AEMC
|
SDL-402
|
AEMC Sentinel SDL-402 AC/DC Current Datalogger
|
Contact Sales
|
|
|
AEMC Sentinel SDL-402 AC/DC Current Datalogger
AEMC Sentinel SDL-402 AC/DC Current Datalogger
Rent me for $300 a month
The Sentinel Current Logger Model SDL A402 is a four-channel
current logger recording device designed for use with AEMC detachable current
probes . The Model SDL A402 is powered with rechargeable NiMH batteries.
Real-time display of waveforms and harmonics is available with the DataView
software, which is included. Programmable storage rate and storage modes,
combined with simple one button operation, make this a versatile and easy-to-use
data logger, perfect for a variety of applications.
Features
True RMS current measurements
DC current measurements when used with Hall Effect Current Probes on
Model SDL A402
Low-cost, self-contained, portable
Measures up to 1000A (probe dependent)
Programmable storage mode
Programmable storage rate
Records up to 480,000 measurements (1MB)
64 samples per cycle
Includes DataView® software
Optically isolated USB 2.0 communication
Detachable current probes
600V Cat. III, 300V Cat. IV
Applications
Load profiling
Energy management
Preventative maintenance
Stray current monitoring
|
| |
| |
Agilent / HP
|
34901A
|
Agilent 34901A 20 Channel Input Module
|
$425.00
|
|
|
New Page 1
Agilent 34901A 20 Channel Input
Module for 34901A series dataloggers.
The Agilent 34901A module for the 34970A Data Acquisition/Switch Unit is the
most versatile multiplexer for general purpose scanning. It combines dense,
multi-function switching with 60 channel/second scan rates to address a broad
spectrum of data acquisition applications. Two and four-wire channels can be
mixed on the same module. Two additional fused inputs (22 channels total) route
up to 1A of current to the internal DMM, allowing ac and dc current measurements
without the need for external shunt resistors. Excellent general purpose module.
Agilent has very long delivery dates. We have it in stock today!
20-Channel General-Purpose
Multiplexer
|
| |
| |
Agilent / HP
|
34903A
|
Agilent 34903A 20 Channel Input Module
|
$299.00
|
|
|
34903A 20 Channel
Actuator/ Switch Module
The Agilent 34903A is a general-purpose switch module for the 34970A
Data Acquisition/Switch Unit. It has 20 independent single-pole,
double-throw (SPDT) relays and is used to cycle power to products under
test, control indicator and status lights, and to actuate external
power relays and solenoids. Combine it with matrix and multiplexer
modules to build custom switch systems. Its 300 V, 1 A contacts can
handle up to 50 W, enough for many power line switching applications.
Features
- 20 Channel Actuator/GP Switch
- SPDT (Form C) latching relays
- 300 V, 1 A actuation and control
|
| |
| |
Agilent / HP
|
34902A
|
Agilent 34902A 16 Channel Multiplexer
|
$449.00
|
|
|
New Page 1
Agilent 34902A 16 Channel Multiplexer
(2/4-wire) Module for 34970A
Rent me for $75 a month
The Agilent 34902A module for the 34970A Data Acquisition/Switch
Unit employs reed relays to achieve scan rates up to 250 channels-per-second.
Use this module for high-throughput automated test applications as well as
high-speed data logging and monitoring tasks.
Sixteen two-wire inputs switch up to 300 V. Two-and four-wire
channels may be mixed on the same module. User provided shunt resistors are
required for current measurements.
Features
- 16 Channel Multiplexer
- 250 ch/s scanning
- Two- and four-wire scanning
- Built-in thermocouple reference junction
Multiplexer Selection Guide
Choose between the broad functionality of the 34901A, the high
speed scanning of the 34902A, or the single-ended density of the 34908A. These
three modules are the only way to connect to the 34970A internal DMM. They can
be used to scan with external instruments as well. All multiplexer modules
employ break-beforemake scanning, ensuring only one closed channel (or channel
pair) at a time. Multiple channel closures are allowed on the 34901A and 34902A
modules when not configured for scanning. The 34908A does not allow multiple
channel closures at any time.
Up to three modules, in any combination, can be inserted into a
single mainframe. The 34970A?s internal DMM connections are accessible only
through the 34901A, 34902A, and 34908A low frequency multiplexers. On-module
screw terminals accept wire sizes from 16 gage to 22 gage. Twenty-gage wire is
recommended for high channel count applications. The 34905A and 34906A RF
Multiplexers use SMB connectors. A standard set of (10) BNC-to-SMB adapter
cables is provided with each RF module for convenient BNC connections.
|
| |
| |
Agilent / HP
|
34907A
|
Agilent 34907A Multifunction Module
|
$320.00
|
|
|
Agilent 34907A
Multifunction Module
Features
- 16 bits of digital input and output
- 100 kHz totalizer input
- Two ±12V analog outputs
The Agilent 34907A module for the 34970A Data
Acquisition/Switch Unit allows great flexibility for a variety of sense
and control applications. It combines two 8-bit ports of digital input
and output, a 100 kHz gated totalizer, and two ±12V analog
outputs - all on a single earth-referenced module. The digital inputs
and totalizer input may be included in a scan. Alarm limits for the
digital and event counter inputs are evaluated continuously, capturing
and logging alarm conditions even between scans.
Digital Input/Ouput
Use the digital outputs with an external power supply
to control microwave switches and attenuators, solenoids, power relays,
indicators, and more. Use the digital inputs to sense limit switch and
digital bus status. There are no complex handshake modes; reads and
writes are initiated either from the front panel or the bus.
Totalize Input
Count events from devices like photo interrupters,
limit switches, and Hall-effect sensors.
It keeps an updated total which can be read via the
front panel or programmatically at any time. With 26 bits of
resolution, it can count events at full speed for nearly 45 minutes
without an overflow.
Analog Output
Use the two electronically calibrated analog outputs to
source bias voltages to your device under test, to control your analog
programmable power supplies, or use the outputs as setpoints for your
control systems. The outputs are programmed directly in volts, either
from the front panel or from the bus.
|
| |
| |
Agilent / HP
|
34970A
|
Agilent 34970A Datalogger Mainframe
|
$1,249.00
|
|
|
Agilent 34970A Datalogger Mainframe
Agilent 34970A Datalogger
Mainframe
Rent me for $150 a month for base unit only
Requires additional plug in modules for
operation
The best and easiest datalogger to use. No hassles or grief. Fast quick
results. Requires plug in modules for your application. The Agilent 34970A
consists of a three-slot mainframe with a built-in 6 ½ digit DMM. Each channel
can be configured independently to measure one of 11 different functions
without the added cost or hassles of signal-conditioning accessories. Choose
from eight optional plug-in modules to create a compact data logger,
full-featured data acquisition system or low-cost switching unit. On-module
screw-terminal connections eliminate the need for terminal blocks and a unique
relay maintenance feature counts every closure on every switch for easy,
predictable relay maintenance. Our most popular module 34901A features a
built-in thermocouple reference and 20 two-wire channels.
Features
- 3-slot mainframe with built-in GPIB and RS232 interfaces
- 6 ½-digit (22-bit) internal DMM, scanning up to 250
channels per second
- Built-in Signal conditioning measures thermocouples,
RTDs, & Thermistors, ac/dc Volts, & Current; Resistance; Frequency
and Period
- 8 switch and control plug-in modules to choose from
- 50k readings of non-volatile memory holds data when
power is removed
- Hi/LO alarm limits on each channel, plus 4 TTL alarm
outputs
Plug ins available include
34901A 20-CH multiplexer (2/4-wire) 60
300 V 1 A 2 current channels (22 ch total) Built-in cold junction reference
34902A 16-CH multiplexer (2/4-wire) 250
300 V 50 mA Built-in cold junction reference
34903A 20-CH actuator/GP switch 120 300
V 1 A Form C (SPDT) switches
34904A 4x8 matrix 120 300 V 1 A 2-wire,
full crosspoint
34905A 2-GHz dual 1:4 RF mux, 50 ohm 60
42 V 0.7 A 1-GHz through provided BNC-to-SMB adapter cables
34906A 2-GHz dual 1:4 RF mux, 75 ohm 60
42 V 0.7 A 1-GHz through provided BNC-to-SMB adapter cables
34907A 2 8-bit digital I/O ports;
26-bit, 100-kHz event counter; 2 16-bit analog outputs 42 V; 42 V; +/-12 V 400
mA; ; 10 mA Open drain; Gated, selectable input threshold; Earth referenced.
Calibrated.
34908A 40-CH single-ended multiplexer 60
300 V 1 A Common low, no 4-wire meas. Built-in cold junction reference
|
| |
| |
Agilent / HP
|
34906A
|
Agilent 39406A 75 Ohm RF Switch
|
$500.00
|
|
|
Agilent 34906A 75 Ohm RF
Switch
In stock today!.
The Agilent 34906A RF multiplexer module for the 34970A Data
Acquisition/Switch Unit offers broadband switching capabilities for
high-frequency and pulsed signals. Use it to route test signals between
your device under test and your signal generator, oscilloscope,
spectrum analyzer, or other instrumentation. The RF multiplexers are
arranged as two independent 1 x 4 multiplexers, each with a common
shield and a switched center conductor. Connections can be made
directly to SMB inputs with 2 GHz usable bandwidth, or to the
BNC-to-SMB adapters provided with 1 bandwidth. Multiple banks may be
cascaded together for applications requiring even larger
topologies--create a stubless 16:1 multiplexer in a single frame.
Features Dual 4 Channel RF Multiplexer 2 GHz bandwidth, 75 Ohm BNC to
SMB adapter cables included
|
| |
| |
Agilent / HP
|
44473A
|
Agilent/HP 44473A 4x4 Two-Wire Matrix Switch
|
Contact Sales
|
|
|
Agilent/HP 44473A 4x4 Two-Wire Matrix Switch
Agilent/HP 44473A 4x4 Two-Wire Matrix
Switch
Rent me for $100 a month
For the 3488A Switch/Control Unit
The 44473A offers highly flexible switching with a 4 X 4, 2-wire
matrix. Any combination of 4 input channels may be connected to any
combination of 4 output channels. Each cross point or node in the matrix
uses a 2SPST relay to switch 2 lines (Hi and Lo) at a time. Multiple 4 X 4
modules can be connected to form larger matrices. Multiplexers can be used
in conjunction with this larger module to effectively expand the number of
inputs and outputs of the matrix.
Input Characteristics
8
Maximum Voltage: 250V
Maximum Current:
Per channel: 2A, Per module: 8A
Maximum Power:
Per channel: 60W; 125VA, Per module: 240W;500VA
Initial Closed Channel Resistance: <1 Ohm
DC Isolation (<40°C, <60%RH)
AC Isolation
|
| |
| |
Agilent / HP
|
3488A
|
Agilent/HP 3488A Switch/Control Unit
|
$100.00
|
|
|
Agilent/HP 3488A Switch/Control Unit
Agilent/HP 3488A Switch/Control Unit
Requires additional modules for operation
The Agilent/HP 3488A Switch/Control Unit brings versatile, HP-IB programmable
switching to tests requiring multi-channel measurements. The Agilent/HP
3488A provides single switching with the integrity and isolation needed for
high-performance production test systems. It also offers a flexible,
low-cost interconnection for automating experiments on the bench and for
developing tests in the lab. The Agilent/HPHP 3488A is designed to hold up
to 5 of the following switch and control modules:
Features
- DC-26.5 signal switching
- Matrix, multiplexer, and general purpose relays
- Digital I/O control and actuation
- Up to 50 channels
- 40 configuration storage registers
- 11 switch and control modules
Flexible Switching
The Agilent/HP 3488A is an economical approach to flexible switching through
plug-in modules. You can select the right combination of switching
functions to meet both performance and budget needs. Testing is simplified
by having one solution for connections of low-level DVM inputs, high-level dc
and ac power, and microwave signals to 26.5 GHz. Additional devices, such
as microwave relays and programmable attenuators, are easily controlled with
digital I/O functions. Custom circuitry can also be implemented on
breadboard modules.
Versatile Performance
The Agilent/HP 3488A can store up to 40 complete switch configurations for
convenient recall in automated test programs. Switch operation can be done
with multiple relay closures or with selectable channels in a break-before-make
mode. Break-before-make and recallable switch configurations can be
combined in a programmable scan list. The Agilent/HP 3488A uses removable
screw connectors that provide easily interchangeable wiring for each test.
Built-in self-test assures proper operation.
|
| |
| |
Agilent / HP
|
34908A
|
Agilent/HP 34908A 40 Channel Single-Ended Multiplexer Module
|
Contact Sales
|
|
|
Agilent/HP 34908A 40 Channel Single-Ended Multiplexer Module
Agilent/HP 34908A 40 Channel Single-Ended
Multiplexer Module
Use the Agilent 34908A module for the 34970A Data
Acquisition/Switch Unit for the greatest density in common-low applications,
such as battery test, component characterization, and bench top testing. Each
module switches 40 one-wire inputs. All two-wire internal measurements except
current are supported. The module low connection is isolated from earth and can
float up to 300 V.
Features
- 40 Channel Single-Ended Multiplexer
- 60 ch/s scanning
- Single-wire switching for common-low applications
- Built-in thermocouple reference junction
|
| |
| |
Agilent / HP
|
44470A
|
Agilent/HP 44470A Multiplexer
|
$100.00
|
|
|
Agilent/HP 44470A Multiplexer
Agilent/HP 44470A
Multiplexer
For the 3488A Switch/Control Unit
Option 010 is a 10-channel multiplexer for scanning or multiple signal
connections. Channels switch 2 wires (Hi and Lo) with 2 PST relays for DVM
inputs and other signals up to 250V and 2A. This module can also be used to
multiplex signals to other switching functions, such as the matrix module.
|
| |
| |
Agilent / HP
|
44471A
|
Agilent/HP 44471A General Purpose Relay
|
$100.00
|
|
|
Agilent/HP 44471A Switch/Control Unit
Agilent/HP 44471A General Purpose Relay
For the 3488A Switch/Control Unit
This module consists of 10 SPST independent relays for general signal
switching and control of external devices. Quality connections make this module
ideal for switching signals when multiplexing is not required, or for supplying
switchable power to the device under test.
|
| |
| |
Agilent / HP
|
44472A
|
Agilent/HP 44472A Dual 1x4 VHF Multiplexer
|
$199.00
|
|
|
New Page 1
Agilent/HP 44472A Dual 1x4 VHF Multiplexer
The Agilent 44472A VHF module offers broadband switching capability for high
frequency and pulse signals. Two independent 50 Ohm character impedance
bi-directional 1x4 switches are provided for signals from DC to 300 MHz. Very
low crosstalk makes the VHF module ideal for VHF signal measurements using
spectrum, network, or distortion analyzers. You can also use the excellent
signal integrity of the VHF module for multiplexing inputs to your GPIB
oscilloscope or waveform analyzer. Each group of four channels is isolated from
the other and from the chassis to prevent ground loops. BNC connectors provide
ease of connection to the module.
Features
- DC to 300MHz
- BNC connectors for ease of wiring
- For 3488A & 3499A/B/C Mainframes
The 2 independent groups of bidirectional 1 X 4 switches can be
used for signals from dc to 300 MHz. All channels have 50-ohm characteristic
impedance and are break-before-make within a group of 4 channels. Each group is
isolated from the other and from ground to prevent ground loops. Excellent
isolation makes this module ideal for high-frequency signal analyzer
measurements requiring a large dynamic range.
|
| |
| |
Agilent / HP
|
44474A
|
Agilent/HP 44474A Digital I/O
|
$100.00
|
|
|
Agilent/HP 44474A Digital I/O
Agilent/HP 44474A Digital I/O
For the 3488A Switch/Control Unit
This module offers 16 very flexible bidirectional I/O lines and 4 TTL-compatible
handshake lines for sensing and control of external devices. The digital inputs
can be used to sense contact closures to ground. Each channel provides current
sinks for remote switching of external relays, such as the HP 33311 series
coaxial switches.
|
| |
| |
Cambell Scientific
|
DSP4
|
Cambell Scientific DSP4
|
$100.00
|
|
|
Cambell Scientific DSP4
The DSP4 is a real-time data display for use with Campbell Scientific dataloggers in vehicle testing applications.
The DSP4's low-profile packaging permits dashboard mounting in a variety of vehicles without obstructing the
driver's view. The DSP4 displays four measurements with user-defined labels and input ID numbers. Selection
of displayed measurements can be changed quickly with push-button switches.
Eight backlit, push-button switches allow display of status conditions and/or control of datalogger functions.
For example, the switches can be used to control conditional output or indicate programmed fault conditions.
The DSP4 is designed around a two-line by forty-character, vacuum fluorescent display functional over a wide
temperature range. The display is recessed in a black bezel to enhance readability in bright daylight.
Features
Specifications
10
20
30
40
50
60
70
80
90
10
20
30
40
50
60
70
80
90
LOGAN, UTAH
DSP4
DISPLAY
ON
OFF
DC HI
SELECT
CURSOR
UP
DOWN
MADE IN USA
FLAGS:
1
2
3
4
5
6
7
8
01 :Oil Temp
121.0
02 : CoolantT
64.7
03 :ENG_RPM
3540.
04 : Ambient
74.5
? Displays any four of the datalogger's 254 measurement
locations; nine-character labels can be
assigned to the first 99 locations
? Status/control of datalogger's user flags with pushbutton,
backlit switches
? Transfers datalogger programs and data to/from
SM4M/16M, SM192/716 Storage Modules or
CSM1 Card Storage Modules
? Memory protected during loss of DSP4 primary
power
Power requirements: 10.0 to 15.6 Vdc at 1 Amp.
Operating Temperature Range: -40° to +80°C
Dimensions: 2.9"H, 12.9"L, 3.3"D; Weight: 4 lbs.
Mounting: Single blind-threaded hole in each end
panel ¼" x 20, 0.31" depth.
The DSP4 is compatible with the following dataloggers:
- CR500/510
- CR10(X)
- 21X
- CR23X
- CR5000 (requires update to latest PROM)
- CR9000(C)
- CR7 (units built prior to 6/85 require a
6303 CPU card) |
| |
| |
Cambell Scientific
|
CR21
|
Campbell Scientific CR21 Micrologger
|
Contact Sales
|
|
|
Campbell Scientific CR21 Micrologger
Campbell Scientific CR21 Micrologger
The CR21 featured an integrated design with built-in power supply,
keyboard, and display. It looks very similar to, and is often confused with its
replacement, the 21X Micrologger. The CR21 stored up to 608 data points in
internal memory. A typical field-based CR21 consists of a CR21 or CR21L
Micrologger with a CR21 Instruction Set (PROMs).
Features
- Replaced by the 21X Micrologger® (now retired), CR23X Micrologger®
- Manufactured from 1979-1985
- Self-contained datalogger with built-in keyboard and power supply
- Specialized sensors required; some no longer available
- Stored 608 data points in internal memory (volatile)
- ASCII data format
- Some repairs no longer available
Specifications
- Seven single-ended analog inputs (-0.2 to +2.5 Vdc or
-2 mV to +25 mV, FSR)
- Two pulse count channels (150 Hz (CH 8) and 50 Hz (CH 9), maximum
input frequency)
- One 4 Vac excitation channel
- Three 2 Vdc sensor excitation channels
- Two binary inputs
- Four control outputs
- One 5 Vdc power terminal
- One 12 Vdc power terminal
- One a serial I/O port.
|
| |
| |
Cambell Scientific
|
SM64
|
Campbell Scientific SM64 Storage Module
|
Contact Sales
|
|
|
Campbell Scientific SM64 Storage Module
Campbell Scientific SM64 Storage Module
The Campbell Scientific SM64 Storage module is an external memory
module. Designed to work with the CR21 Datalogger.
|
| |
| |
Dranetz / BMI
|
TR2500
|
Dranetz/BMI TR2500 500 Amp Current Probe
|
Contact Sales
|
|
|
Dranetz/BMI TR2500 500 Amp Current Probe
Dranetz/BMI TR2500 500 Amp Current Probe
Rent me for $50 a month
for use with the Dranetz/BMI 4300 Power
Platform
These models will measure rms currents from 10 to 500 A. They
plug directly into any of the current inputs on the rear panel. These probes are
not recommended for measuring medium or high frequency transients.
Specifications
: 1 to 500 Arms
Accuracy: 48 to 400 Hz: ±1.5% reading ±0.6A 400 to
3000 Hz: ±3% reading ±0.8A
Working voltage: 600 V max.
Frequency range: 48 to 3000 Hz
Output signal: 3 mV/A
Maximum conductor size: 1.18" (30 mm)
Maximum bus bar size: 2.5 x 0.20" (63 x 5 mm)
Phase shift (45 to 1000 Hz): Less than 4º
Operating temperature: 14 to 122 ºF (-10 to 50 ºC)
Storage temperature: -40 to 158 ºF (-40 to 70 ºC)
Dimensions: 2.60 x 7.68 x 1.34? (66 x 195 x 34 mm)
Weight: 14.82 oz. (420 g)
NOTE Current probe TR2500 can be used interchangeably with
TR2500A.
|
| |
| |
Fluke
|
642496
|
Fluke 2280A 162 20 Channel Input Card
|
$100.00
|
|
|
Fluke 2280A 2280A/62 20 Channel Isothermal Input Card
Fluke 2280A 2280A/162 20 Channel Isothermal Input
Card
For the Fluke 2280A Series Dataloggers
Fluke 2280A/162 Isothermal input connector with 20 channels for
thermocouples, DC voltage, or DC current. This is used in conjunction with a
2280A Series input module. For use in a FLU-228x mainframe. 20-channels
with 3-pole dry reed relay per channel. Requires 2280A-175 or 2280A-176 input
module. Many in stock.
|
| |
| |
Fluke
|
642587
|
Fluke 2280A 175 20 Channel Input Module
|
$100.00
|
|
|
Fluke 2280A 2280A/175 20 Channel Isothermal Input Module
Fluke 2280A 2280A/175 20 Channel Isothermal Input
Module
For the Fluke 2280A Series Dataloggers
Fluke 2280A/175 Isothermal input connector with 20 channels for
thermocouples, DC voltage, or DC current. This is used in conjunction with a
2280A Series input card. For use in a FLU-228x mainframe. Many in stock.
|
| |
| |
Fluke
|
2286A
|
Fluke 2286A Data Logging System
|
$1,500.00
|
|
|
with system guide, user guide, programming forms, and lock-out key, with integrated printer 3.5 inch drive and Options: 161 hi performance A/D converter 211 math processor The Data Logger Environment One use of the Data Logger is to simultaneously monitor |
| |
| |
Fluke
|
2625A
|
Fluke 2625A Hydra Datalogger
|
$2,995.00
|
|
|
Fluke 2625A Hydra Datalogger
Rent me for $300 a month
The Hydra Series is available in three models to
fit many application requirements. The 2620A Hydra Data Acquisition Unit is a
compact front end for use with your PC. The portable 2625A Hydra Data Logger
features non-volatile memory that stores more than 2000 scans, for stand-alone
applications. And the 2635A Hydra Data Bucket with its removable memory card for
data and set-up storage is the most versatile model - ideal for remote
monitoring applications.
All models are easy to set up and reconfigure from
the front panel. Additionally, all units have bi-directional communication via
RS-232C, which enables control from a host computer. The RS-232C interface also
supports stand-alone use with a serial printer. An optional GPIB/IEEE-488
interface is available for the 2620A only.
The Hydra Series is extremely rugged and able to
operate in diverse environments. Its operating range is 0 to 60ºC, and it is
tested to stringent shock and vibration standards. Hydra's sturdy metal chassis
effectively shields against electromagnetic interference, maintaining high
measurement accuracy on low level signals. The analog circuitry is also isolated
from the digital circuitry so you can measure high voltages directly (up to 300V
ac rms). And it conforms to I.E.C., C.E. and CSA safety standards. What's more,
all set-up information is battery-backed, so it's immune to power failure. Hydra
will return from a power loss and resume scanning, while all configuration
information and stored data remain intact.
2625 Hydra Data Logger
- A low-cost alternative for stand-alone
monitoring operations.
- Internal memory
- A built-in nonvolatile memory that can store
more than 2000 scans.
- Flexible data retrieval
- The ability to upload stored data or transfer
real-time data via modem, or directly to your PC via the RS-232 port.
2625A Data Memory Specifications
2625A Data Storage Stores 2047 scans.
Scan Contents
- Memory life: 5 years minimum; at 25ºC
- Date and time stamp
- All defined analog input channel values
- Status of four alarm outputs and eight digital I/O Totalizer count
|
| |
| |
Fluke
|
2645A
|
Fluke 2645A Netdaq Networked Data Acquisition Unit
|
Contact Sales
|
|
|
Fluke 2645A Netdaq Networked Data Acquisition Unit Fluke 2645A Netdaq Networked Data Acquisition Unit Rent me for $500 a month
NetDAQ Data Acquisition Units give you a powerful combination of hardware and software that's ideal for small-to-medium scale process monitoring and test systems. They answer the escalating need for measurement, recording, and analysis tools that enable you to improve quality, maximize process efficiency and meet regulatory requirements. Building blocks of 20 channels can be expanded into integrated systems of up to 400 channels. Choose between two models for speed up to 1000 rps and accuracy up to 0.01%. All NetDAQs utilize Fluke's patented Universal Input Module which accepts any combination of analog input types for each of its 20 channels - without the need for external signal conditioning. Simply pre-wire the Universal Input Module to directly measure temperature, dc volts, ac volts, resistance, 4-20 mA, and frequency. (For more information refer to the Universal Input Module in this section.) Distributed NetDAQ systems plug right into your existing networks to send data directly to a PC. This saves the cost of setting a new network and allows multiple users to simultaneously view data in real time. A NetDAQ unit can also be used as a portable dedicated system connected to a notebook computer for maintenance, product validation, research, and troubleshooting applications. Features - Data Acquisition, Up to 1,000 Readings Per Second
- 20 Analog Input Channels Expandable Up to 400 Channels
- Extensive Optional Plotting and Trending Capabilities
- Optional Wall, Cabinet, or Rack Mounting
- May Be Connected to Ethernet Networks
- Replaces Chart Recorders
System Configuration Set up your NetDAQ system the way you want it. You can set up your NetDAQ system in several different ways. Configure an isolated system, daisy-chaining as many as 20 NetDAQ units to your PC with a high-speed communication line. This is a quick, simple way to send real time data directly to a PC. Or, add NetDAQ units directly to your company's network. Sharing the network cabling and hardware that's already installed saves you time and expense. And, if you wish, all the users on your network have an easy way to access the data you're collecting. The Universal Input Module makes configuration a snap NetDAQ's Universal Input Module lets you easily measure just about any electrical or physical parameter without changing hardware or adding external signal conditioning. Any combination of dc voltage, ac voltage, thermocouples, current, RTD, resistance (2- or 4-wire), or frequency measurement can be connected directly to the input module. Fluke's proprietary signal conditioning capability is built directly into the NetDAQ unit, thus eliminating the need to purchase external conditioning modules. |
| |
| |
Fluke
|
2635A Hydra
|
Fluke Hydra 2635A Portable Data Acquisition System
|
$3,499.00
|
|
|
New Page 1
Fluke Hydra 2635A Portable Data Acquisition
System
Rent me for $350 a month
2635A Hydra Data
Bucket
The ideal choice for gathering and transporting
large volumes of data and for working extended periods from remote locations.
The Hydra Series offers easy portability along with Fluke's built-in signal
conditioning and Universal Input Module at a price to fit your budget. You can
easily retrieve data from the Hydra units via the RS-232 interface, or through a
modem in upload or real-time mode.
Flexibility
The Hydra Data Bucket comes equipped with a 256 KB
PCMCIA card and is also available with either a 1 MB, 2 MB, or 4 MB memory card
to suit your data storage needs. Data may be uploaded from these cards via the
Hydra RS-232 port, the optional 263XA-803 memory card drive, or from your
computer's standard PCMCIA slot. Real-time data can be simultaneously
transferred to a PC at the same time it is recorded to the memory card.
Quick setups
Simply push a few front panel buttons or load
instrument setups from the memory card.
Fail-safe features
The Hydra Data Bucket gives advance indication of
a low battery or low memory condition on the memory card. Its internal memory
buffer continues to store up to 70 scans while the card is removed.
Universal Input Module
The removable Universal Input Module enables fast,
convenient set-up and reconfiguration. Any combination of dc voltage, ac
voltage, thermocouple, RTD, resistance, or frequency measurements can be
connected to the input module without the need for additional signal
conditioning. Thermocouple reference junction compensation is automatically
performed by sensing the temperature of the input module's isothermal block. For
applications with multiple measurement locations, purchasing additional input
modules provides the ability to quickly connect and disconnect a Hydra to these
various sites while leaving all sensor wiring intact.
Portable Operation
The 2635A Hydra Data Bucket has been designed for
applications where data is gathered in a stand-alone manner "on
location" and later uploaded to a PC for analysis and/or archiving. Three
models of the Hydra Data Bucket are available with PC memory cards ranging in
size from 256K, 1 Mb, 2Mb and 4Mb in size. Up to 450,000 readings may be stored
on a 2M byte memory card. For applications where large amounts of data are
generated, you may swap memory cards without interrupting the Data Bucket's
scanning.
|
| |
| |
Fluke
|
Hydra Software
|
Fluke Hydra Logger for Windows Software
|
$499.00
|
|
|
New Page 1
Fluke Hydra Logger for Windows Software
Hydra Logger for Windows
The Hydra Logger for Windows software package
gives you a powerful data acquisition system when combined with a Hydra
instrument and your PC. Hydra Logger gives you control of Hydra's powerful
functions, including scanning, signal conditioning, sensor linearization, alarm
detection and reporting, non-volatile data memory, advanced trend plotting and
more. "Logger" supports the 2625A and 2635A Hydra models. With Hydra
Logger's optional, trend plotting package, Trend Link for Fluke, you can control
how your data is displayed. You can quickly scroll through real time and
historical data, or view data from all channels simultaneously, on a single
screen. Or, you can plot one or multiple channels in real time, even
superimposing channels on other channels. Zoom in and out features, and
statistics make this optional package ideal for report and analysis needs.
Hydra LabVIEW Driver
The Hydra
LabVIEW driver is available from this site for LabVIEW 4.0 or later. LabVIEW
is available from National Instruments.
|
| |
| |
Fluke
|
2620A Hydra
|
Fluke Model 2620A Hydra Datalogger
|
$1,750.00
|
|
|
Fluke Model 2620A Hydra Datalogger
Fluke Model 2620A Hydra Datalogger
Rent me for $250 a month
Fluke 2620A Hydra
Data Acquisition Unit
Hydra is ideal for applications that require direct connection to a PC for
real-time data collection. The Hydra Series offers
easy portability along with Fluke's built-in signal conditioning and Universal
Input Module, at a price to fit your budget. You can easily retrieve data from
the Hydra units via the RS-232 interface, or through a modem in upload or
real-time mode. Channel information and measurement parameters can be set up
directly from the front panel or your PC. Three models featuring removable
memory card data storage, internal memory storage, and direct real-time data
transfer options. Should power fail, these instruments automatically resume data
collection when power is restored.
Easy-to-use front-end
An RS-232 serial interface makes it easy to connect the Hydra Data
Acquisition Unit to a PC or modem for real-time data acquisition. The 2620A
can also be used as a 20-channel panel meter.
IEEE interface
An IEEE-488 interface easily allows you to integrate the 2620A with other
IEEE-488 instruments and your PC. The 2620A delivers workhorse performance for
a wide variety of applications such as test and monitoring systems.
Universal
Input Module
The removable Universal Input Module enables fast, convenient set-up and
reconfiguration. Any combination of dc voltage, ac voltage, thermocouple, RTD,
resistance, or frequency measurements can be connected to the input module
without the need for additional signal conditioning. Thermocouple reference
junction compensation is automatically performed by sensing the temperature of
the input module's isothermal block. For applications with multiple
measurement locations, purchasing additional input modules provides the
ability to quickly connect and disconnect a Hydra to these various sites while
leaving all sensor wiring intact.
Software
Hydra Logger
The Hydra Logger software package is included with each Hydra unit. It
gives you a powerful windows-based data acquisition system when combined
with a Hydra instrument and your PC. Hydra Logger gives you control of
Hydra's powerful functions, including scanning, signal conditioning, sensor
linearization, alarm detection and reporting, non-volatile data memory,
advanced trend plotting and more.
Trend Link for Fluke
With Hydra Logger's optional, trend plotting package, Trend Link for
Fluke, you can control how your data is displayed. You can quickly scroll
through real time and historical data, or view data from all channels
simultaneously, on a single screen. Or, you can plot one or multiple
channels in real time, even superimposing channels on other channels. Zoom
in and out features, and statistics make this optional package ideal for
report and analysis needs.
|
| |
| |
Fluke
|
Trend Link Software
|
Fluke Trend Link Software
|
Contact Sales
|
|
|
Fluke Trend Link Software
for
the Hydra Series Dataloggers
Trend Link is a comprehensive trend plotting and analysis
package that plots data graphically in real time. Trend Link allows you
to quickly scroll through real time and historical data, view data from
all channels simultaneously, compare real time data to an historical
template in batch mode, and superimpose selected channels for closer
analysis. Any portion of a trend may be examined more closely by
utilizing Trend Link?s Zoom function.
Trend Link for Fluke software enables you to easily access, view,
analyze and compare tremendous amounts of real time or historical data
from any Fluke data acquisition product, making paper chart recorders
obsolete. Trend Link is designed to make it easy to zoom in on data,
review and compare historical data to real-time data, compare batch
processing operations, and automatically view statistics on any channel.
|
| |
| |
Reed
|
8829 Kit
|
New Reed 8829 Low Cost Temperature and Humidity Datalogger
|
$165.00
|
|
|
New Reed 8829 Low Cost Temperature and Humidity Datalogger
New Reed 8829 Low Cost Temperature and
Humidity Datalogger
The Reed is an ultra compact data logger that records the temperature
and humidity readings for days,
weeks, even months. Look at the incredibly low cost. If you need a low cost
solution you can not beat this. This cost includes the required Reed 8818
communications kit with software and cables required for operation
? °F or °C selectable
? LCD display
? Logs data for days,
weeks or months
? Programmable
sampling rate from
1 second to 2 hours
? Three start modes:
scheduled,
immediate or magnetic
? Records up to 16,000
readings
? Real-time clock
stores data and time
? Data is retained in
non-volatile
memory
? User-defined min/max
alarm settings
? Program by RS-232
serial port and
Windows® compatible software
? 60? cable with DB9
connector
? Optional data logger
kit (includes docking station, RS-232 cable and Windows® compatible software) and battery
operated
printer available
Humidity Range: 0
to 100% RH
Temperature Range:
32 to 185° F
(0 to 85°C)
Temperature Range:
-40 to 185°F (-40 to 85°C)
|
| |
| |
Reed
|
C-342/345
|
New Reed C-342/345 Temperature/Humidity Data Logger
|
$195.00
|
|
|
New Reed C-342/345 Temperature/Humidity Data Logger
New Reed C-342/345 Temperature/Humidity Data
Logger
Easy to use data logger records up to 64,000 temperature and
humidity readings.
-
°F or °C selectable
-
LCD display with LED backlight
-
32,000 records per channel
-
Real-time clock stores data and time
-
Memory status and battery status displays
-
Program by ?Slim-Com? RS-232 interface and Windows®
compatible software
-
Shipped with wall hanging tag
-
Includes model 345 communication base
-
Temperature Range:
-22
to 158°F (-30 to 70°C)
Resolution: 0.1°F
(0.1°C)
Accuracy: ±0.7°C
Humidity Range: 5 to
98% RH
Resolution: 0.1% RH
Accuracy: ±3% RH
Power Supply: 2 x 1.5V
AAA batteries
Dimensions: 92 x 55 x
22mm
|
| |
| |
Reed
|
THR-1
|
New Reed THR-1 7 Day Temperature and Humidity Recorder
|
$525.00
|
|
|
New Reed THR-1 7 Day Temperature and Humidity Recorder
New Reed THR-1 7 Day Temperature and Humidity
Recorder
Simultaneously records ambient temperature and relative humidity
conditions on paper charts. Ideal for situations requiring hard copy
documentation of temperature and humidity such as laboratories, hospitals,
museums, art exhibits and nuclear facilities
-
Choice of 1-day or 7-day models
-
Bi-mettalic coil temperature sensor and de-fatted hair
humidity sensor
-
Provides maximum and minimum values
-
Humidity Range: 30 to 100% RH
-
Resolution: 1-day: 1% RH/15 min.; 7-day: 1% RH/1 hour
-
Accuracy: 1-day: ±5% RH/5 min.; 7-day: ±5% RH/30 min.
-
Temperature Range: -15 to 40°C
-
Resolution: 1-day: 1°C/15 min.; 7-day: 1°C/1 hour
-
Accuracy: 1-day: ±1°C/5 min.; 7-day: ±1°C/30 min.
|
| |
| |
Reed
|
THR-2
|
New Reed THR-2 7 Day Temperature and Humidity Recorder
|
$525.00
|
|
|
New Reed THR-2 7 Day Temperature and Humidity Recorder
New Reed THR-2 1 Day Temperature and Humidity
Recorder
Simultaneously records ambient temperature and relative humidity
conditions on paper charts. Ideal for situations requiring hard copy
documentation of temperature and humidity such as laboratories, hospitals,
museums, art exhibits and nuclear facilities
-
Choice of 1-day or 7-day models
-
Bi-mettalic coil temperature sensor and de-fatted hair
humidity sensor
-
Provides maximum and minimum values
-
Humidity Range: 30 to 100% RH
-
Resolution: 1-day: 1% RH/15 min.; 7-day: 1% RH/1 hour
-
Accuracy: 1-day: ±5% RH/5 min.; 7-day: ±5% RH/30 min.
-
Temperature Range: -15 to 40°C
-
Resolution: 1-day: 1°C/15 min.; 7-day: 1°C/1 hour
-
Accuracy: 1-day: ±1°C/5 min.; 7-day: ±1°C/30 min.
|
| |
| |
Sony Data Recorders
|
PCCK21
|
Sony PCCK21 Synchronization Cable
|
$199.00
|
|
|
New Page 1
Sony PCCK21 Synchronization Cable
Synchronization cable for the SIR
series data recorders. Allows multiple units to be synchronized together.
|
| |
| |
Sony Data Recorders
|
PCIF-200A
|
Sony PCIF-200A Computer Interface
|
Contact Sales
|
|
|
New Page 2
Sony PCIF-200A Computer Interface
The Sony PCIF-200A is a high
speed interface that converts your Sony PCxxx series data recorders into an
extremely high speed data acquisition system. The storage is only limited by the
size of the available hard drive. This allows the benefit of direct transfer of
with the accuracy of the Sony front end. This is a kit including software,
connecting boards and cables.
|
| |
| |
Sony Data Recorders
|
PCRM21AX
|
Sony PCRM21AX Remote Control
|
$495.00
|
|
|
New Page 1
Sony PCRM21AX Remote Control
External Remote Control for the
SIR series data recorders. Allows remote operation and includes data input level
monitoring.
Features
- Display: Bar graph(up
to 8ch)
- Tape position data
- Alarm display
- Control: REC, STOP,
FWD, FF, REW, PAUSE, search, ID increment, counter reset Interface
- RS-232C Cable length:
3 m (9' 10")
- Dimensions:
210(W)x25(H)x70(D) mm [8.3"x1.01"x 2.8")excluding projections
- Weight: Approx. 0.5kg
(1.1 lbs)
|
| |
| |
Sony Data Recorders
|
SIR-1000
|
Sony SIR-1000 16 Channel Data Recorder
|
Contact Sales
|
|
|
Sony SIR-1000 16 Channel Data Recorder
Sony SIR-1000 16 Channel Data Recorder Rent me for $1000 a month
The Sony SIR-1000 is a high speed digital data
recorders that utilise AIT (Advanced Intelligent Tape) technology. It is a
16-channel, high-speed digital data recorder suitable for data recording in the
field or laboratory. Frequency Response is from DC to 20 kHz for 16 or 32
channels (see SCX-32 for 16-channel expansion). 2 to 32 hour recording and
playback with variable tape speeds. Over 80 dB dynamic range; 16-bit linear
quantization. Equipped with BNC single-ended analog input connectors. Data can
be stored, downloaded to a PC or replayed in real-time. High quality data
recordings from the best in the industry.
Features
-
AIT Media - 25GB and 2-32 hours recording duration per tape
-
Input ranges from ±0.1V to ±20V. (ICP® facility SIR-1000i)
-
Bandwidths up to 20kHz on a maximum of 32 channels using a
Channel Expansion Unit
-
16-128 Channels (20kHz - 5kHz)
-
90-250VAC, 9-32VDC and Battery Powered
-
>80dB Dynamic Range
-
Lightweight and Portable
|
| |
| |
TEAC
|
RD-101T
|
Teac RD-101T 4 Channel PCM Data Recorder
|
Contact Sales
|
|
|
Teac RD-101T 4 Channel PCM Data Recorder Teac RD-101T 4 Channel PCM Data Recorder Rent me for $300 a month With option - TZ-313FA Anti aliasing Filter
- Uses Standard DAT Tapes
Features: High-quality data (accuracy) - The quadruple oversampling digital filter is used as the output stage in the multiplex PCM recording method. The signal-to-noise ratio is 70 dB.
The frequency characteristic flatness is +0.5 dB, -1 dB. The phase difference between channels is 5° (fmax).
Multi-channels and wide band - The RD-101T uses a 2-channel/4-channel switching system. The band for 2-channel recording is 20 kHz and the band for 4-channel recording is 10 kHz.
Small and compact - The data recorder is approximately 306 mm wide x 100 mm high x 307 mm deep, and weighs approximately seven kilograms. The data recorder is therefore very portable.
Long recording time - When a 120 tape (approximately 60 m) is used, data can be recorded continuously for two hours.
Three power supplies - Operates on either AC input of 90-130 (180-250) volts, DC input of 11-30 volts, which are provided normally, and an optional rechargeable battery unit. The battery unit can be incorporated by mounting it on the data recorder. Since the battery charge function is built into the data recorder and protection for battery over-discharging is provided, the RD-101T can be used both indoors and outdoors.
Easy operation (condition setting is unnecessary) - The input range is fixed to eliminate the need for complicated range setting. The purpose of this function is to approach the absolute value recording by making the input and output voltages equal:
Memo sound channel - In addition to the data channels, a channel used only for voice recording and reproduction is provided. Since the microphone built into the data recorder is provided normally for recording, environmental sounds can always be recorded during measurement.
Time code recording channel - In addition to the data channels, a channel used only for recording and reproduction of time codes is built in. The year, month, day, hours, minutes, and seconds of the built-in clock with perpetual calendar are automatically recorded. Since the time code is always automatically recorded, it can be used to confirm the recording time of measurement data on the display.
Data number (ID number) recording channel - In addition to the data channels, a channel used only for recording and reproduction of ID numbers is built in. The ID number of the recorded data is automatically recorded. The ID number is incremented by one each time recording starts or the EVENT button is pressed.
High-speed search - The recorded ID number can be searched for at high speed during reproduction. The search is performed both in the forward and reverse directions. When the target ID number is found, the target data is reproduced from the beginning.
Pressing the PAUSE button during search causes the tape to pause at the beginning of the data when the search ends.
|
| |
|
Test Equipment, test eqipment, test and measurement, US INSTRUMENT SERVICES, rental, sales, used, HP, Hewlett Packard, Tektronix, tektronics, TEK, CSI, Campbell, oscilloscopes, ossiliscopes, optical, fiberoptic, Telecom, test sets, network, logic, B&K, Bruel, Kjaer, Dranetz, Telecom, TTC, Wandel, Goltermann, spectrum analyzers, logic analyzers, digital, multimeters, counters, data acquisition, HiPot, meggers, ground testing, protocol, pirateracing, butch
|
©1999-2002 [fill in company name] All Rights Reserved |
contact
webmaster
| powered by
corezon
|
|
All logos and trademarks are properties of their respective companies. Product price,
specification, warranty and availability subject to change without notice.
|
|
|