smaller probe head/cable assembly than traditional passive probes, 10X
attenuation readout encoding and a full complement of attachment accessories.
Smaller probe tips and lightweight cable assemblies allow easy negotiation of
dense circuitry or tight spaces. The compact probe head/tip assembly is
compatible with the full line of compact accessories. When the
Subminiature/Compact-to-miniature probe tip adapter (013-0202-03) is installed
over the probe head/tip, the P5050, P6138A and P6139A probes are fully
compatible with all miniature tip accessories.
|
| |
| |
Tektronix
|
P6150
|
Tektronix P6150 50 Ohm Divider (Zo) Low Capacitance
|
Contact Sales
|
|
|
New Page 1
Tektronix P6150 50 Ω Divider (Zo)
Low Capacitance
Features
Low Impedance Zo TDR Passive Probes
- Low Capacitive Loading to Extremely High Frequencies
- Interchangeable Attenuator Tip Assemblies: 1X, 10X (P6150)
Applications
- High-speed Device Characterization in Microwave Communication, Signal
Processing and Logic Applications
- Propagation Delays for ECL, GaAs and Other Logic Circuitry and Devices
- Circuit Board Impedance Testing (TDR)
- High-speed Sampling Systems
P6150 DC to 9 GHz
The P6150 is a 9 GHz bandwidth, 10X attenuation, low impedance probe designed
for use with the SD2X family of Sampling/TDR plug-ins. The probe consists of
interchangeable, screw-in attenuator tip assemblies (1X and 10X) and an
SMA-to-SMA probe cable. An assortment of circuit and grounding attachments is
included to optimize attachment to the device under test while maintaining high
signal integrity.
|
| |
| |
Tektronix
|
|
Tektronix P6201Probe
|
Contact Sales
|
|
|
Tektronix P6201
Description:
DC-900 MHz FET Probe.
An active FET probe that provides unity gain and DC to 900 MHz bandwidth. The low probe-tip capacitance permits coupling of high-frequency signals to an oscilloscope with minimum loading on the circuit being tested. Plug-in attenuator heads provide higher input resistance and reduced input capacitance.
|
| |
| |
Tektronix
|
P6203
|
Tektronix P6203 1 Ghz Active Probe
|
$495.00
|
|
|
New Page 1
Tektronix P6203 1 Ghz Active Probe
P6203 DC to 1 GHz FET Probe
- P6203 10 kohm / 2 pF, 10X
- DC Offset
- Identify Button Allows remote Sequencing of Oscilloscope Programs
- Automatic 50 ohm Termination
- Easily Replaceable Probe Tips / Probe Heads
|
| |
| |
Tektronix
|
|
Tektronix P6204 Active FET Probe
|
Contact Sales
|
|
|
Tektronix P6204 1 Ghz 10x FET Probe
Tektronix P6204 1 Ghz 10x FET Probe
Rent me for $150 a month
The Tektronix
P6204 FET Probe is a low circuit loading signal acquisition
probes for CSA (Communications Signal Analyzers), DSA (Digitizing Signal
Analyzers), 11000 Series and the TDS Family of Oscilloscopes. The P6204
is designed with FET devices for its inputs, which allows very high
input resistance values and low input capacitances. The P6204 offers a
wide linear dynamic input range for accessing most digital device
families using today's logic voltage levels. Power for the P6204 is
supplied by the CSA, DSA, TDS and 11000 Series mainframes through the
TEKPROBE BNC Interface, eliminating the need for extra cabling and/or
external power supplies. An 1103 TEKPROBE Power Supply or a TEKPROBE
Interface is required.
Features
▪ DC to 1 GHz
▪ 1.9 picofarad Input Capacitance
▪ 10 Megaohm Input Resistance
▪ DC Offset
▪ Identify Button
▪ 1.5m w/ID and Tekprobe Connector▪
|
| |
| |
Tektronix
|
P6205
|
Tektronix P6205
|
Contact Sales
|
|
|
Tektronix P6205 Stock units have limited accy's. BW: 750Mhz, Input: 2pf/1Meg, +/-40V max, 1.5 meter.
The P6205 Probe is part of Tektronix' line of Low Circuit Loading Signal Acquisition probes for CSA (Communications Signal Analyzers), DSA (Digitizing Signal Analyzers), 11000 Series and the TDS Family of Oscilloscopes. The P6205 is designed with FET devices for its inputs, which allows very high input resistance values and low input capacitances. Both Active FET probes provide a wide linear dynamic input range for accessing most digital device families using today's logic voltage levels. Power for the P6205 is supplied by the CSA, DSA, TDS and 11000 Series mainframes through the TEKPROBE BNC Interface, eliminating the need for extra cabling and/or external power supplies. Probe information such as type, serial number, attenuation factor, offset scale factor, input resistance and termination resistance required is communicated through the TEKPROBE Interface between the Active Probe and the CSA, DSA and 11000 Series mainframes. This information is used by these oscilloscope mainframes during the scope initialization sequence and measurement analysis.
|
| |
| |
Tektronix
|
|
Tektronix P6217 4 Ghz High Impedance FET Probe
|
Contact Sales
|
|
|
Tektronix P6217 4 Ghz High Impedance FET Probe
Tektronix P6217 4 Ghz High
Impedance FET Probe
Rent me for
$200 a month
The P6217 is an active FET probe for use with Tektronix CSA (Communication
Signal Analyzers), DSA (Digitizing Signal Analyzers), 11000 Series and the
TDS500/600/700 family of oscilloscopes. Power is supplied through the
TekProbe(TM) BNC interface. It is a 10x probe and has a high input impedance of
100 kilo ohms. It uses the TEKPROBE 2 interface. Please check your oscilloscopes
manual to verify compatibility with your oscilloscope.
Features
Active FET Probe
▪ Provides a 10X attenuation
▪ 4 GHz at - 3dB bandwidth
▪ Typical input capacitance of 0.40 pF
▪ Input resistance of 100 kΩ
▪ 1.5 meters of cable length
|
| |
| |
Tektronix
|
P6243
|
Tektronix P6243
|
$649.00
|
|
|
Tektronix P6243 1
Gigahertz Active Probe
The P6243 1GHz Active FET probe is the high performance probing
solution for 500 MHz oscilloscopes. The P6243 has a bandwidth of 1 GHz
and can be used with Tektronix' full line of 500 MHz oscilloscopes. In
addition, the P6243 is powered by the TEKPROBE BNC interface,
eliminating the need for additional power supplies and cables when used
with TEKPROBE BNC oscilloscopes. The P6243 offers superior signal
acquisition on surface mount devices compared to the much higher
capacitive loading of passive probes. The P6243 has <1 pF capacitive
loading which allows it to measure high speed signals without affecting
the signal or device under test. Furthermore, the included accessories
and adapters allow for easy attachment to SMDs. Specs-Input:1GHz, 10x, 1pf/1meg, +/-15V max, <350ps risetime, 1.3 meter.
|
| |
| |
Tektronix
|
P6245
|
Tektronix P6245 1.5 GHz Active Probe
|
$1,500.00
|
|
|
Tektronix P6245 1.5 GHz Active Probe
Tektronix
P6245 1.5 GHz Active Probe
Rent me for $100 a month
The Tektronix P6245 Active FET probe achieves high-speed signal
acquisition by solving three traditional problems:
- Lower DUT loading (1 pF/1 Mohm probe loading)
- Direct and easy access to SMDs
- Access DUT signals and scope bandwidth for
TDS600/700/3000/5000/6000/7000 and CSA7000 scopes up to 1 GHz
bandwidths
The Tektronix P6245 and P6243 Active probes provide the
electrical and mechanical performance required for today's digital systems
designs. No additional power supplies or cables are required when used with
TEKPROBE BNC oscilloscopes. The P6245 achieves high-speed signal acquisition and
low circuit loading, required for solving today's problems faced by designers.
The small compact probe head and versatile attachment accessories allow direct
connection to the device under test.
The Tektronix P6245 Active Probe provides scope bandwidth at the
probe tip for the TDS500/600/700 and any other Tektronix Oscilloscope with a
TEKPROBE interface. A Tektronix 1103 interface may be used for instruments
without the TEKPROBE interface.
- 1.5 GHz Bandwidth (Typical, Probe Only)
- 1 pF Input Capacitance
- 1 Mohm Input Resistance
- Direct Access to SMDs as Small as 0.5 mm Pitch
- Measures CMOS, BiCMOS, ECL, GaAs and TTL Logic
|
| |
| |
Tektronix
|
P6248
|
Tektronix P6248 Probe 1.5 Ghz Probe
|
$2,995.00
|
|
|
Tektronix P6248 Probe 1.5 Ghz Differential Probe Tektronix 1.5 Ghz P6248 Differential ProbeRent me for $200 a month
The Tektronix P6248 enable users to make time domain or frequency domain measurements on high-bandwidth signals commonly found in disk drive, digital IC design (RAMBUS) and communication applications (Gigabit Ethernet, IEEE-1394 Firewire and Fibre Channel). The P6248 includes accessories that allow RAMBUS via probing and IEEE-1394 interconnect access. The small probe head geometry and assorted probe tip accessories allow these probes to easily accommodate manual probing of surface mount devices while maintaining high CMRR. The P6248 are ideal for design verification of disk drive read, channel electronics and timing analysis for troubleshooting ground bounce problems associated with high-speed logic. They can also be used for pulse shape or cross talk compliance testing of high speed communication signals.
Features
- 1.7 GHz (Typical Probe Only <27°C) 1X Mode
- 1.5 GHz Bandwidth (Guaranteed)
- 1.85 GHz (Typical Probe Only <27°C) 10X Mode
- For use with Spectrum, Network Analyzers
- Square Pin Receptacle (Female)
- Electrostatic Discharge Tolerant
- Connects to TEKPROBE
- >60db(1000:) CMRR
Characteristics Bandwidth (guaranteed) P6248: DC to 1.5 GHz. P6247: DC to 1.0 GHz. P6246: DC to 400 MHz. Rise Time (specified) ¿ <265 ps (P6248), <350 ps (P6247), <875 ps (P6246). DC Attenuation Accuracy ¿ ±2%. Common Input Voltage Range ¿ ±7.0 V, 1X; ±7.0 V, 10X. Differential Input Voltage Range ¿ ±850 mV, 1X; ±8.5 V, 10X. Max. Nondestruct Input Voltage ¿ ±25 V (DC + peak AC). Electrostatic Immunity ¿ >15 kV.
TEKPROBE® Interface ¿ Probe power, autoscaling, auto-termination with TDS oscilloscopes.
Typical Specifications Input C Input R
|
| |
| |
Tektronix
|
P6249
|
Tektronix P6249 4 GHz Active Probe
|
$1,750.00
|
|
|
Tektronix P6249 4 GHz Active Probe
Tektronix P6249
4 GHz Active Probe
Rent me for $100 a month
Selecting the right probe for your application is key to
attaining the best signal fidelity in your measurements. Active probes provide
truer signal reproduction and fidelity for high frequency measurements.
Tektronix provides you a wide range of 4 GHz active probes to select from for
your application. The P6249 and P6241 have similar performances to the P7240.
Primarily used for the TDS694C and TDS794D performance scopes, the P6249 probes
may also be used with conventional BNC interfaces via the Tektronix 1103 TekProbe
Power Supply. The P6249 provides 4 Vp-p
dynamic range. A full complement of versatile probe tip accessories helps users
connect to the wide range of devices faced by digital designers. For use w/TEKPROBE
II interface.
Applications
- High-speed Digital Systems Design
- Component Design/Characterization
- Signal Integrity, Jitter and Timing Analysis
- Manufacturing Engineering and Test
- Signals with Voltage Swings up to 8 Vp-p
- Measures 3.0 V Logic, InfiniBand, PCI Express,
DDR, Rambus Data Lines, Gigabit Ethernet
Features
- <120 ps Rise Time (Guaranteed)
- 4 GHz Bandwidth
- <1 pF Input Capacitance
- Small Form Factor Probe Head
- +/-2V Dynamic Range
- Attenuation 5X
- Direct Access to SMDs
|
| |
| |
Tektronix
|
P6330
|
Tektronix P6330 3 Ghz Probe
|
$2,995.00
|
|
|
Tektronix P6330 3 Ghz Probe
Tektronix P6330 3 Ghz Probe Rent me for $200 a month
Features - 5 GHz to 3.5 GHz Bandwidths (Typical)
- Low Input Capacitance:
- 60 dB (1000:1) Common Mode Rejection Ratio (CMRR) at 1 MHz P6330 typical)
- Small Probe Head Allows Easy Probing of SMDs
Applications- Communications (Gigabit Ethernet, Fibre Channel, InfiniBand)
- Semiconductor Characterization & Validation (PCI-Express, Serial ATA, IEEE 1394, USB 2.0, RAMBUS, DDR)
- Disk Drive Design
Tektronix¡¯ proven expertise in probes brings you the highest fidelity in high-speed differential probing. The P6330 high BW differential probes offer excellent signal fidelity, meeting the needs of engineers in design & debug of technologies with very fast clock speeds and edge rates. They provide high-bandwidth, low circuit loading, low noise differential probing solutions for high-speed circuit designers. The P6330 enable users to make time domain or frequency domain measurements on high bandwidth signals commonly found in digital IC designs, communication applications, and disk drive applications. The P7330 and P6330 provide high-bandwidth, low circuit loading, and low noise differential probing solutions. The small probe head geometry and assorted probe tip accessories allow these probes to easily accommodate manual probing of surface mount devices. | | P6330 |
|---|
| Rise Time | <140 ps (guaranteed) | | Bandwidth | 3.5 GHz | | Attenuation | 5X | | Differential Input C | | Differential Input Resistance | 100 k¦¸ | | Differential Input Range | ¡À2 V (20 ¡ãC to 30 ¡ãC) | | Common Mode Input Range | +5 V to ¨C4 V | | Max Voltage (non-destruct) | ¡À25 V (DC plus peak AC) | | CMRR | >60 dB at 1 MHz (typical) | | Noise | Approx. 35 nV/root Hz | | Interface | TEKPROBE II BNC | | Cable Length | 1.3 m |
|
| |
| |
Tektronix
|
P6339A
|
Tektronix P6339A 500 Mhz Buffered Passive Probe
|
Contact Sales
|
|
|
Tektronix P6339A 500 Mhz Buffered Passive Probe Tektronix P6339A 500 Mhz Buffered Passive Probe Rent me for $200 a month
Features - 300 VRMS CAT II Maximum Input Voltage
- 8 pF Input Capacitance
- 10 MΩ Input Resistance
- Scope Controlled Parameters
- Connects to TEKPROBE¿ III Interface Instruments
- Compact Probe Tip Compatible with a Wide Range of Tektronix Accessories and Adapters
- TEKPROBE III Interface Allows Control of Key Probe Parameters
- Input Gain
- AC/DC Coupling
- Bandwidth Limiting
- DC Offset
Applications- General Purpose
- Digital Design
- Power Device Characterization
- Mixed Signal
Designed for TEKPROBE III, TDS794D and TDS694CThe P6339A 500 MHz Buffered Passive Probe is a revolutionary leap in probe technology. The P6339A's wide dynamic range makes it ideal for general purpose measurement applications. To facilitate SMD probing, the P6339A comes standard with a set of SureFoot® adapters. The compact probe head/tip assembly is compatible with the full line of 3.5 mm (compact) accessories. The P6339A probe is designed exclusively for the TDS794D and TDS694C instruments. - Maximum Input Voltage - 300 VRMS CAT II.
- Voltage Sensitivity - 10 mV/div to 100 V/div in a 1, 2, 5 sequence.
- DC Attenuation Accuracy - ±4%.
- Output Offset - ≤±5 mV.
Typical Specifications- Bandwidth - DC to 500 MHz.
- Rise Time - 700 ps.
- Input C - 8 pF.
- Input R - 10 MΩ.
Environmental Characteristics- Temperature - Operating: +10 °C to +40 °C (+50 °F to +104 °F).
- Safety - UL3111-2-031, CSAS1010.2.031, EN61010-2-031, IEC61010-2-031.
Compatible InstrumentsTDS794D, TDS694C.
|
| |
| |
Tektronix
|
P6407
|
Tektronix P6407 Word Recognizer Probe
|
Contact Sales
|
|
|
Tektronix P6407 Word Recognizer Probe
Tektronix P6407 Word Recognizer Probe
The Tektronix P6407 Word Recognizer Probe is a 16-bit probe for use with analog
and digital storage oscilloscopes. It allows the oscilloscope to trigger on
user-defined logic states (rather than on analog levels), thus extending the
utility of the oscilloscope into digital troubleshooting and debug applications.
Specifications
-
-0.5V to 5.5V Peak Max
-
20µA MAX at 2.7V
-
0.6mA MAX at 0.5V17-bit, TTL Compatible
- Up to 10MHz without External Clock
- 20MHz With External Clock
- For A or B Triggers
- Option 09 for 24XX Series Oscilloscope
|
| |
| |
Tektronix
|
P6418
|
Tektronix P6418
|
$300.00
|
|
|
Tektronix P6418
General-Purpose Probe and Accessories
The P6418 is a 17 channel general-purpose probe with leadsets
and grabber tips for use with: probing individual test points within
your target system, either directly or with a test clip, or direct
connection to legacy TLA family processor/bus support probe adapters
with 8 channel probe connectors. The P6418 works with a wide-range of
industry-standard probing accessories for flexible attachment to your
target system. This probe is recommended for most general-purpose
applications. Probe Cable Length - 1.9 m (6.25 ft.).
|
| |
| |
Tektronix
|
|
Tektronix P6487
|
Contact Sales
|
|
|
Tektronix P6487
Description:
High Speed Data Acquisition Probe. 10 Data Channels Plus 4 Clock Channels and 4 Qualifier Channels For PRISM 3000, 30MPX, 3001MPX
|
| |
| |
Tektronix
|
P6701B
|
Tektronix P6701B Optical/Electrical Probe
|
Contact Sales
|
|
|
New Page 1
Tektronix P6701B Optical/Electrical Probe
Features
- Broad Wavelength Response 500 to 950 nm or 1100 to 1700 nm
- High Bandwidth DC up to 1.2 GHz
- High Gain 1 V/mW
- Low Noise <11 pW/squareroot Hz
- Probe Connects Directly to TDS7000/5000/3000/500/600/700 Series Scope (TEKPROBE¿)
or Other 50 Ω Instruments with 1103 TEKPROBE® Power Supply
- SONET/SDH and Fibre Channel Reference Receiver Performance: TDS500C/700C
(Opt. 3C or 4C) P6701B: Fibre Channel up to 1063 Mb/s, P6703B:
SONET/SDH up to 622 Mb/s
Applications
- Eye-pattern Testing of Optical Communication Signals (SONET/SDH and Fibre
Channel)
The Tektronix P6700 Series optical-to-electrical (O/E) converters change
optical signals into electrical signals for convenient analysis on Tektronix
TDS7000/5000/3000/500/600/700 Series oscilloscopes equipped with the TEKPROBE
interface, or any other oscilloscope when used with the 1103 TEKPROBE power
supply. The P6700 Series O/E converters are ideal for optical source
characterization in the development, manufacture or service of optical
communication systems and devices.
Small, conveniently packaged P6701B and P6703B optical-to-electrical analog
converters provide an accurate interface for optical pulse shape measurements.
The high gain, large dynamic range and stable output offset of these O/E
converters make them ideal for performing eye-pattern analysis and extinction
measurements.
The P6701B/P6703B optical input is a one meter, 62.5μ multimode fiber
with an FC/PC connector. Using the standard assortment of hybrid fiber optic
mating sleeves, these O/Es can accommodate the various industry connector
standards.
The TEKPROBE interface provides power, auto-scaling, auto-termination and
correct units (microwatts) when used with Tektronix TDS500/600/700 Series
oscilloscopes.
SONET/SDH and Fibre Channel Reference Receiver Performance
The P6701B and P6703B can be transformed into ITU G.957 or ANSI FC-PH
reference receivers when they are either ordered as an option (3C - P6701B,
4C - P6703B) to the latest Tektronix TDS500C/700 Series digitizing
oscilloscopes or as a stand-alone hardware solution (nominal).
|
| |
| |
Tektronix
|
P7260
|
Tektronix P7260 6 GHz Active Probe
|
$3,500.00
|
|
|
Tektronix P7260 6 GHz Active Probe
Tektronix P7260 6 GHz Active Probe
Rent me for $500 a month
The Tektronix P7260 is the fastest active probe in the world. It
provides high-bandwidth, low circuit loading, low noise and accurate probing
solutions for high-speed circuit designers. This probe has a small probe head
for accessing connection points in tight physical constraints and with today's
fine pitch circuitry. The Tektronix P7260 is the world's first probe to be
developed with silicon germanium (SiGe). It features a toggle/switch that offers
the choice of using the probe at either 1.5 Vp-p or 6 Vp-p
dynamic range.
The TekConnect® interface takes probe intelligence to the next
level, providing probe power, automated signaling of scale factor and offset
voltage. It also adds automatic bandwidth adjustment and voltage measurement.
The TekConnect interface extends useful bandwidth and signal fidelity out to
18 GHz. A full complement of versatile probe tip accessories helps connect to
the wide range of devices faced by digital designers.
Features
- 6 GHz Bandwidth
- Switchable Attenuation Provides up to 6 Vp-p Dynamic Range
- Low Input Capacitance <0.5 pF
- Provides 6 GHz System Bandwidth at Probe Tip with TDS6604B TekConnect®
Oscilloscope
- Connect and Adapt to Various Circuit Designs with Small Probe Head and
Numerous Connection Accessories
- TekConnect Interface
Applications
- High-speed Digital Systems Design
- Component Design/Characterization
- Manufacturing Engineering and Test
| Attribute |
Specification 5x |
Specification 25x |
| Bandwidth (probe only, typical) |
6 GHz |
6 GHz |
| Rise time (guaranteed) |
<75 ps |
<85 ps |
| Input capacitance (pF) |
<0.5 pF |
<0.5 pF |
| Attenuation |
5x |
25x |
| Dynamic range |
±0.75 V (1.5 Vp-p) |
±3.0 V (6.0 Vp-p) |
| DC offset range |
±5 V |
±5 V |
| Input resistance |
20 kΩ at DC |
20 kΩ at DC |
| Maximum nondestruct voltage |
30 V (DC plus peak AC) |
| Compatible oscilloscopes*1 |
TDS6604B, TDS7404B, all TekConnect oscilloscopes |
*1 Requires firmware version 2.1 or higher for TDS/CSA7000 Series.
|
| |
| |
Tektronix
|
P7330
|
Tektronix P7330 High Performance Differential Probe
|
Contact Sales
|
|
|
Tektronix P7330 High Performance Differential Probe
Tektronix P7330 High Performance Differential
Probe
Rent me for $300 a month
For the
CSA/TDS8200, CSA/TDS8000,
TDS/CSA7000/B, and TDS6000/B/C mainframes
Tektronix¿ proven expertise in probes brings you the highest fidelity in
high-speed differential probing. The P7330 differential probes offer excellent
signal fidelity, meeting the needs of engineers in design & debug of
technologies with very fast clock speeds and edge rates. They provide
high-bandwidth, low circuit loading, low noise differential probing solutions
for high-speed circuit designers. The P7330 enable users to make time domain or frequency domain
measurements on high bandwidth signals commonly found in digital IC designs,
communication applications, and disk drive applications. The P7330 and P6330
provide high-bandwidth, low circuit loading, and low noise differential probing
solutions. The small probe head geometry and assorted probe tip accessories
allow these probes to easily accommodate manual probing of surface mount
devices.
Features
- <100 ps Risetime (P7350 Guaranteed)
- 5 GHz to 3.5 GHz Bandwidths (Typical)
- Low Input Capacitance:
- <0.3 pF Differential (P7350 Typical)
- ≥60 dB (1000:1) Common Mode Rejection Ratio (CMRR) at 1 MHz (P7330,
P6330 typical)
- Small Probe Head Allows Easy Probing of SMDs
Applications
- Communications (Gigabit Ethernet, Fibre Channel, InfiniBand)
- Semiconductor Characterization & Validation (PCI-Express, Serial ATA,
IEEE 1394, USB 2.0, RAMBUS, DDR)
- Disk Drive Design
|
| |
| |
Tektronix
|
P7380
|
Tektronix P7380 8 GHz Differential Probe
|
Contact Sales
|
|
|
Tektronix P7380
8 GHz Differential Probe
Tektronix
P7380
8 GHz Differential Probe
Rent me for $300 a month
Tektronix' active probe architecture preserves high bandwidth
while providing improved connectivity with low loading. The Z-Active
architecture is a hybrid approach composed of a distributed attenuator topology
feeding an active probe amplifier. With Z-Active architecture, the P7380
uses a
passive probe tip element that is separate from the amplifier, extending the
usable reach of the probe. The P7380
architecture maintains high DC input
resistance and a higher AC impedance than previous probe architectures while
providing significant length between the probe body and the probe attachment
point to the DUT. This architecture provides the best of both worlds, high DC
impedance along with the stable high frequency loading of Z0 probes.
The Tektronix P7380 differential probes can help you probe in
tight places while preserving high bandwidth and improving connectivity with low
loading. Key features include:
- Bandwidth>8.0 GHz (typical) P7380
- Rise time 10--90%<55 ps (guaranteed) P7380
- Interchangeable probe Tip-Clip Assemblies
- Solder down capability
- Variable space compliant handheld adapter
- Fixturing with an adapter
- Small probe head for easy probing of SMDs
- TekConnect Interface
Input resistance
- 100 KÙ differential
- 50 KÙ per side
Signal Fidelity
You can be confident in the signal fidelity of your
measurements because the Z-Active¿ architecture provides:
-
High bandwidth
-
Excellent step response
-
Low loading
-
High CMRR
Connectivity
This family of probes uses Tip-Clip¿ assemblies, an
interchangeable probe tip system that enables customers to configure their probe
with the optimal tip for their application. These detachable assemblies make it
possible to replace a tip for a fraction of the cost formerly associated with
such hardware changes. The several lengths and variable spacing of the
assemblies provide flexibility for adapting to other test points of differing
sizes. With Tektronix Tip-Clip assemblies, Monday¿s solder-in probe can become
Tuesday¿s handheld tool, simply by switching tips. The Z-Active probe design
allows the probe to easily switch between solder, handheld or fixtured
applications.
|
| |
| |
Tektronix
|
TAP3500
|
Tektronix TAP3500 3.5 GHz Active Probe
|
Contact Sales
|
|
|
Tektronix TAP3500 3.5 GHz Active Probe
Tektronix TAP3500 3.5 GHz Active Probe
Rent me for $300 a month
For the Tektronix TekVPI probe
interface used on the DPO7000 and DPO4000 Series oscilloscopes
Selecting the right probe for your application is
key to attaining the best signal fidelity in your measurements. Active probes
provide truer signal reproduction and fidelity for high frequency measurements.
With our ultra-low input capacitance and unique interface, the TAP2500 and
TAP3500 Single-ended Active FET probes provide excellent high-speed electrical
and mechanical performance required for today¿s digital system designs.
Specifically designed for use and direct connection to the TekVPI probe interface used on the DPO7000 and DPO4000 Series oscilloscopes, the TAP2500 and TAP3500 Active FET probes achieve high-speed signal acquisition and measurement fidelity by solving three traditional problems:
- Lower DUT loading effects with ≤0.8 pF
input capacitance and 40 kΩ input resistance
- Versatile DUT connectivity for attaching to small SMDs
- Preserves oscilloscope bandwidth at the probe tip for DPO7000 and DPO4000 Series Oscilloscope models up to 3.5 GHz
Features
Outstanding Electrical Performance
- High Probe Bandwidth
- Fast Probe Rise Time
- Excellent Signal Fidelity
- 0.8
pF Input Capacitance
- 40 kohm Input Resistance
- -4 V to +4 V Input Dynamic
- -10 V to +10 V DC Input Offset
- ±30 V (DC + pkAC) Max Input Voltage (Non-Destruct)Small Compact Probe Head for Probing Small Geometry
Circuit Elements
- DUT Attachment Accessories Enable Connection to SMDs as Small as 0.5 mm Pitch
- Robust Design for Reliability
Easy to Use
- Connects Directly to DPO7000 and DPO4000 Series Oscilloscopes Using the New TekVPI Probe Interface
- Provides Automatic Units Scaling and Readout on the Oscilloscopes Display
- Easy Access to Oscilloscope Probe Menu Display for Probe Status/Diagnostic Information and to Control Probe DC Offset
Applications
- Verification, Debug and Characterization of High-speed Designs
- Signal Integrity, Jitter and Timing Analysis
- Manufacturing Engineering and Test
- Signals with Voltage Swings Up to 8 Vpk-pk
|
| |
| |
Tektronix
|
TCA-SMA
|
Tektronix TCA-SMA Tekconnect SMA Adapter
|
Contact Sales
|
|
|
Tektronix TCA-SMA Tekconnect SMA Adapter
Tektronix
TCA-SMA Tekconnect SMA Adapter
Available for rentals please call
TCA-SMA Adapters (50 Ω only)
The high-speed SMA adapters allow a more direct connection to
the signal under test requiring SMA connections without losing performance by
adding other external conversion adapters. Bandwidth is rated to 18 GHz.
TekConnect Interface Delivers Superior Signal Fidelity,
Unparalleled Versatility and Ease-of-use
The TekConnect interface ensures superior signal
fidelity with useful bandpass up to 18 GHz at the oscilloscope input, while
offering unparalleled versatility with the world’s widest array of accessory
signal acquisition solutions for high-performance, real-time oscilloscopes. This
interface delivers a more robust oscilloscope interface for next-generation
products with multi-GHz analog bandwidths, overcoming many of the inherent
bandwidth limitations of BNC-based interfaces. The TekConnect interface
preserves a low voltage standing wave ratio (VSWR) 50 Ω
environment as well as a reliable electrical connection. A convenient,
one-button release and locking mechanism provides quick, easy installation and
removal of probes, amplifiers and adapters.
|
| |
| |
Tektronix
|
TCP202
|
Tektronix TCP202 Current Probe
|
$1,450.00
|
|
|
Tektronix TCP202 Current Probe
Tektronix TCP202 Current Probe
Rent me for $150 a month
Features
- Easy Current Measurements
- Probe Connects Directly to TDS Scope through TEKPROBE¿ BNC
Interface
- Split Core Construction for Easy Circuit Connection
- DC to 50 MHz Bandwidth
- 15 Amps DC + Peak AC Current
- 50 Amps Peak Pulse Current
- 500 x 10-6 Ampere-Sec Product
- Safety Certified
Applications
- Motor Drives
- Switching Power Supplies
- Disk Drive
- Electronic Ballasts
- Inverters
- Avionics
TCP202 DC Coupled Current Probe
When combined with a Tektronix TDS oscilloscope, the TCP202 enables users to
make direct readout DC and AC current measurements, resulting in accurately
displayed and recorded measurements.
The TCP202 is a general-purpose probe for displaying and measuring current in
electronic circuits. It is ideal for power supply and motor drive design, and
for device testing.
Characteristics
- Bandwidth - DC to 50 MHz.
- Max DC + Peak AC Current - 15 A.
- Max Peak Pulse Current - 50 A.
- Minimum Sensitivity - 10 mA/div.
- DC Accuracy -
- ±1% (with probe calibrator).
- ±3% (without probe calibrator).
- Max Bare Wire Voltage - 300 V (CAT I).
Typical Characteristics
- Insertion Impedance -0.002 Ù at 1 kHz. 0.1 Ù at 5 MHz.
- Propagation Delay - 17 ns.
- Max Conductor Diameter - 3.8 mm (0.15 in.).
Recommended Oscilloscopes
TDS520B; TDS520C; TDS520D; TDS540B; TDS540C; TDS540D; TDS580C; TDS580D;
TDS654C, TDS680C, TDS684C, TDS694C, TDS724A; TDS724C; TDS724D; TDS744A
(S/N B040100 or higher); TDS754A; TDS754C; TDS754D; TDS784A (S/N B040100 or
higher); TDS784C; TDS784D; TDS794D; TDS3000 Series; TDS3000B Series, TDS5000
Series; TDS5000B Series; TDS6000 Series and TDS6000B Series with TCA-BNC
adapter; TDS7000 Series and TDS7000B Series with TCA-BNC adapter.
|
| |
| |
Tektronix
|
YT5100
|
Tektronix YT5100 X10 100 MHz Passive Oscilloscope Probe
|
Contact Sales
|
|
|
Tektronix YT5100 X10 100 MHz Passive Oscilloscope Probe
Tektronix YT5100 X10 100 MHz Passive
Oscilloscope Probe
The Tektronix YT5100
Switchable X1/X10 Oscilloscope probe that offers Tektronix legendary reliability
with a mass market price. Works with any oscilloscope that has a bandwidth of
100 MHz or less.
|
| |
|
Test Equipment, test eqipment, test and measurement, US INSTRUMENT SERVICES, rental, sales, used, HP, Hewlett Packard, Tektronix, tektronics, TEK, CSI, Campbell, oscilloscopes, ossiliscopes, optical, fiberoptic, Telecom, test sets, network, logic, B&K, Bruel, Kjaer, Dranetz, Telecom, TTC, Wandel, Goltermann, spectrum analyzers, logic analyzers, digital, multimeters, counters, data acquisition, HiPot, meggers, ground testing, protocol, pirateracing, butch
|
©1999-2002 [fill in company name] All Rights Reserved |
contact
webmaster
| powered by
corezon
|
|
All logos and trademarks are properties of their respective companies. Product price,
specification, warranty and availability subject to change without notice.
|
|
|