HTML Content Started Here
************************************************************
--%>
Category : Data Loggers

|
|
Mfg. Name |
Mfg. Part# |
Product |
Unit Price |
Add To Cart |
| |
| |
AEMC
|
SDL-402
|
AEMC Sentinel SDL-402 AC/DC Current Datalogger
|
Contact Sales
|
|
|
AEMC Sentinel SDL-402 AC/DC Current Datalogger
AEMC Sentinel SDL-402 AC/DC Current Datalogger
Rent me for $300 a month
The Sentinel Current Logger Model SDL A402 is a four-channel
current logger recording device designed for use with AEMC detachable current
probes . The Model SDL A402 is powered with rechargeable NiMH batteries.
Real-time display of waveforms and harmonics is available with the DataView
software, which is included. Programmable storage rate and storage modes,
combined with simple one button operation, make this a versatile and easy-to-use
data logger, perfect for a variety of applications.
Features
True RMS current measurements
DC current measurements when used with Hall Effect Current Probes on
Model SDL A402
Low-cost, self-contained, portable
Measures up to 1000A (probe dependent)
Programmable storage mode
Programmable storage rate
Records up to 480,000 measurements (1MB)
64 samples per cycle
Includes DataView® software
Optically isolated USB 2.0 communication
Detachable current probes
600V Cat. III, 300V Cat. IV
Applications
Load profiling
Energy management
Preventative maintenance
Stray current monitoring
|
| |
| |
Agilent / HP
|
34901A
|
Agilent/HP 34901A 20 Channel Input Module
|
$425.00
|
|
|
Agilent/HP 34901A 20 Channel Input Module for 34970A Series Dataloggers
Agilent/HP 34901A 20 Channel Input
Module for 34970A Series Dataloggers
Rent me for $50 a month
The Agilent/HP 34901A module for the 34970A Data Acquisition/Switch
Unit is the most versatile multiplexer for general purpose scanning. It combines
dense, multi-function switching with 60 channel/second scan rates to address a
broad spectrum of data acquisition applications. Two and four-wire channels can
be mixed on the same module. Two additional fused inputs (22 channels total)
route up to 1A of current to the internal DMM, allowing ac and dc current
measurements without the need for external shunt resistors. The Agilent/HP
34901A is an excellent general
purpose module. Agilent has very long delivery dates. We have it in stock today!
20-Channel General-Purpose Multiplexer
Up to three modules, in any combination, can be inserted into a
single mainframe. The 34970A's internal DMM connections are accessible only
through the 34901A, 34902A, and 34908A low frequency multiplexers. On-module
screw terminals accept wire sizes from 16 gage to 22 gage. Twenty-gage wire is
recommended for high channel count applications. The 34905A and 34906A RF
Multiplexers use SMB connectors. A standard set of (10) BNC-to-SMB adapter
cables is provided with each RF module for convenient BNC connections. Two- and
four-wire channels can be mixed on the same module. Two additional fused inputs
(22 channels total) route up to 1A of current to the internal DMM, allowing ac
and dc current measurements without the need for external shunt resistors.
Each of the 20 channels switches both HI and LO inputs, thus
providing fully isolated inputs to the internal multimeter. The module is
divided into two banks of 10 two-wire channels each. When making four-wire
resistance measurements, channels from Bank A are automatically paired with
channels from Bank B. Two additional fused channels are included on the module
(22 channels total) for making calibrated DC or AC current measurements with the
internal multimeter (external shunt resistors are not required). You can close
multiple channels on this module only if you have not configured any channels to
be part of the scan list. Otherwise, all channels on the module are
break-before-make.
|
| |
| |
Agilent / HP
|
34903A
|
Agilent/HP 34903A 20 Channel Input Module
|
$299.00
|
|
|
Agilent/HP 34903A 20 Channel Actuator/ Switch Module
Agilent/HP 34903A 20 Channel
Actuator/ Switch Module
Rent me for $50 a
month
The Agilent/HP 34903A is a general-purpose switch module for the
34970A Data Acquisition/Switch Unit. It has 20 independent single-pole,
double-throw (SPDT) relays and is used to cycle power to products under test,
control indicator and status lights, and to actuate external power relays and
solenoids. Combine it with matrix and multiplexer modules to build custom switch
systems. Its 300 V, 1 A contacts can handle up to 50 W, enough for many power
line switching applications.
Features
- 20 Channel Actuator/GP Switch
- SPDT (Form C) latching relays
- 300 V, 1 A actuation and control
Use this module for those applications that require
high-integrity contacts or quality connections of non-multiplexed signals. This
module can switch 300 V, 1 A (50 W maximum switch power) to your device under
test or to actuate external devices. Screw terminals on the module provide
access to the Normally-Open, Normally-Closed, and Common contacts for each of
the 20 switches. A breadboard area is provided near the screw terminals to
implement custom circuitry, such as simple filters, snubbers, or voltage
dividers.
|
| |
| |
Agilent / HP
|
44473A
|
Agilent/HP 44473A 4x4 Two-Wire Matrix Switch
|
Contact Sales
|
|
|
Agilent/HP 44473A 4x4 Two-Wire Matrix Switch
Agilent/HP 44473A 4x4 Two-Wire Matrix
Switch
Rent me for $100 a month
For the 3488A Switch/Control Unit
The 44473A offers highly flexible switching with a 4 X 4, 2-wire
matrix. Any combination of 4 input channels may be connected to any
combination of 4 output channels. Each cross point or node in the matrix
uses a 2SPST relay to switch 2 lines (Hi and Lo) at a time. Multiple 4 X 4
modules can be connected to form larger matrices. Multiplexers can be used
in conjunction with this larger module to effectively expand the number of
inputs and outputs of the matrix.
Input Characteristics
8
Maximum Voltage: 250V
Maximum Current:
Per channel: 2A, Per module: 8A
Maximum Power:
Per channel: 60W; 125VA, Per module: 240W;500VA
Initial Closed Channel Resistance: <1 Ohm
DC Isolation (<40°C, <60%RH)
AC Isolation
|
| |
| |
Agilent / HP
|
3488A
|
Agilent/HP 3488A Switch/Control Unit
|
$100.00
|
|
|
Agilent/HP 3488A Switch/Control Unit
Agilent/HP 3488A Switch/Control Unit
Requires additional modules for operation
The Agilent/HP 3488A Switch/Control Unit brings versatile, HP-IB
programmable switching to tests requiring multi-channel measurements. The
Agilent/HP 3488A provides single switching with the integrity and isolation
needed for high-performance production test systems. It also offers a
flexible, low-cost interconnection for automating experiments on the bench and
for developing tests in the lab. The Agilent/HPHP 3488A is designed to
hold up to 5 of the switch and control modules.
Features
- DC-26.5 signal switching
- Matrix, multiplexer, and general purpose relays
- Digital I/O control and actuation
- Up to 50 channels
- 40 configuration storage registers
- 11 switch and control modules
Flexible Switching
The Agilent/HP 3488A is an economical approach to flexible
switching through plug-in modules. You can select the right combination of
switching functions to meet both performance and budget needs. Testing is
simplified by having one solution for connections of low-level DVM inputs,
high-level dc and ac power, and microwave signals to 26.5 GHz. Additional
devices, such as microwave relays and programmable attenuators, are easily
controlled with digital I/O functions. Custom circuitry can also be
implemented on breadboard modules.
Versatile Performance
The Agilent/HP 3488A can store up to 40 complete switch
configurations for convenient recall in automated test programs. Switch
operation can be done with multiple relay closures or with selectable channels
in a break-before-make mode. Break-before-make and recallable switch
configurations can be combined in a programmable scan list. The Agilent/HP
3488A uses removable screw connectors that provide easily interchangeable wiring
for each test. Built-in self-test assures proper operation.
|
| |
| |
Agilent / HP
|
34902A
|
Agilent/HP 34902A 16 Channel Multiplexer
|
$449.00
|
|
|
Agilent/HP 34902A 16 Channel Multiplexer
(2/4-wire) Module for 34970A
Agilent/HP 34902A 16 Channel Multiplexer
(2/4-wire) Module for 34970A
Rent me for $50 a month
The Agilent 34902A module for the 34970A Data Acquisition/Switch
Unit employs reed relays to achieve scan rates up to 250 channels-per-second.
Use this module for high-throughput automated test applications as well as
high-speed data logging and monitoring tasks. Sixteen two-wire inputs switch up to 300 V. Two-and four-wire
channels may be mixed on the same module. User provided shunt resistors are
required for current measurements.
Features
- 16 Channel Multiplexer
- 250 Channels per second scanning rate
- Two- and four-wire scanning
- Built-in thermocouple reference junction
Use this module for high-speed scanning and high-throughput
automated test applications. Each of the 16 channels switches both HI and LO
inputs, thus providing fully isolated inputs to the internal multimeter. The
module is divided into two banks of eight two-wire channels each. When making
four-wire resistance measurements, channels from Bank A are automatically paired
with channels from Bank B. You can close multiple channels on this module only
if you have not configured any channels to be part of the scan list. Otherwise,
all channels on the module are break-before-make.
Multiplexer Selection Guide
Choose between the broad functionality of the 34901A, the high
speed scanning of the 34902A, or the single-ended density of the 34908A. These
three modules are the only way to connect to the 34970A internal DMM. They can
be used to scan with external instruments as well. All multiplexer modules
employ break-beforemake scanning, ensuring only one closed channel (or channel
pair) at a time. Multiple channel closures are allowed on the 34901A and 34902A
modules when not configured for scanning. The 34908A does not allow multiple
channel closures at any time.
Up to three modules, in any combination, can be inserted into a
single mainframe. The 34970A's internal DMM connections are accessible only
through the 34901A, 34902A, and 34908A low frequency multiplexers. On-module
screw terminals accept wire sizes from 16 gage to 22 gage. Twenty-gage wire is
recommended for high channel count applications. The 34905A and 34906A RF
Multiplexers use SMB connectors. A standard set of (10) BNC-to-SMB adapter
cables is provided with each RF module for convenient BNC connections.
|
| |
| |
Agilent / HP
|
34904A
|
Agilent/HP 34904A 4x8 Two-Wire Matrix Switch for the 34970A Datalogger
|
Contact Sales
|
|
|
Agilent/HP 34904A 4x8 Two-Wire Matrix Switch for the 34970A Datalogger
Agilent/HP 34904A 4x8 Two-Wire Matrix Switch
for the 34970A Datalogger
Rent me for $50 a month
The Agilent/HP 34904A for the 34970A Two-Wire Matrix Switch for
the Datalogging Mainframe gives you the most flexible connection path between
your device under test and your test equipment, allowing different instruments
to be connected to multiple points on your DUT at the same time. Rows or columns
may be connected between multiple modules to build 8x8, 4x16 or larger matrices,
with up to 96 crosspoints in a single frame.
Features
Use this module to connect multiple instruments to multiple
points on your device under test at the same time. You can connect rows and
columns between multiple modules to build larger matrices such as 8x8 and 4x16,
with up to 96 crosspoints in a single mainframe.
|
| |
| |
Agilent / HP
|
34905A
|
Agilent/HP 34905A 2 GHz Dual 1:4 RF 50 Ohm Module for the 34970A Datalogger
|
Contact Sales
|
|
|
Agilent/HP 34905A 2 GHz Dual 1:4 RF 50 Ohm Module for the 34970A
Datalogger
Agilent/HP 34905A 2 GHz Dual 1:4 RF 50 Ohm
Module for the 34970A Datalogger
Rent me for $50 a month
The Agilent/HP 34905A RF multiplexer module for the 34970A Data
Acquisition/Switch Unit offers broadband switching capabilities for
high-frequency and pulsed signals. Use it to route test signals between your
device under test and your signal generator, oscilloscope, spectrum analyzer, or
other instrumentation. The RF multiplexers are arranged as two independent 1 x 4
multiplexers, each with a common shield and a switched center conductor.
Connections can be made directly to SMB inputs with 2 GHz usable bandwidth, or
to the BNC-to-SMB adapters provided with 1 GHz bandwidth. Multiple banks may be
cascaded together for applications requiring even larger topologies-- create a
stubless 16:1 multiplexer in a single frame.
Features
- Dual 4 Channel RF Multiplexer
- 2 GHz bandwidth, 50 Ohm
- BNC to SMB adapter cables included
- 10 Cables, 50 Ohm (SMB to BNC)
These modules offer wideband switching capabilities for high
frequency and pulsed signals. Each module is organized in two independent banks
of 4-to-1 multiplexers. Both modules offer low crosstalk and excellent insertion
loss performance. To create larger RF multiplexers, you can cascade multiple
banks together. Only one channel in each bank may be closed at a time.
|
| |
| |
Agilent / HP
|
34907A
|
Agilent/HP 34907A Multifunction Module
|
$320.00
|
|
|
Agilent/HP 34907A Multifunction Module for the 34970A Datalogger
Agilent/HP 34907A
Multifunction Module for the 34970A Datalogger
Rent me for $50 a month
The Agilent/HP 34907A module for the 34970A Data
Acquisition/Switch Unit allows great flexibility for a variety of sense
and control applications. It combines two 8-bit ports of digital input
and output, a 100 kHz gated totalizer, and two ±12V analog
outputs - all on a single earth-referenced module. The digital inputs
and totalizer input may be included in a scan. Alarm limits for the
digital and event counter inputs are evaluated continuously, capturing
and logging alarm conditions even between scans.
Features
- 16 bits of digital input and output
- 100 kHz totalizer input
- Two ±12V analog outputs
Use this module to sense status and control external devices such as
solenoids, power relays, and microwave switches. For greater flexibility, you
can read digital inputs and the count on the totalizer during a scan. The Agilent 34907A module for the 34970A Data
Acquisition/Switch Unit allows great flexibility for a variety of sense
and control applications. It combines two 8-bit ports of digital input
and output, a 100 kHz gated totalizer, and two ±12V analog
outputs - all on a single earth-referenced module. The digital inputs
and totalizer input may be included in a scan. Alarm limits for the
digital and event counter inputs are evaluated continuously, capturing
and logging alarm conditions even between scans.
Digital Input/Ouput
Use the digital outputs with an external power supply
to control microwave switches and attenuators, solenoids, power relays,
indicators, and more. Use the digital inputs to sense limit switch and
digital bus status. There are no complex handshake modes; reads and
writes are initiated either from the front panel or the bus.
Totalize Input
Count events from devices like photo interrupters,
limit switches, and Hall-effect sensors. It keeps an updated total which can be read via the
front panel or programmatically at any time. With 26 bits of
resolution, it can count events at full speed for nearly 45 minutes
without an overflow.
Analog Output
Use the two electronically calibrated analog outputs to
source bias voltages to your device under test, to control your analog
programmable power supplies, or use the outputs as setpoints for your
control systems. The outputs are programmed directly in volts, either
from the front panel or from the bus.
|
| |
| |
Agilent / HP
|
34908A
|
Agilent/HP 34908A 40 Channel Single-Ended Multiplexer Module
|
Contact Sales
|
|
|
Agilent/HP 34908A 40 Channel Single-Ended Multiplexer Module
Agilent/HP 34908A 40 Channel Single-Ended
Multiplexer Module
Rent me for $50 a month
Use the Agilent 34908A module for the 34970A Data
Acquisition/Switch Unit for the greatest density in common-low applications,
such as battery test, component characterization, and bench top testing. Each
module switches 40 one-wire inputs. All two-wire internal measurements except
current are supported. The module low connection is isolated from earth and can
float up to 300 V.
Features
- 40 Channel Single-Ended Multiplexer
- 60 ch/s scanning
- Single-wire switching for common-low applications
- Built-in thermocouple reference junction
Use this module for high-density switching applications which
require single-wire inputs with a common LO. All relays are break-before-make to
ensure that only one relay is connected at any time.
Note: Thermocouples must be electrically isolated from each
other to avoid current loops and subsequent measurement errors.
|
| |
| |
Agilent / HP
|
34970A
|
Agilent/HP 34970A Datalogger Mainframe
|
$1,249.00
|
|
|
Agilent 34970A Datalogger Mainframe
Agilent/HP 34970A
Datalogger Mainframe
Rent me for $150 a month for base unit only
Requires additional plug in modules
for operation
The
best and easiest datalogger to use. No hassles or grief. Fast quick results.
Requires plug in modules for your application. The Agilent/HP 34970A consists of
a three-slot mainframe with a built-in 6 ½ digit DMM. Each channel can be
configured independently to measure one of 11 different functions without the
added cost or hassles of signal-conditioning accessories. Choose from eight
optional plug-in modules to create a compact data logger, full-featured data
acquisition system or low-cost switching unit. On-module screw-terminal
connections eliminate the need for terminal blocks and a unique relay
maintenance feature counts every closure on every switch for easy, predictable
relay maintenance. Our most popular module 34901A features a built-in
thermocouple reference and 20 two-wire channels.
Features
- 3-slot mainframe with built-in GPIB and RS232 interfaces
- 6 ½-digit (22-bit) internal DMM, scanning up to 250 channels per
second
- Built-in Signal conditioning measures thermocouples, RTDs, &
Thermistors, ac/dc Volts, & Current; Resistance; Frequency and Period
- 8 switch and control plug-in modules to choose from
- 50k readings of non-volatile memory holds data when power is removed
- Hi/LO alarm limits on each channel, plus 4 TTL alarm outputs
The Agilent/HP Technologies 34970A combines precision measurement capability
with flexible signal connections for your production and development test
systems. Three module slots are built into the rear of the instrument to accept
any combination of data acquisition or switching modules. The combination of
data logging and data acquisition features in the 34970A makes this instrument a
versatile solution for your testing requirements now and in the future.
Plug ins available include 34901A
20-CH multiplexer (2/4-wire) 60 300 V 1 A 2 current channels (22 ch total)
Built-in cold junction reference 34902A
16-CH multiplexer (2/4-wire) 250 300 V 50 mA Built-in cold junction reference
34903A 20-CH actuator/GP switch 120 300 V 1 A Form C (SPDT) switches
34904A 4x8 matrix 120 300 V 1 A 2-wire, full crosspoint
34905A 2-GHz dual 1:4 RF mux, 50 ohm 60 42 V 0.7 A 1-GHz through provided
BNC-to-SMB adapter cables 34906A 2-GHz
dual 1:4 RF mux, 75 ohm 60 42 V 0.7 A 1-GHz through provided BNC-to-SMB adapter
cables 34907A 2 8-bit digital I/O
ports; 26-bit, 100-kHz event counter; 2 16-bit analog outputs 42 V; 42 V; +/-12
V 400 mA; ; 10 mA Open drain; Gated, selectable input threshold; Earth
referenced. Calibrated. 34908A 40-CH
single-ended multiplexer 60 300 V 1 A Common low, no 4-wire meas. Built-in cold
junction reference
|
| |
| |
Agilent / HP
|
34980A
|
Agilent/HP 34980A Datalogger System
|
Contact Sales
|
|
|
Agilent/HP 34980A Datalogger System
Agilent/HP 34980A Datalogger System
Available for Rentals. Price varies with installed options
21 different input modules available. Up to 560 Channels available.
The Agilent/HP 34980A Multifunction Switch/Measure Unit is a compact,
economical, one-box solution for medium to high-density switch/measure
applications in design verification, automated test and data acquisition. The
Agilent/HP 34980A is an eight-slot mainframe that has an optional built-in 6.5
digit DMM with your choice of 21 different plug-in modules. These include
switching from DC to 20 GHz, digital I/O, D/A converters, and counter/totalizer
functionality. One mainframe can accommodate up to 560 2-wire multiplexer
channels or 1024 2-wire matrix cross points. The 34980A also includes USB,
Ethernet, and GPIB as standard interfaces to the PC. With Ethernet connections
and the graphical web interface, you can access and control the unit remotely.
Standard connectors on the modules also allow you to use standard, off-the-shelf
50- and 70-pin shielded cables to easily connect test signals from the
instrument to the unit under test or other test points. Additional wiring
options include detachable terminal blocks for discrete wiring needs and mass
interconnect solutions. The 34980A is a low-cost modular
platform that is easily expandable and reconfigurable. It offers broad
functionality that fits your budget without sacrificing accuracy.
Multiplexer modules
- 34921A 40-channel armature multiplexer w/low thermal offset
- 34923A 40/80-channel reed multiplexer
- 34925A 40/80-channel optically isolated FET multiplexer
- 34922A 70-channel armature multiplexer
- 34924A 70-channel reed multiplexer
Matrix modules
- 34931A Dual 4x8 armature matrix
- 34932A Dual 4x16 armature matrix
- 34933A Dual/quad 4x8 reed matrix
- 34934A Quad 4x32 reed matrix
General purpose/actuator modules
- 34937A 32-channel Form C/Form A general-purpose switch
- 34938A 20-channel 5-amp Form A switch
- 34939A 64-channel Form A Switch
RF and microwave modules
- 34941A Quad 1x4 50-ohm 3-GHz RF multiplexer
- 34942A Quad 1x4 75-ohm 1.5 GHz RF multiplexer
- 34945A Microwave switch/attenuator driver
- 34946A Dual 1x2 SPDT terminated microwave switch
- 34947A Triple 1x2 ww unterminated microwave switch
System measurement and control modules
- 34950A 64-bit digital I/O with memory and counter
- 34951A 4-channel isolated D/A converter with waveform
- 34952A Multifunction module with 32-bit DIO,
- 34959A Breadboard module 26- & 40-pin internal
|
| |
| |
Agilent / HP
|
34906A
|
Agilent/HP 39406A 75 Ohm RF Switch
|
$500.00
|
|
|
Agilent/HP 34906A 75 Ohm RF Switch for the 34970A Datalogger
Agilent/HP 34906A 75 Ohm RF
Switch for the 34970A Datalogger
Rent me for $50 a month
The Agilent 34906A RF multiplexer module for the 34970A Data
Acquisition/Switch Unit offers broadband switching capabilities for
high-frequency and pulsed signals. Use it to route test signals between
your device under test and your signal generator, oscilloscope,
spectrum analyzer, or other instrumentation. The RF multiplexers are
arranged as two independent 1 x 4 multiplexers, each with a common
shield and a switched center conductor. Connections can be made
directly to SMB inputs with 2 GHz usable bandwidth, or to the
BNC-to-SMB adapters provided with 1 bandwidth. Multiple banks may be
cascaded together for applications requiring even larger
topologies--create a stubless 16:1 multiplexer in a single frame.
Features Dual 4 Channel RF Multiplexer 2 GHz bandwidth, 75 Ohm BNC to
SMB adapter cables included
Features
These modules offer wideband switching capabilities
for high frequency and pulsed signals. Each module is organized in two
independent banks of 4-to-1 multiplexers. Both modules offer low crosstalk and
excellent insertion loss performance. To create larger RF multiplexers, you can
cascade multiple banks together. Only one channel in each bank may be closed at
a time.
|
| |
| |
Agilent / HP
|
44470A
|
Agilent/HP 44470A Multiplexer
|
$100.00
|
|
|
Agilent/HP 44470A Multiplexer
Agilent/HP 44470A Multiplexer
For the 3488A Switch/Control Unit
Option 010 is a 10-channel multiplexer for scanning or multiple signal
connections. Channels switch 2 wires (Hi and Lo) with 2 PST relays for DVM
inputs and other signals up to 250V and 2A. This module can also be used
to multiplex signals to other switching functions, such as the matrix module.
|
| |
| |
Agilent / HP
|
44471A
|
Agilent/HP 44471A General Purpose Relay
|
$100.00
|
|
|
Agilent/HP 44471A Switch/Control Unit
Agilent/HP 44471A General Purpose Relay
For the 3488A Switch/Control Unit
This module consists of 10 SPST independent relays for general signal
switching and control of external devices. Quality connections make this module
ideal for switching signals when multiplexing is not required, or for supplying
switchable power to the device under test.
|
| |
| |
Agilent / HP
|
44472A
|
Agilent/HP 44472A Dual 1x4 VHF Multiplexer
|
$199.00
|
|
|
Agilent/HP 44472A Dual 1x4 VHF Multiplexer
Agilent/HP 44472A Dual 1x4 VHF Multiplexer
For the Agilent/HP 3488A and 3499A
Mainframes
The Agilent/HP 44472A VHF module offers broadband switching
capability for high frequency and pulse signals. Two independent 50 Ohm
character impedance bi-directional 1x4 switches are provided for signals from DC
to 300 MHz. Very low crosstalk makes the VHF module ideal for VHF signal
measurements using spectrum, network, or distortion analyzers. You can also use
the excellent signal integrity of the VHF module for multiplexing inputs to your
GPIB oscilloscope or waveform analyzer. Each group of four channels is isolated
from the other and from the chassis to prevent ground loops. BNC connectors
provide ease of connection to the module.
Features
- DC to 300MHz
- BNC connectors for ease of wiring
- For 3488A & 3499A/B/C Mainframes
The 2 independent groups of bidirectional 1 X 4 switches can be
used for signals from dc to 300 MHz. All channels have 50-ohm
characteristic impedance and are break-before-make within a group of 4 channels.
Each group is isolated from the other and from ground to prevent ground loops.
Excellent isolation makes this module ideal for high-frequency signal analyzer
measurements requiring a large dynamic range.
|
| |
| |
Agilent / HP
|
44474A
|
Agilent/HP 44474A Digital I/O
|
$100.00
|
|
|
Agilent/HP 44474A Digital I/O
Agilent/HP 44474A Digital I/O
For the 3488A Switch/Control Unit
This module offers 16 very flexible bidirectional I/O lines and 4 TTL-compatible
handshake lines for sensing and control of external devices. The digital
inputs can be used to sense contact closures to ground. Each channel
provides current sinks for remote switching of external relays, such as the HP
33311 series coaxial switches.
|
| |
| |
Cambell Scientific
|
CR21
|
Campbell Scientific CR21 Micrologger
|
Contact Sales
|
|
|
Campbell Scientific CR21 Micrologger
Campbell Scientific CR21 Micrologger The CR21 featured an integrated design with built-in power supply,
keyboard, and display. It looks very similar to, and is often confused with its
replacement, the 21X Micrologger. The CR21 stored up to 608 data points in
internal memory. A typical field-based CR21 consists of a CR21 or CR21L
Micrologger with a CR21 Instruction Set (PROMs).
Features
- Replaced by the 21X Micrologger® (now retired), CR23X Micrologger®
- Manufactured from 1979-1985
- Self-contained datalogger with built-in keyboard and power supply
- Specialized sensors required; some no longer available
- Stored 608 data points in internal memory (volatile)
- ASCII data format
- Some repairs no longer available
Specifications
- Seven single-ended analog inputs (-0.2 to +2.5 Vdc or
-2 mV to +25 mV, FSR)
- Two pulse count channels (150 Hz (CH 8) and 50 Hz (CH 9), maximum
input frequency)
- One 4 Vac excitation channel
- Three 2 Vdc sensor excitation channels
- Two binary inputs
- Four control outputs
- One 5 Vdc power terminal
- One 12 Vdc power terminal
- One a serial I/O port.
|
| |
| |
Cambell Scientific
|
SM64
|
Campbell Scientific SM64 Storage Module
|
Contact Sales
|
|
|
Campbell Scientific SM64 Storage Module
Campbell Scientific SM64 Storage Module The Campbell Scientific SM64 Storage module is an external memory
module. Designed to work with the CR21 Datalogger.
|
| |
| |
Fluke
|
642496
|
Fluke 2280A 162 20 Channel Input Card
|
$100.00
|
|
|
Fluke 2280A 2280A/62 20 Channel Isothermal Input Card
Fluke 2280A 2280A/162 20 Channel Isothermal Input
Card
For the Fluke 2280A Series Dataloggers
Fluke 2280A/162 Isothermal input connector with 20 channels for
thermocouples, DC voltage, or DC current. This is used in conjunction with a
2280A Series input module. For use in a FLU-228x mainframe. 20-channels
with 3-pole dry reed relay per channel. Requires 2280A-175 or 2280A-176 input
module. Many in stock.
|
| |
| |
Fluke
|
642587
|
Fluke 2280A 175 20 Channel Input Module
|
$100.00
|
|
|
Fluke 2280A 2280A/175 20 Channel Isothermal Input Module
Fluke 2280A 2280A/175 20 Channel Isothermal Input
Module
For the Fluke 2280A Series Dataloggers
Fluke 2280A/175 Isothermal input connector with 20 channels for
thermocouples, DC voltage, or DC current. This is used in conjunction with a
2280A Series input card. For use in a FLU-228x mainframe. Many in stock.
|
| |
| |
Fluke
|
2286A
|
Fluke 2286A Data Logging System
|
$250.00
|
|
|
Fluke 2286A/161 Datalogging System Mainframe
Fluke 2286A/161 Datalogging System Mainframe
Mainframe and 161 card only. No additional modules
Fluke 2286A Data Logging System
mainframe only. Requires plug in card to configure and signal condition.
Measures up to 100 channels per mainframe (expandable to 1,500 channels). DC
voltage and current, AC voltage, resistance, frequency, thermocouples, RTDs,
strain gauges, and event-totalizing. Employs pseudo-channel and math function
capabilities. 3.5-inch disk drive for data and program storage. Data output to
40-column internal printer, RS-232C, or disk drive. Fluke's most powerful
stand-alone data logger. Has 6 Slots for up to 6 Input/Output Option Cards PLUS
2 Slots for GPIB and/or RS232 Interface Cards. Built-in Printer. Each Analog
Input can Scan up to 20 Channels, Each Digital Input can Scan up to 20 TTL
Lines.
|
| |
| |
Fluke
|
2625A
|
Fluke 2625A Hydra Datalogger
|
$2,995.00
|
|
|
Fluke 2625A Hydra Datalogger
Fluke 2625A Hydra Datalogger
Rent me for $300 a month
The Hydra Series is available in three models to
fit many application requirements. The 2620A Hydra Data Acquisition Unit is a
compact front end for use with your PC. The portable 2625A Hydra Data Logger
features non-volatile memory that stores more than 2000 scans, for stand-alone
applications. And the 2635A Hydra Data Bucket with its removable memory card for
data and set-up storage is the most versatile model - ideal for remote
monitoring applications. All models are easy to set up and reconfigure from
the front panel. Additionally, all units have bi-directional communication via
RS-232C, which enables control from a host computer. The RS-232C interface also
supports stand-alone use with a serial printer. An optional GPIB/IEEE-488
interface is available for the 2620A only. The 2625A Hydra Series is extremely rugged and able to
operate in diverse environments. Its operating range is 0 to 60ºC, and it is
tested to stringent shock and vibration standards. Hydra's sturdy metal chassis
effectively shields against electromagnetic interference, maintaining high
measurement accuracy on low level signals. The analog circuitry is also isolated
from the digital circuitry so you can measure high voltages directly (up to 300V
ac rms). And it conforms to I.E.C., C.E. and CSA safety standards. What's more,
all set-up information is battery-backed, so it's immune to power failure. Hydra
will return from a power loss and resume scanning, while all configuration
information and stored data remain intact.
2625 Hydra Data Logger
- A low-cost alternative for stand-alone
monitoring operations.
- Internal memory
- A built-in nonvolatile memory that can store
more than 2000 scans.
- Flexible data retrieval
- The ability to upload stored data or transfer
real-time data via modem, or directly to your PC via the RS-232 port.
2625A Data Memory Specifications
- 2625A Data Storage Stores 2047 scans.
Scan Contents
- Memory life: 5 years minimum; at 25ºC
- Date and time stamp
- All defined analog input channel values
- Status of four alarm outputs and eight digital I/O Totalizer count
|
| |
| |
Fluke
|
2640A Netdaq
|
Fluke 2640A Netdaq Networked Data Acquisition
|
Contact Sales
|
|
|
Fluke 2640A Netdaq Networked Data Acquisition
Unit
Fluke 2640A Netdaq Networked Data Acquisition
Unit
Rent me for $400 a month
The Fluke 2640A and 2645A NetDAQ Networked Data Acquisition Units
are 20-channel front ends that operate in conjunction with NetDAQ Logger for
Windows (hereafter known as NetDAQ Logger) to form a data acquisition system.
The instruments measure dc volts, ac volts, Ohms, temperature, frequency, and dc
current. Temperature measurements use thermocouples or resistance-temperature
detectors (RTDs). To measure other parameters, use an appropriate transducer.
The instrument also includes ten computed channels for custom calculations based
on measured values. The NetDAQ instruments scan the 20 analog channels in
sequence and calculate the values for the ten computed channels. Interval
timers, alarm conditions, and/or an external signal input can trigger scans. The
NetDAQ Logger software configures and controls up to 20 instruments via an
Ethernet connection. The software provides the means to view scan data and log
it into files. The 2640A and 2645A instruments (Figure 1-1) are identical in
operation and appearance, and vary only in emphasis. The 2640A emphasizes
precision and supports up to 100 measurements per second, with 5 ½ digits of
resolution, .02% accuracy, and 150-volt common mode voltage (300 volts on
channels 1 and 11). The 2645A emphasizes increased measurement speed supporting
up to 1000 measurements per second, with 4 ½ digits of resolution, 0.04%
accuracy, and 50-volt common mode voltage.
Features
- 100, 50, 6 readings/second
- 18 bit A/D resolves 0.3 µV and .02°C
- 300V maximum measurement input
- Built-in signal conditioning
- Real time on-board clock
- -20 to 60°C (-4 to 140°F) operating temperature
Channel capacity
Analog inputs: 20
Computed channels: >10
Digital I/O and alarm outputs: 8 total
Totalizer: 1
Math functions
In addition to its 20
analog input channels, each NetDAQ unit supports 10
computed channels. Calculations include: addition,
subtraction, multiplication, division, log, natural log,
exponent, square root, absolute value, integer function,
and average.
Measurement speed (2640A)
Slow: 6 readings/second nominal
Medium: 41 (50 Hz), 48 (60 Hz)
readings/second nominal
Fast: 143 readings/second nominal
(5 readings/second for VAC nominal, 140 readings/second
on 300Ω range, 37 readings/ second on
3 MΩ range)
|
| |
| |
Fluke
|
2645A
|
Fluke 2645A Netdaq Networked Data Acquisition Unit
|
Contact Sales
|
|
|
Fluke 2645A Netdaq Networked Data Acquisition Unit Fluke 2645A Netdaq Networked Data Acquisition Unit Rent me for $500 a month NetDAQ Data Acquisition Units give you a powerful combination of hardware and software that's ideal for small-to-medium scale process monitoring and test systems. They answer the escalating need for measurement, recording, and analysis tools that enable you to improve quality, maximize process efficiency and meet regulatory requirements. Building blocks of 20 channels can be expanded into integrated systems of up to 400 channels. Choose between two models for speed up to 1000 rps and accuracy up to 0.01%. All NetDAQs utilize Fluke's patented Universal Input Module which accepts any combination of analog input types for each of its 20 channels - without the need for external signal conditioning. Simply pre-wire the Universal Input Module to directly measure temperature, dc volts, ac volts, resistance, 4-20 mA, and frequency. (For more information refer to the Universal Input Module in this section.) Distributed NetDAQ systems plug right into your existing networks to send data directly to a PC. This saves the cost of setting a new network and allows multiple users to simultaneously view data in real time. A NetDAQ unit can also be used as a portable dedicated system connected to a notebook computer for maintenance, product validation, research, and troubleshooting applications. Features - Data Acquisition, Up to 1,000 Readings Per Second
- 20 Analog Input Channels Expandable Up to 400 Channels
- Extensive Optional Plotting and Trending Capabilities
- Optional Wall, Cabinet, or Rack Mounting
- May Be Connected to Ethernet Networks
- Replaces Chart Recorders
System Configuration Set up your NetDAQ system the way you want it. You can set up your NetDAQ system in several different ways. Configure an isolated system, daisy-chaining as many as 20 NetDAQ units to your PC with a high-speed communication line. This is a quick, simple way to send real time data directly to a PC. Or, add NetDAQ units directly to your company's network. Sharing the network cabling and hardware that's already installed saves you time and expense. And, if you wish, all the users on your network have an easy way to access the data you're collecting. The Universal Input Module makes configuration a snap NetDAQ's Universal Input Module lets you easily measure just about any electrical or physical parameter without changing hardware or adding external signal conditioning. Any combination of dc voltage, ac voltage, thermocouples, current, RTD, resistance (2- or 4-wire), or frequency measurement can be connected directly to the input module. Fluke's proprietary signal conditioning capability is built directly into the NetDAQ unit, thus eliminating the need to purchase external conditioning modules. |
| |
| |
Fluke
|
2635A Hydra
|
Fluke Hydra 2635A Portable Data Acquisition System
|
$3,499.00
|
|
|
Fluke Hydra 2635A Portable Data Acquisition
System
Fluke Hydra 2635A Portable Data Acquisition
System
Rent me for $350 a month
2635A Hydra Data
Bucket
The ideal choice for gathering and transporting
large volumes of data and for working extended periods from remote locations.
The Fluke 2635A Hydra Series offers easy portability along with Fluke's built-in signal
conditioning and Universal Input Module at a price to fit your budget. You can
easily retrieve data from the Hydra units via the RS-232 interface, or through a
modem in upload or real-time mode. Flexibility
The Hydra Data Bucket comes equipped with a 256 KB
PCMCIA card and is also available with either a 1 MB, 2 MB, or 4 MB memory card
to suit your data storage needs. Data may be uploaded from these cards via the
2635A Hydra RS-232 port, the optional 263XA-803 memory card drive, or from your
computer's standard PCMCIA slot. Real-time data can be simultaneously
transferred to a PC at the same time it is recorded to the memory card. Quick setups
Simply push a few front panel buttons or load
instrument setups from the memory card. Fail-safe features
The Hydra Data Bucket gives advance indication of
a low battery or low memory condition on the memory card. Its internal memory
buffer continues to store up to 70 scans while the card is removed.
Universal Input Module
The removable Universal Input Module enables fast,
convenient set-up and reconfiguration. Any combination of dc voltage, ac
voltage, thermocouple, RTD, resistance, or frequency measurements can be
connected to the input module without the need for additional signal
conditioning. Thermocouple reference junction compensation is automatically
performed by sensing the temperature of the input module's isothermal block. For
applications with multiple measurement locations, purchasing additional input
modules provides the ability to quickly connect and disconnect a Hydra to these
various sites while leaving all sensor wiring intact. Portable Operation
The Fluke 2635A Hydra Data Bucket has been designed for
applications where data is gathered in a stand-alone manner "on
location" and later uploaded to a PC for analysis and/or archiving. Three
models of the Hydra Data Bucket are available with PC memory cards ranging in
size from 256K, 1 Mb, 2Mb and 4Mb in size. Up to 450,000 readings may be stored
on a 2M byte memory card. For applications where large amounts of data are
generated, you may swap memory cards without interrupting the Data Bucket's
scanning.
|
| |
| |
Fluke
|
Hydra Software
|
Fluke Hydra Logger for Windows Software
|
$499.00
|
|
|
Fluke Hydra Logger for Windows Software
Fluke Hydra Logger for Windows Software
Fluke Hydra Logger for Windows
The Hydra Logger for Windows software package
gives you a powerful data acquisition system when combined with a Hydra
instrument and your PC. Hydra Logger gives you control of Hydra's powerful
functions, including scanning, signal conditioning, sensor linearization, alarm
detection and reporting, non-volatile data memory, advanced trend plotting and
more. "Logger" supports the 2625A and 2635A Hydra models. With Hydra
Logger's optional, trend plotting package, Trend Link for Fluke, you can control
how your data is displayed. You can quickly scroll through real time and
historical data, or view data from all channels simultaneously, on a single
screen. Or, you can plot one or multiple channels in real time, even
superimposing channels on other channels. Zoom in and out features, and
statistics make this optional package ideal for report and analysis needs.
|
| |
| |
Fluke
|
2620A Hydra
|
Fluke Model 2620A Hydra Datalogger
|
$1,750.00
|
|
|
Fluke Model 2620A Hydra Datalogger
Fluke Model 2620A Hydra Datalogger
Rent me for $250 a month
Fluke 2620A Hydra
Data Acquisition Unit
The Fluke 2620AHydra is ideal for applications that require direct connection to a PC for
real-time data collection. The Hydra Series offers
easy portability along with Fluke's built-in signal conditioning and Universal
Input Module, at a price to fit your budget. You can easily retrieve data from
the Hydra units via the RS-232 interface, or through a modem in upload or
real-time mode. Channel information and measurement parameters can be set up
directly from the front panel or your PC. Three models featuring removable
memory card data storage, internal memory storage, and direct real-time data
transfer options. Should power fail, these instruments automatically resume data
collection when power is restored.
Easy-to-use front-end
An RS-232 serial interface makes it easy to connect the Hydra Data
Acquisition Unit to a PC or modem for real-time data acquisition. The 2620A
can also be used as a 20-channel panel meter.
IEEE interface
An IEEE-488 interface easily allows you to integrate the 2620A with other
IEEE-488 instruments and your PC. The 2620A delivers workhorse performance for
a wide variety of applications such as test and monitoring systems.
Universal
Input Module
The removable Universal Input Module enables fast, convenient set-up and
reconfiguration. Any combination of dc voltage, ac voltage, thermocouple, RTD,
resistance, or frequency measurements can be connected to the input module
without the need for additional signal conditioning. Thermocouple reference
junction compensation is automatically performed by sensing the temperature of
the input module's isothermal block. For applications with multiple
measurement locations, purchasing additional input modules provides the
ability to quickly connect and disconnect a Hydra to these various sites while
leaving all sensor wiring intact.
Hydra Logger Software
The Hydra Logger software package is included with each Hydra unit. It
gives you a powerful windows-based data acquisition system when combined
with a Hydra instrument and your PC. Hydra Logger gives you control of
Hydra's powerful functions, including scanning, signal conditioning, sensor
linearization, alarm detection and reporting, non-volatile data memory,
advanced trend plotting and more. Trend Link for Fluke
With Hydra Logger's optional, trend plotting package, Trend Link for
Fluke, you can control how your data is displayed. You can quickly scroll
through real time and historical data, or view data from all channels
simultaneously, on a single screen. Or, you can plot one or multiple
channels in real time, even superimposing channels on other channels. Zoom
in and out features, and statistics make this optional package ideal for
report and analysis needs.
|
| |
| |
Fluke
|
Trend Link Software
|
Fluke Trend Link Software
|
Contact Sales
|
|
|
Fluke Trend Link Software for the Hydra
Series Dataloggers
Fluke Trend Link Software
for the Hydra
Series Dataloggers
Trend Link is a comprehensive trend plotting and analysis package that
plots data graphically in real time. Trend Link allows you to quickly scroll
through real time and historical data, view data from all channels
simultaneously, compare real time data to an historical template in batch mode,
and superimpose selected channels for closer analysis. Any portion of a trend
may be examined more closely by utilizing Trend Link¿s Zoom function.
Trend Link for Fluke software enables you to easily access, view,
analyze and compare tremendous amounts of real time or historical data from any
Fluke data acquisition product, making paper chart recorders obsolete. Trend
Link is designed to make it easy to zoom in on data, review and compare
historical data to real-time data, compare batch processing operations, and
automatically view statistics on any channel.
|
| |
| |
Madgetech
|
Octtemp
|
Madgetech Octtemp 8 Channel Temperature Datalogger
|
Contact Sales
|
|
|
Madgetech Octtemp 8 Channel Temperature Datalogger Madgetech Octtemp 8 Channel Temperature Datalogger This 8-channel thermocouple based temperature recorder/datalogger is essential for monitoring temperature in multiple locations. It easily accepts 8 different thermocouple types J, K, T, E, R, S, B, and N. it is battery operated with a long life so it can be used in remote applications easily. 7 channels are data channels and 1 is reserved for ambient temperature. Power and light weight. Requires cable to connect to your PC. Different cable and connection options are available. The Madgetech Octtemp is a 8 channel, battery powered, standalone, thermocouple based temperature datalogger. This all-inone compact, portable, easy to use device will measure and record up to 14,563 temperature measurements per channel. The Madgetech Octtemp is a major leap forward in both size and performance. Its real time clock ensures that all data is time and date stamped. The storage medium is nonvolatile solid state memory, providing maximum data security even if the battery becomes discharged. Its small size allows it to fit almost anywhere. Data retrieval is simple. Plug it into an available COM port and our easy to use software does the rest. The software converts your PC into a real time strip chart recorder. Data can be printed in graphical or tabular format and can be exported to a text or Microsoft file. Specifications Internal Channel: 1 Temperature Accuracy: +0.5°C (0 to 50°C) Temperature Resolution: 0.1°C Temperature Range: -20 to 60°C (-4 to 140°F) Thermocouple Channels: 8 Thermocouple Input Types: J, K, T, E, R, S, B, N Thermocouple Connection: Subminiature female jack Cold Junction Compensation: Automatic External Thermocouple Channel Accuracy*: (uniform 20°C internal temperature): J, K, T, E: +0.5°C; R,S,B,N: +2.5°C Resolution: J, K, T, E: 0.1°C R, S, B, N: 0.5°C Temperature Measurement Range: Type J:-210 to 760°C; K:-270 to 1370°C; T:-270 to 400°C; E:-270 to 980°C; R:-50 to 1760°C; S:-50 to 1760°C; B:50 to 1820°C; N:-270 to 1300°C Memory: 14,563 readings/channel Temperature Calibration: Digital calibration is available through software Calibration Date: Automatically recorded within device to alert user when calibration is required Recording Interval: 5 seconds to 12 hours selectable in software Start Time: Start time and date are programmable through software Real Time Recording:Device maybe used with PC to monitor and record data in real time Power: 9 V lithium battery included; 120 Vac power optional Battery Life: 1 year typical Time Accuracy: ± 1 minute/month when RS-232 port is not in use Data Format: Date and time stamped, °C, °F, °K, °R, mV Computer Interface: PC serial, RS-232C COM or USB (interface cable required) Software: Windows 95/98/NT/2000/XP Operating Environment: -20 to 60°C (-4 to 140°F) 5 to 95% RH non-condensing Dimensions: 38 H x 111 W x 89 mmD (1.5x 4.4 x 3.5") Weight: 450 g (16 oz.) Material: Black anodized aluminum
|
| |
| |
Madgetech
|
PRTemp 1000IS
|
Madgetech PR1000IS Intrinsically Safe Pressure and Temperature Datalogger
|
$649.00
|
|
|
Madgetech PR1000IS Intrinsically Safe Pressure and Temperature Datalogger
Madgetech PR1000IS Intrinsically Safe Pressure and Temperature Datalogger
Intrinsically Safe (IS), pressure and ambient temperature data recorder, certified for use in hazardous and explosive environments. Rugged,
stainless steel enclosure is perfect for harsh, industrial applications and is completely submersible. Also features a ¼" NPT fitting for easy connection to gas,
water, steam and hydraulic pressure lines. Temperature and Pressure data may be displayed, with time and date stamps, in standard and metric units. Available in several
pressure ranges, Absolute (A) and Gauge (G). Requires additional operating software USB option $119 than can be used for multiple units.
Range (PSI)
- 0-30
- 0-100
- 0-300
- 0-500
- 0-1000
- 0-5000
Accuracy
2%
- FSR, 0.25% @ 25°C Typical
Specifications
- Temperature Range:
-40~+80°C
- Memory:
16,383/channel
- Sample Rate:
2 seconds up to 12 hours
|
| |
| |
Reed
|
8829 Kit
|
New Reed 8829 Low Cost Temperature and Humidity Datalogger
|
$165.00
|
|
|
New Reed 8829 Low Cost Temperature and Humidity Datalogger
New Reed 8829 Low Cost Temperature and
Humidity Datalogger
The Reed 8829 is an ultra compact data logger that records the temperature
and humidity readings for days,
weeks, even months. Look at the incredibly low cost. If you need a low cost
solution you can not beat this. This cost includes the required Reed 8818
communications kit with software and cables required for operation.
Features
- °F or °C selectable
- LCD display
- Logs data for days,
weeks or months
- Programmable
sampling rate from
1 second to 2 hours
- Three start modes:
scheduled,
immediate or magnetic
- Records up to 16,000
readings
- Real-time clock
stores data and time
- Data is retained in
non-volatile
memory
- User-defined min/max
alarm settings
- Program by RS-232
serial port and
Windows® compatible software
- 60 inch cable with DB9
connector
- Optional data logger
kit (includes docking station, RS-232 cable and Windows® compatible software) and battery
operated
printer available
-
Humidity Range: 0
to 100% RH
Temperature Range:
32 to 185° F
(0 to 85°C)
Temperature Range:
-40 to 185°F (-40 to 85°C)
|
| |
| |
Reed
|
C-342/345
|
New Reed C-342/345 Temperature/Humidity Data Logger
|
$195.00
|
|
|
New Reed C-342/345 Temperature/Humidity Data Logger
New Reed C-342/345 Temperature/Humidity Data
Logger
Easy to use data logger records up to 64,000 temperature
and humidity readings.
Features
- °F or °C selectable
- LCD display with LED backlight
- 32,000 records per channel
- Real-time clock stores data and time
- Memory status and battery status displays
- Program by ¿Slim-Com¿ RS-232 interface and Windows®
compatible software
- Shipped with wall hanging tag
- Includes model 345 communication base
- Temperature Range: -22
to 158°F (-30 to 70°C)
- Resolution: 0.1°F
(0.1°C)
- Accuracy: ±0.7°C
- Humidity Range: 5 to
98% RH
- Resolution: 0.1% RH
- Accuracy: ±3% RH
- Power Supply: 2 x 1.5V
AAA batteries
- Dimensions: 92 x 55 x
22mm
|
| |
| |
Reed
|
THR-1
|
New Reed THR-1 7 Day Temperature and Humidity Recorder
|
$525.00
|
|
|
New Reed THR-1 7 Day Temperature and Humidity Recorder
New Reed THR-1 7 Day Temperature and Humidity
Recorder
Simultaneously records ambient temperature and relative humidity
conditions on paper charts. Ideal for situations requiring hard copy
documentation of temperature and humidity such as laboratories, hospitals,
museums, art exhibits and nuclear facilities.
Features
-
Choice of 1-day or 7-day models
-
Bi-mettalic coil temperature sensor and de-fatted hair
humidity sensor
-
Provides maximum and minimum values
-
Humidity Range: 30 to 100% RH
-
Resolution: 1-day: 1% RH/15 min.; 7-day: 1% RH/1 hour
-
Accuracy: 1-day: ±5% RH/5 min.; 7-day: ±5% RH/30 min.
-
Temperature Range: -15 to 40°C
-
Resolution: 1-day: 1°C/15 min.; 7-day: 1°C/1 hour
-
Accuracy: 1-day: ±1°C/5 min.; 7-day: ±1°C/30 min.
|
| |
| |
Reed
|
THR-2
|
New Reed THR-2 7 Day Temperature and Humidity Recorder
|
$525.00
|
|
|
New Reed THR-2 7 Day Temperature and Humidity Recorder
New Reed THR-2 1 Day Temperature and Humidity
Recorder
Simultaneously records ambient temperature and relative humidity
conditions on paper charts. Ideal for situations requiring hard copy
documentation of temperature and humidity such as laboratories, hospitals,
museums, art exhibits and nuclear facilities.
Features
-
Choice of 1-day or 7-day models
-
Bi-mettalic coil temperature sensor and de-fatted hair
humidity sensor
-
Provides maximum and minimum values
-
Humidity Range: 30 to 100% RH
-
Resolution: 1-day: 1% RH/15 min.; 7-day: 1% RH/1 hour
-
Accuracy: 1-day: ±5% RH/5 min.; 7-day: ±5% RH/30 min.
-
Temperature Range: -15 to 40°C
-
Resolution: 1-day: 1°C/15 min.; 7-day: 1°C/1 hour
-
Accuracy: 1-day: ±1°C/5 min.; 7-day: ±1°C/30 min.
|
| |
| |
Reed
|
200TC
|
Reed 200TC Wireless Multiple Temperature
|
$1,255.00
|
|
|
Reed 200TC Wireless Multiple Temperature
Monitoring System for Food Service Applications
Reed 200TC Wireless Multiple Temperature
Monitoring System
Precise, wireless temperature monitoring for food safety and
other applications. Includes 6 separate remote transmitters, 4 cold probes, 2
hot probes and software. You get an impressive system. Designed for food service
but usable in other applications. Provides datalogging of temperature and remote
monitoring of results. Perfect for multishift operations. Records and stores
results to download to your PC.
Features
-
Temperature data is automatically retrieved every 15
minutes around the clock, every day...24/7 and the information is
stored for 10 days
-
Maximum and minimum temperature control points can
be programmed into the monitor for each sensor
-
Visual (red flashing light) and audible (90 dB
beeper) alarms
-
Five different alarm delay settings (0, 15, 30, 45
or 60 minutes)
-
Data collected is easily uploaded to a PC via
integral USB port
-
Tamperproof log sheets are created in Excel for
storage and graphing
-
Monitors current temperatures from up to 30 remote
temperature sensors
-
Temperature information is sent wirelessly up to
300' (100m)
-
All sensors are waterproof to IP65 and all
components meet NSF criteria for professional kitchen equipment
-
"Hot" and "cold" probes with standard 6' (2m) cables
available
-
Kit includes six 201TC wireless transmitters, each
with wall mount bracket, four 203TC "cold" probes (blue) and two
202TC "hot" probes (red), and 209TC software and USB cable
Monitor
-
Temperature Range: -20 to 300°F
-
Data Update Time: 15 minutes
-
Memory Capacity: 2 days for 30 temperature sensors;
10 days for 6 temperature sensors
-
Alarms: 80 - 90 dB beeper sounds and red light
flashes every 10 seconds when temperatures are outside "safe range"
-
Power Supply: 120V AC/DC, 15mA adapter included, 4 x
"AA" battery back up
-
Dimensions: 7 x 1.1 x 5.5"
Transmitter
-
Probe Temp. Range: Cold: -20 to 140°F; Hot: 50 to
300°F
-
Alarms: 80 - 90 dB beeper sounds and red light
flashes every second
-
when temperatures are outside "safe range"
-
Transmission Range: 300 ft. (100m) in an open area
-
Power Supply: 3 x "AAA" batteries
- Dimensions: 2 x 3 x 0.75"
|
| |
| |
Reed
|
ST-173
|
Reed ST-173 USB Sound Level Datalogger
|
$139.00
|
|
|
Reed ST-173 USB Sound Level Datalogger
Reed ST-173 USB Sound Level Datalogger
A small sound level datalogger plugs directly into your
computer. Compact and easily carried by people for sound level studies.
Incredible product for the money
Features
-
Conforms to IEC61672-1 Class 2 sound level
meters
-
1/2" electret condenser microphone
-
A and C frequency weighting
-
Fast and Slow time weighting
-
Normal (average of 20 data samples) and Peak
modes
-
Max and Min measurements
-
User selectable sampling intervals
-
Data storage capacity of 129,920 samples
-
Integral USB port
-
Includes: Microphone windscreen, transparent
cap, software CD, metal support stand and batteryMeasuring
Range: 30 to 130 dB
-
Accuracy: ±1.4 dB
-
Frequency Range: 31.5 Hz to 8 kHz
-
Time Weighting: Fast: 125ms; Slow: 1s
-
Sampling Intervals: Selectable from 1 second
to 24 hours
-
Power Supply/Battery Life: 1 x 3.6V
battery/Approx. 200 hours
- Dimensions: 144 x 27 x 14mm
|
| |
| |
Sony Data Recorders
|
PCCK21
|
Sony PCCK21 Synchronization Cable
|
$199.00
|
|
|
Sony PCCK21 Synchronization Cable
Sony PCCK21 Synchronization Cable
Synchronization cable for the SIR
series data recorders. Allows multiple units to be synchronized together.
|
| |
| |
Sony Data Recorders
|
PCIF-200A
|
Sony PCIF-200A Computer Interface
|
Contact Sales
|
|
|
Sony PCIF-200A Computer Interface
Sony PCIF-200A Computer Interface
The Sony PCIF-200A is a high
speed interface that converts your Sony PCxxx series data recorders into an
extremely high speed data acquisition system. The storage is only limited by the
size of the available hard drive. This allows the benefit of direct transfer of
with the accuracy of the Sony front end. This is a kit including software,
connecting boards and cables.
|
| |
| |
Sony Data Recorders
|
PCRM21AX
|
Sony PCRM21AX Remote Control
|
$495.00
|
|
|
Sony PCRM21AX Remote Control
Sony PCRM21AX Remote Control
External Remote Control for the
SIR series data recorders. Allows remote operation and includes data input level
monitoring.
Features
- Display: Bar graph(up
to 8ch)
- Tape position data
- Alarm display
- Control: REC, STOP,
FWD, FF, REW, PAUSE, search, ID increment, counter reset Interface
- RS-232C Cable length:
3 m (9' 10")
- Dimensions:
210(W)x25(H)x70(D) mm [8.3"x1.01"x 2.8")excluding projections
- Weight: Approx. 0.5kg
(1.1 lbs)
|
| |
| |
Sony Data Recorders
|
SCX-32I
|
Sony SCX-32I 16 Channel Expansion Chassis w/ICP for the SIR-1000I
|
Contact Sales
|
|
|
Sony SCX-32I 16 Channel Expansion Chassis w/ICP for the
SIR-1000I
Sony SCX-32I 16 Channel Expansion Chassis w/ICP
for the SIR-1000I
Rent me for $400 a month
The Sony SCX-32I is an expansion unit for SIR-1000I. Up to 128
channels (7 expansion units) can be connected a single SIR-1000i. Bandwidth is
to 20 kHz. Designed to add the capability to power ICP sensors.The SCX-32I has
built-in ICP power supply, which enables direct connection with ICP sensors.
This function saves space at a recording site, making the SCX-32I a perfect fit
in field recording applications. Input mode is switchable between sensor and
direct voltage, latter of which is SIR-1000's standard. Type of input mode is
recorded on tape along with other auxiliary information such as input range and
time code and is displayed on play back.
Features
-
Selectable input mode SENSOR or DIRECT
-
Extended input range
-
For SENSOR input : ±0.1, 0.2, 0.5, 1, 2, 5, 10Vpk/7 steps
-
For DIRECT input : ±0.1, 0.2, 0.5, 1, 2, 5, 10, 20Vpk/8 steps
-
Compatible with SIR-1000. Data recorded on the SIR-1000 can be
played back on the SIR-1000i and vice versa.
-
Indicators : Colored LEDs for SENSOR input modes and warning
indication.
The Channel Expansion Units feature excellent portability
and a design that allows integration with the SIR-1000 Series by using a
combined frame. In addition, the expansion unit can be mounted below the
SIR-1000 Series in an EIA standard 19" rack by using the SRT-10/20 dedicated
rack mount adapters option A multi-channel configuration can be achieved inside
vehicles and other restricted spaces by using the SHL-64/-128 dedicated stacking
frames. This makes it possible to configure 32 to 128 channel configurations
with the smallest space and overall weight of any data recorder in this class.
|
| |
| |
Sony Data Recorders
|
SIR-1000
|
Sony SIR-1000 16 Channel Data Recorder
|
Contact Sales
|
|
|
Sony SIR-1000 16 Channel Data Recorder
Sony SIR-1000 16 Channel Data Recorder
Rent me for $1000 a month
The Sony SIR-1000 is a high speed digital data
recorders that utilise AIT (Advanced Intelligent Tape) technology. It is a
16-channel, high-speed digital data recorder suitable for data recording in the
field or laboratory. Frequency Response is from DC to 20 kHz for 16 or 32
channels (see SCX-32 for 16-channel expansion). 2 to 32 hour recording and
playback with variable tape speeds. Over 80 dB dynamic range; 16-bit linear
quantization. Equipped with BNC single-ended analog input connectors. Data can
be stored, downloaded to a PC or replayed in real-time. High quality data
recordings from the best in the industry.
Features
- AIT Media - 25GB and 2-32 hours recording duration per tape
- Input ranges from ±0.1V to ±20V. (ICP® facility SIR-1000i)
- Bandwidths up to 20kHz on a maximum of 32 channels using a
Channel Expansion Unit
- 16-128 Channels (20kHz - 5kHz)
- 90-250VAC, 9-32VDC and Battery Powered
- >80dB Dynamic Range
- Lightweight and Portable
|
| |
| |
Sony Data Recorders
|
SIR-1000I
|
Sony SIR-1000I 16 Channel Data Recorder with ICP
|
Contact Sales
|
|
|
Sony SIR-1000I 16 Channel Data Recorder with ICPI
Sony SIR-1000I 16 Channel Data Recorder with
ICPRent me for $1200 a
month
The SIR-1000i has built-in ICP
power supply, which enables direct connection with ICP sensors. This function
saves space at a recording site, making the SIR-1000i a perfect fit in field
recording applications. Input mode is switchable between sensor and direct
voltage, latter of which is SIR-1000's standard. Type of input mode is recorded
on tape along with other auxiliary information such as input range and time code
and is displayed on play back. The SIR-1000I in basic
configuration features a 20kHz bandwidth for all 16 channels. In addition, 32
channels of DC to 20kHz analog data can be simultaneously recorded on a single
data cartridge by combining the recorder with an optional SCX-32/SCX-32i Channel
Expansion Unit. The number of channels can be further increased by adding
channel expansion units. 128 channels of 5kHz analog data can be recorded with a
system consisting of the SIR-1000/SIR-1000i and seven SCX-32/SCX-32i.
Features
-
Selectable input mode SENSOR or DIRECT
-
Extended input range
-
For SENSOR input : ? 0.1, 0.2, 0.5, 1, 2, 5, 10Vpk/7 steps
-
For DIRECT input : ? 0.1, 0.2, 0.5, 1, 2, 5, 10, 20Vpk/8 steps
-
Compatible with SIR-1000. Data recorded on the SIR-1000 can be played
back on the SIR-1000i and vice versa.
-
Indicators : Colored LEDs for SENSOR input modes and warning
indication.
The PCM system provides a dynamic range
of 80 dB or more (SIR-1000/-1000i) through 16-bit linear quantization and
independent AD/DA conversion for each channel. This not only allows extremely
accurate data recording but also facilitates the input range settings. In
addition, the adoption of 64 ?~ oversampling digital filters provides nearly
linear phase characteristics and achieves an inter-channel phase difference of
less than 1 degree (SIR-1000/SIR-1000i). The analog input level has an allowable
range of up to 133% of the full scale range setting. The analog characteristics
specified in this data sheet are for up to 133%. And the input DC offset can
also be adjusted within the range of ? 100%. The analog output level can be
selected from 1 Vpk, 2 Vpk or 5 Vpk (calibrated output ), or from ? 0.5 to
5 Vpk (continuous variable output). |
| |
| |
TEAC
|
RD-101T
|
Teac RD-101T 4 Channel PCM Data Recorder
|
Contact Sales
|
|
|
Teac RD-101T 4 Channel PCM Data Recorder Teac RD-101T 4 Channel PCM Data Recorder Rent me for $300 a month
with options
- TZ-313FA Anti aliasing Filter
-
Uses Standard DAT Tapes
Features High-quality data (accuracy) - The quadruple oversampling digital filter is used as the output stage in the multiplex PCM recording method. The signal-to-noise ratio is 70 dB. The frequency characteristic flatness is +0.5 dB, -1 dB. The phase difference between channels is 5° (fmax).
Multi-channels and wide band - The RD-101T uses a 2-channel/4-channel switching system. The band for 2-channel recording is 20 kHz and the band for 4-channel recording is 10 kHz.
Small and compact - The data recorder is approximately 306 mm wide x 100 mm high x 307 mm deep, and weighs approximately seven kilograms. The data recorder is therefore very portable.
Long recording time - When a 120 tape (approximately 60 m) is used, data can be recorded continuously for two hours.
Three power supplies - Operates on either AC input of 90-130 (180-250) volts, DC input of 11-30 volts, which are provided normally, and an optional rechargeable battery unit. The battery unit can be incorporated by mounting it on the data recorder. Since the battery charge function is built into the data recorder and protection for battery over-discharging is provided, the RD-101T can be used both indoors and outdoors.
Easy operation (condition setting is unnecessary) - The input range is fixed to eliminate the need for complicated range setting. The purpose of this function is to approach the absolute value recording by making the input and output voltages equal:
Memo sound channel - In addition to the data channels, a channel used only for voice recording and reproduction is provided. Since the microphone built into the data recorder is provided normally for recording, environmental sounds can always be recorded during measurement.
Time code recording channel - In addition to the data channels, a channel used only for recording and reproduction of time codes is built in. The year, month, day, hours, minutes, and seconds of the built-in clock with perpetual calendar are automatically recorded. Since the time code is always automatically recorded, it can be used to confirm the recording time of measurement data on the display.
Data number (ID number) recording channel - In addition to the data channels, a channel used only for recording and reproduction of ID numbers is built in. The ID number of the recorded data is automatically recorded. The ID number is incremented by one each time recording starts or the EVENT button is pressed.
High-speed search - The recorded ID number can be searched for at high speed during reproduction. The search is performed both in the forward and reverse directions. When the target ID number is found, the target data is reproduced from the beginning.
Pressing the PAUSE button during search causes the tape to pause at the beginning of the data when the search ends.
|
| |
|
Test Equipment, test eqipment, test and measurement, US INSTRUMENT SERVICES, rental, sales, used, HP, Hewlett Packard, Tektronix, tektronics, TEK, CSI, Campbell, oscilloscopes, ossiliscopes, optical, fiberoptic, Telecom, test sets, network, logic, B&K, Bruel, Kjaer, Dranetz, Telecom, TTC, Wandel, Goltermann, spectrum analyzers, logic analyzers, digital, multimeters, counters, data acquisition, HiPot, meggers, ground testing, protocol, pirateracing, butch
|
©1999-2002 [fill in company name] All Rights Reserved |
contact
webmaster
| powered by
corezon
|
|
All logos and trademarks are properties of their respective companies. Product price,
specification, warranty and availability subject to change without notice.
|
|
|