Mfg. Name Mfg. Part# Product Unit Price Add To Cart
 
Agilent / HP 53131A Agilent 53131A 225 Mhz Universal Frequency Counter Contact Sales

Agilent 53131A Universal Frequency Counter 10 digit

Rent me for $150 a month

Sales price varies with installed options

The Agilent 53131A universal counter has the capability to do the job quickly and correctly from fast signal processing to automated limit tests. The Agilent 53131A has frequency resolution of 10 digits per second, 500 ps time interval resolution and a complete set of test and analysis features. The unit comes with two 225 MHz channels, and you can choose an optional third channel that measures up to 3 GHz, 5 GHz, or 12.4 GHz.

Features
  • Measurements include frequency, frequency ratio, time interval, rise/fall time, phase, duty cycle, positive/negative pulse width, totalize, peak voltage, time interval average and time interval delay
  • Automated limit tests and one-button measurement setups for fast, easy operation
  • Two 225 MHz input channels, plus optional third channel up to 12.4 GHz
  • Built-in statistics feature lets you simultaneously measure average, min/max, and standard deviation
  • 10 digits per second, 500 ps time interval resolution

Other Options
Opt. 001 Medium-stability timebase
Opt. 010 High-stability timebase
Opt. 012 Ultra-High stability timebase (53132A only)
Opt. 015 1.5 GHz RF input Ch 2 for 53181A only
Opt. 030 3 GHz RF input Ch 3 (Ch 2 on 53181A )
Opt. 050 5 GHz RF input with type N connector Ch 3 (Ch 2 on 53181A)
Opt. 124 12.4 GHz RF input with type N connector Ch 3 (Ch 2 on 53181A)
Opt. 060 Rear-panel connectors
 
Agilent / HP 53131A Agilent 53131A 3Ghz Universal Frequency Counter $2,650.00

Agilent 53131A Universal Frequency Counter 10 digit

3 Ghz option


Rent me for $150 a month

Sales price varies with installed options

The Agilent 53131A universal counter has the capability to do the job quickly and correctly from fast signal processing to automated limit tests. The Agilent 53131A has frequency resolution of 10 digits per second, 500 ps time interval resolution and a complete set of test and analysis features. The unit comes with two 225 MHz channels, and you can choose an optional third channel that measures up to 3 GHz, 5 GHz, or 12.4 GHz.

Features
  • Measurements include frequency, frequency ratio, time interval, rise/fall time, phase, duty cycle, positive/negative pulse width, totalize, peak voltage, time interval average and time interval delay
  • Automated limit tests and one-button measurement setups for fast, easy operation
  • Two 225 MHz input channels, plus optional third channel up to 12.4 GHz
  • Built-in statistics feature lets you simultaneously measure average, min/max, and standard deviation
  • 10 digits per second, 500 ps time interval resolution

Other Options
Opt. 001 Medium-stability timebase
Opt. 010 High-stability timebase
Opt. 012 Ultra-High stability timebase (53132A only)
Opt. 015 1.5 GHz RF input Ch 2 for 53181A only
Opt. 030 3 GHz RF input Ch 3 (Ch 2 on 53181A )
Opt. 050 5 GHz RF input with type N connector Ch 3 (Ch 2 on 53181A)
Opt. 124 12.4 GHz RF input with type N connector Ch 3 (Ch 2 on 53181A)
Opt. 060 Rear-panel connectors
 
Agilent / HP 53131A Agilent 53181A Universal Frequency Counter Contact Sales

Agilent 53181A Universal Frequency Counter 10 digit

Rent me for $150 a month

Sales price varies with installed options


The Agilent 53181A RF counter provides fast, precise results with the core measurements needed for RF tests. It provides the same signal processing and test automation features as the Agilent 53131A and Agilent 53132A universal counters, along with 10 digits/second resolution. The Agilent 53181A offers a single 225 MHz channel standard, and you can choose an optional second channel that measures up to 1.5 GHz, 3 GHz, 5 GHz or 12.4 GHz.

Features

  • Measurements include frequency, frequency ratio (with optional channel 2), period and peak voltage
  • Automated limit tests and one-button measurement setups for fast, easy operation
  • 10 digits/second resolution
  • Built-in statistics feature lets you simultaneously measure average, min/max, and standard deviation
  • One 225 MHz input channel, plus optional second channel up to 12.4 GHz

Other Options
Opt. 001 Medium-stability timebase
Opt. 010 High-stability timebase
Opt. 012 Ultra-High stability timebase (53132A only)
Opt. 015 1.5 GHz RF input Ch 2 for 53181A only
Opt. 030 3 GHz RF input Ch 3 (Ch 2 on 53181A )
Opt. 050 5 GHz RF input with type N connector Ch 3 (Ch 2 on 53181A)
Opt. 124 12.4 GHz RF input with type N connector Ch 3 (Ch 2 on 53181A)
Opt. 060 Rear-panel connectors
 
Agilent / HP 5334A Agilent 5334A Frequency Counter $249.00

Agilent 5334A Dual Channel Frequency Counter

The HP 5334A is a two-channel, 100 MHz Universal Counter with 9 digits in 1 sec. and 2 nS single shot time interval resolution

  • 2 matched 100 MHz channels
  • 9 digits per second resolution
  • automatic rise / fall time, pulse width, and peak amplitude measurements
  • 10 memories for setup
  • HPIB interface

Agilent 5334A Performance Characteristics

Number of Channels 2 ch
Minimum Frequency, Ch. 1 0.001 Hz
Maximum Frequency, Ch. 1 100 MHz
Sensitivity, Channel 1 35 mV
Input Impedance, Ch.1 1 MOhm
Input Attenuation, Ch 1 x1,x10
Input Coupling, Ch 1 AC,DC
Minimum Frequency, Ch. 2 0.001 Hz
Maximum Frequency, Ch. 2 100 MHz
Sensitivity, Channel 2 75 mV
Input Impedance, Ch. 2 1 MOhm
Input Attenuation, Ch 2 x1,x10
Input Coupling, Ch 2 AC,DC
Time base stability .0000003 /mo
Trigger Source Internal
Measurement Throughput 0.007143 s
External Time base reference 10 MHz


 
Agilent / HP 5350B Agilent 5350B 20 Ghz Counter $1,995.00

Agilent 5350B 20 GHz CW Microwave Counter

 The Agilent 5350B provides fast and precise measurements from 10 Hz to 20 GHz and features microwave components that are integrated on a single hybrid gallium arsenide (GaAs) circuit for added speed and reliability. The 5350B distinguished by wide frequency coverage, exceptional sensitivity, fast tracking, high measurement throughput, and wide FM tolerance. Built-in microprocessors provide math functions, including measurement scaling and offset. Automatic amplitude discrimination measures the frequency of the highest-amplitude signal in a multi-signal environment. A full set of diagnostic routines provides general information and troubleshooting. The 5350B integrates easily into test systems. English-like commands simplify integration with other components, and the easy-to-read liquid crystal displays can serve as message centers for the system. Features Frequency range from 10 Hz to 20 GHz; directly measures without expensive mixers. Sensitivity to -40 dBm ensures accurate measurement of low-energy signals. Low kickback noise for sensitive environments; sleep mode reduces noise to -70 dBm. Fast acquisition time (60 ms in automatic, fast acquisition tracking mode; 20 ms in manual mode) for improved throughput. Up to 120 measurements per second (100 in automatic mode) over HP-IB (fully programmable). Fast tracking speed allows effortless tracking of source drift to 1 GHz per second; ideal for measuring the response of voltage-controlled oscillator to voltage-source tuning..
 
Agilent / HP 5383A Agilent 5383A 520Mhz Frequency Counter $299.00

Agilent 5383A 520 Mhz Frequency Counter

The 5383A 520 MHz Frequency Counter is designed to deliver reliable, high quality operation and covers the frequency range from 10Hz to 520MHz. Sensitivity of 25 mV rms (from 20Hz to 10MHz); 50 mV rms (from 10Hz to 50MHz). Input impedance is selectable: 1 Mohm, 40 pF or 50-ohms. Resolution direct count: 1Hz in 1 sec. Features 9-digit LED display.

 
Agilent / HP 5385A Agilent 5385A 1 Ghz Counter $595.00
Agilent 5385A Frequency Counter The Agilent 5385A Frequency Counter utilizes interpolar-enhanced reciprocal counting to provide outstanding performance at a low cost. Frequency coverage allows measurements from 10 Hz to 1 GHz, with resolution of 9 digits per second. The 5385A incorporates a programmable alphanumeric display, accessible remotely via either HP-IB (standard) or HP-IL (optional). The liquid crystal display (LCD) reduces component count, is easy to read (indoors or out), and improves counter reliability and serviceability. The half-rack width 5385A instrument is portable, rackable, and stackable for use in the field, at a workbench, or as part of an ATE system. Options include a four-hour-capacity battery pack, and a high-stability ovenized oscillator for higher accuracy. Features High input sensitivity extends applications Extensive input conditioning improves accuracy Variable display digits improve readability External DC operation extends portability Standard TCXO timebase Proven reliability High Input Sensitivity Sensitivity of at least 15 mV rms reduces the need for preamps, and improves low level signal measurement accuracy. Extensive Input Conditioning A low pass filter, automatic or manual attenuator and trigger level control features provide versatile signal-to-noise conditioning for optimum accuracy. Variable Display Digits View only readable digits from stable signals by controlling the number of display digits. Use as few as 3 or as many as 11 digits. External DC Operation Wide range (9-15V) external DC input power allows use of sources such as 12V automobile power to keep the timebase warm, or charge the battery option while in transit to remote sites.
 
Agilent / HP 53132A Agilent/HP 53132A 12 Digit Universal Frequency Counter Contact Sales
Agilent/HP 53132A 12 Digit Universal Frequency Counter

 

Agilent/HP 53132A 12 Digit Universal Frequency Counter

Rent me for $150 a month

Many options are available for this unit. Price will vary with installed options

 

The Agilent 53132A universal counter has frequency resolution of 12 digits per second, 150 ps time interval resolution and a complete set of test and analysis features. The unit comes with two 225 MHz channels, and you can choose an optional third channel that measures up to 3 GHz, 5 GHz or 12.4 GHz. Need a higher performance universal counter? From fast signal processing to automated limit tests, the Agilent 53132A has the tools to do the job quickly and correctly.

PC Connectivity Software

IntuiLink, free PC connectivity software allows you to easily transfer measurement data and images into familiar PC applications like Microsoft Office Excel and Word, with little or no programming. Use the following link for additional information and downloading instructions.

Features
  • Measurements include frequency, frequency ratio, time interval, rise/fall time, phase, duty cycle, positive/negative pulse width, totalize, peak voltage, time interval average and time interval delay
  • Automated limit tests and one-button measurement setups for fast, easy operation
  • Two 225 MHz input channels, plus optional third channel up to 12.4 GHz
  • Built-in statistics feature lets you simultaneously measure average, min/max, and standard deviation
  • 12 digits per second, 150 ps time interval resolution
  • GPIB is standard, USB is optional

Basic Options

  • Opt. 001 Medium-stability timebase
  • Opt. 010 High-stability timebase
  • Opt. 012 Ultra-high stability timebase (53132A only)
  • Opt. 015 1.5 GHz RF input Ch 2 for 53181A only
  • Opt. 030 3 GHz RF input Ch 3 (Ch 2 on 53181A )
  • Opt. 050 5 GHz RF input with type N connector Ch 3 (Ch 2 on 53181A)
  • Opt. 124 12.4 GHz RF input with type N connector Ch 3 (Ch 2 on 53181A)
  • Opt. 060 Rear-panel connectors
 
Agilent / HP 5316B Agilent/HP 5316B Dual 100 Mhz Counter $495.00
Agilent/HP 5316B Universal Counter

 

Agilent/HP 5316B Universal Counter

Rent me for $100 a month

The Agilent 5316B is a low-cost, high-performance universal counter offering frequency, period, time interval, ratio, and totalize measurements. Unique counting circuitry delivers the best of both reciprocal and conventional frequency counting. Programmable functions include all measurement modes, plus trigger level and trigger slope controls.

The 5316B is encased in high-quality metal that meets strict standards for electromagnetic compatibility, making it suited to applications such as low-level receiver or high-power transmitter testing. With standard HP-IB interfacing, 5316B is suited for ATE system design or other environments where interference from other equipment is a concern.

An optional 1-GHz C channel extends the frequency range for navigations and communications applications. A high-stability oven oscillator can also be added for higher accuracy in demanding environments.

Features

  • Exceptional resolution at both low and high frequencies
  • Three time-interval modes solve more problems
  • Flexible signal conditioning optimized for both frequency and time-interval measurements
  • Selectable gate time from 60 ms to 10 s
  • 100 MHz A and B input channels, Optional 1 GHz C channel
  • Full frequency range (to 100 MHz) on both input channels
  • Proven reliability and excellent RFI protection
  • Exceptional Resolution
  • Below 10 MHz, the counter measures the input signal period, then computes and displays the reciprocal frequency with 7 digits of resolution in one second for signals as low as 0.1 Hz. Above 10 MHz, the counter automatically performs as a conventional counter.
  • Three Modes
  • The HP 5316B offers 100 ns single-shot time-interval resolution. Time-interval averaging boosts performance to 10 ps resolution. A time-interval delay ignores spurious signals that would normally cause the counter to trigger.
  • Flexible Conditioning
  • Choose ac or dc coupling, a sensitivity control (variable attenuator), and a switchable low-pass filter. Both channels have trigger level controls with easy setting.
 
Agilent / HP 5334B Agilent/HP 5334B 100 Mhz 2 Channel Frequency Counter Contact Sales
Agilent/HP 5334B 100 Mhz 2 Channel Frequency Counter

 

Agilent/HP 5334B 100 Mhz 2 Channel Frequency Counter

 

   The Agilent 5334B counter offers high-resolution measurement power with versatile signal conditioning, triggering, and external arming features to handle a range of demanding measurement applications. Rise and fall time, pulse width, and AC/DC voltage can be measured at the push of a button or with a single HP-IB command. Automatic trigger level and attenuator settings provide adjustment-free measurements that are displayed in units of your choice.

This product has been replaced by the Agilent 53131A and 53132A counters.

 

Features

  • 200 ps time interval average resolution, 2 ns single-shot resolution
  • Selectable resolution and measurement time
  • Full complement of measurements
  • External arming increases measurement capability
  • Two matched 100 MHz A and B input channels (optional 1.3 GHz C channel)
  • Independent selection of signal conditioning for both A and B channels
  • Proven reliability and excellent RFI protection

 

 
Agilent / HP 5335A Agilent/HP 5335A 200 MHz Dual Channel Counter $695.00
New Page 1

 

Agilent/HP 5335A 200 MHz Dual Channel Counter

Rent me for $150 a month

The Agilent/HP 5335A counter offers high-resolution measurement power, standard GPIB interfacing, and many features for user convenience. Manual or automatic triggering allows you to set triggers, or have the 5335A set them for you. With the press of a button, perform a variety of measurements and display A and B channel trigger levels and gate time. Built-in statistical characterization and mathematical functions offer better understanding of measured parameters.

A variety of options increase the performance and functionality of the 5335A. A 1.3 GHz C channel extends the frequency range for navigations and communications applications. A high-stability oven oscillator can be added for higher accuracy in demanding environments, and an add-on DC digital voltmeter lets you perform DC voltage measurements. 

Agilent/HP 5335A Counter Specifications

  • Selectable resolution and measurement time
  • Full complement of measurements, math and statistics functions
  • External arming increases measurement capability
  • Full function ratio measurements
  • 100 ps time interval average resolution, 2 ns single-shot resolution
  • 200 MHz (Channel A) and 100 MHz (Channel B) input channels
  • Proven reliability and excellent RFI protection

 

 
Agilent / HP 5347A Agilent/HP 5347A 20 Ghz Counter/Power Meter Contact Sales

 

Agilent/HP 5347A 20 Ghz Counter/Power Meter

Rent me for $150 a month

 

The Agilent 5347A 20 GHz Microwave Counter/Power Meter offers the convenience of a single instrument that makes frequency and power measurements with accuracy and resolution comparable to stand-alone instruments. As a true power meter, the Agilent 5347A offers excellent dynamic range, linearity, and accuracy. It uses the same proven power sensors as HP's standalone power meters. The high-performance frequency counter measures frequency from 10 Hz to 20 GHz.

With only five function keys, the Agilent 5347A is especially easy to use. Its rugged, lightweight package, along with an optional internal battery that provides up to two hours of cordless measurements, makes the Agilent 5347A ideal for taking portable measurements.

Features

  • True power meter performance
  • Negligible power meter error
  • Outstanding frequency measurements
  • Built-in sensor calibration tables save time
  • External DC operation for greater measurement flexibility
  • Supports three HP power sensors

 

Product Specifications for Input 1

  • Frequency Range: 500 MHz to 20 GHz 

  • Sensitivity 500 MHz - 12.4 GHz: -32 dBm, 12.4 GHz - 20.0 GHz: -27 dBm

  • Resolution: 1 Hz or 10 kHz, selectable

Input 2

  • Frequency Range: 10 Hz - 525 MHz

  • Sensitivity: 25 mV rms 

  • Impedance: 1 Mohm nominal or 50 ohm nominal

  • Accuracy: ±1 LSD ±[(1.4 x Trigger Error/Gate Time)±Time Base Error] x frequency

  • Resolution: 1 Hz or 10 kHz, selectable

  • AM Tolerance: Any modulation index provided the minimum signal level is not less than the sensitivity specification.

Power Meter

  • Frequency Range: 0 MHz to 20 GHz, sensor dependent Power Range: -70 dBm to +20 dBm (100 pW to 100 mW) sensor dependent

  • Dynamic Range: 50 dB in 10 dB steps Resolution: 0.01 dB in logarithmic mode, 0.1% of full scale in linear mode.

  • Auto Filter: The meter automatically selects the required number of averages for the selected range.

  • Accuracy Instrumentation: ±0.02 dB or ±5%

  • Zero Set (digital settability of zero): ±5% of full scale on most sensitive range. Decrease percentage by a factor of 10 for each higher range, ±1 display count.

 
Agilent / HP 5371A Agilent/HP 5371A Frequency and Time Interval Analyzer Contact Sales
Agilent/HP 5371A Frequency and Time Interval Analyzer

 

Agilent/HP 5371A Frequency and Time Interval Analyzer

Rent me for $300 a month

 

The Agilent 5371A frequency and time interval analyzer is a general-purpose modulation domain analyzer that captures frequency or time intervals at extremely high speeds. The 5371A combines a choice of over 60 arming and triggering configurations with built-in analysis including math, statistics, and limit testing. The 5371A uses a continuous measurement time sampling technique to quickly capture and display data. By eliminating reset time, measurement throughput is dramatically increased to more than 10 million measurements per second with a frequency range of up to 500 MHz. The 5371A can analyze jitter effects, characterize the transient and steady state responses of a VCO, examine frequency or phase modulation, measure frequency stability, analyze computer peripherals, or measure fast hopping radio signals.
 

Features

  • Calculated Allan Variance specifies frequency stability in the time domain
  • Broad selection of measurements
  • Quick and easy-to-use push button analysis
  • Graphic display and histograms add visual meaning to numbers
  • Excellent single-shot 10-digit resolution at 150 ps rms
  • Fast HP-IB throughput with up to 20,000 measurements per second
  • Calculated Allan Variance Many applications specify frequency stability by Allan Variance.
  • Allan and Root Allan Variances are calculated and displayed directly, along with traditional statistical parameters.
  • Frequency to 500 MHz is measured with zero dead time, assuring no lost information in the Allan Variance calculation.
  • Broad selection Measurements include frequency and period; time interval, +/- time interval, and continuous time interval; positive or negative pulse width; rise or fall time; duty cycle; totalize; phase; and peak amplitude.
  • Quick and easy Built-in statistics and analysis mean that you do not have to send data to a computer or write analysis software. 
 
Datachron 3170 Datachron 3170 IRIQ Time Code Generator Contact Sales
Datachron 3170 IRIQ Time Code Generator

 

Datachron 3170 IRIQ Time Code Generator

Rent me for $100 a month

   The Model 3170 Time Code Generator accumulates time from either an internal oscillator or an external frequency standard. When equipped with its synchronized generator option, the unit has two modes of operation; Generator and Synchronized Generator. In the Generator mode, time is presettable from the front panel and controls are provided to synchronize the unit to an external time standard such as WWV. Internal batteries maintain time accumulation for in excess of eight hours in the event of primary power failure. In the Synchronized Generator mode, the unit automatically synchronizes to a serial time code input such as IRIG B. The standard output of the unit is the IRIG B serial time code.

Optional outputs include

  • Parallel BCD outputs (tenths of milliseconds through days)

  • Parallel Binary Outputs (several ranges and resolutions available)

  • IEEE488 In/Out

  • RS232C In/Out

  • Pulse Rate Outputs

  • Sine Wave Outputs

  • Modem Rate Outputs

  • Other Time Code Outputs: IRIG A, E, G, H

  • NASA 36 and 28

  • AMR B1 and D5

  • XR3/2137

  • Multiple Rate Slow Code Output for strip chart recording.

   The unit accumulates time from an internal temperature compensated crystal oscillator (TCXO) or external 1MHz frequency standard as selected by internal jumpering.

Specifications for the TCXO are

  • Frequency: 1MHz

  • Stability: ±1 x 10-6 from 0 to +50°C

  • Aging Rate: 3 x 10-9 per day (5 X 10-7 per year)

  • Specifications for the 1MHz input are:

  • Waveform: Sine or square wave

  • Amplitude: 0.5 to 9 volts, peak to peak

  • Input Impedance: 10K ohms

   The Model 3170 operates from a primary power source of 115 volts AC ±10%, 50-70 Hz and consumes less than 20 watts of power. In the event of primary power failure, internal Nickel Cadmium batteries maintain time accumulation for in excess of eight hours. No display or outputs are provided during power failure. The batteries are continuously trickle charged when AC power is present.

 

 
Agilent / HP 5315B HP 5315B ,Universal Counter Contact Sales
100MHz UNIVERSAL COUNTER, SEVEN DIGITS/SEC RESOLUTION FROM 1Hz TO 100MHz, 100NS TIME INTERVAL, 10PS TIME INTERVAL TIME AVERAGING. PERIOD A ALLOWS SINGLE PERIODS VIA A CHANNEL, RATIO A/B, A GATED BY B, TOTALISE. SIGNAL CONDITIONED FOR BOTH CHANNELS.
 
Agilent / HP 5328B HP 5328B ,Universal Counter Contact Sales
100MHz UNIVERSAL COUNTER, SINGLE SHOT TIME INTERVAL 10NS TO 115 DAYS,TIME INTERVAL AVERAGING TO 10PS RESOLUTION, PERIOD AVERAGE, TOTALIZING, SCALE, RATIO, BURST & CW MSMTS, CAN BE USED WITH HP 5363B TIME INTERVAL PROBE. ARMED MSMTS CAPABLE AND HIGH PER. M
 
Instek GFC-8010H New Instek GFC-8010H 120Mhz $180.00
New Page 1

 

New Instek GFC-8010H 120 Mhz Frequency Counter with 2 year warranty

 

Display Resolution

  • Display 8 digits with Hz, kHz, MHz, GHz, S, mS, µS, nS and overflow 
  • Gate Time 0.1S, 1S, 10S switch selectable 
  • Accuracy +(1 digit + Timebase accuracy) 

Input Specifications

  • Sensitivity 10Hz ~ 60MHz < 20mVrms
  • 60MHz ~ 100MHz < 30mVrms
  • 100MHz ~ 120MHz < 40mVrms 
  • Impedance 1Mohm 35pF 
  • Coupling System AC Coupling 
  • Max Input Voltage 150Vrms 


Time Base Specifications

  • Oscillation Frequency 10MHz 
  • Aging Rate +1 ppm per month 
  • Temp. Stability 25°C + 5°C
  • Resolution The maximum resolution for frequency measurement is 100nHz for 1Hz and 0.1Hz for 100MHz input respectively, and for period measurement is 10nS for 1Hz and 0.1fS (f=10-15) for 100MHz input respectively. 
  • Power Source AC 100V/120V/220V/230V ±10%, 50/60Hz 

 

Supplied Accesories

  • Instruction manual
  • Power cord 
  • Test Lead GTL-101
  • Dimensions & Weight 230(W) × 95(H) × 280(D) mm, Approx. 1.7kg
 
Instek GFC-8131H New Instek GFC-8131H 1.3 Ghz $275.00
New Page 1

 

New Instek GFC-8131H 1.3 Ghz Frequency Counter with 2 year warranty

 

Display Resolution

  • Display 8 digits with Hz, kHz, MHz, GHz, S, mS, µS, nS and overflow 
  • Gate Time 0.1S, 1S, 10S switch selectable 
  • Accuracy +(1 digit + Timebase accuracy) 

Input Specifications Channel A

  • Range DC coupled 0.01Hz ~ 120MHz, AC coupled 30Hz ~ 120MHz 
  • Sensitivity 10mVrms typical, 50mVrms max 
  • Coupling AC or DC switchable 
  • Filter Low pass, switchable in or out for channel A.-3dB point of nominally 100kHz 
  • Impedance 1Mohm 40pF 
  • Attenuator x 20dB 
  • Trigger Level Adjustment -2.5 VDC to +2.5 VDC 
  • Resolution The maximum resolution for frequency measurement is 100nHz for 1Hz and 0.1Hz for 100MHz input respectively, and for period measurement is 10nS for 1Hz and 0.1fS (f=10-15) for 100MHz input respectively.
  • At least 7,6,5 digits are display for 1S, 100mS, 10mS gate time respectively 
  • Period Range 8nS to 100S at least 7 digits displayed for per second of gate time 

Input Specifications Channel B

  • Range 50MHz to 1.3GHz 
  • Sensitivity <40mVrms (10mVrms typical) 
  • Coupling AC only 


Time Base Specifications

  • Oscillation Frequency 10MHz 
  • Aging Rate +1 ppm per month 
  • Temp. Stability 25°C + 5°C
  • Resolution The maximum resolution for frequency measurement is 100nHz for 1Hz and 0.1Hz for 100MHz input respectively, and for period measurement is 10nS for 1Hz and 0.1fS (f=10-15) for 100MHz input respectively. 
  • Power Source AC 100V/120V/220V/230V ±10%, 50/60Hz 

 

Supplied Accesories

  • Instruction manual
  • Power cord 
  • Test Lead GTL-101
  • Dimensions & Weight 230(W) × 95(H) × 280(D) mm, Approx. 1.7kg



 
Instek GFC-8270H New Instek GFC-8270H 2.7 Ghz $375.00

New Instek 2.7 Ghz counter with 2 year warranty

  •  Frequency and Period measurement
  • Microprocessor controlled intelligent counter
  • High resolution at both high and low frequency
  • 0.01Hz ~ 2.7GHz frequency range
  • 10mVrms High sensitivity
  • 100nHz resolution for 1Hz
  • Self diagnosis routine
  • Variable Trigger Level control
  • Display hold function
Specifications
Display 8 digits with Hz, kHz, MHz, GHz, S, mS, µS, nS and overflow
Gate Time
Continuously vary from 10mS to 10S, or 1 period of input depending on whichever is greater
Accuracy
+(Resolution +Timebase error)
Channel A  Range DC coupled 0.01Hz ~ 120MHz?GAC coupled 30Hz ~ 120MHz 
Sensitivity
10mVrms typical?G 50mVrms max 
Coupling
AC or DC switchable 
Filter
Low pass, switchable in or out for channel A.-3dB point of nominally 100kHz 
Impedance
1M?¶//40pF 
Attenuator
x 20dB 
Trigger Level Adjustment
-2.5 VDC to +2.5 VDC 
Resolution
The maximum resolution for frequency measurement is 100nHz for 1Hz and 0.1Hz for 100MHz input respectively, and for period measurement is 10nS for 1Hz and 0.1fS (f=10-15) for 100MHz input respectively. At least 7,6,5 digits are display for 1S, 100mS, 10mS gate time respectively 
Period Range
8nS to 100S at least 7 digits displayed for per second of gate time
Channel B  Range 50MHz to 2.7GHz 
Sensitivity
<50mVrms (10mVrms typical) 
Coupling
AC only
Time Base 
Aging Rate
1 ppm, per Month 
Temperature
5 ppm 23°C + 5°C 
Line Variation
+0.005 ppm for +10% variation
Power Source AC 100V/120V/220V/240V ±10%, 50/60Hz
Accessories Instruction manual × 1,
Power cord × 1,

Dimensions & Weight 230(W) × 95(H) × 280(D) mm, Approx. 2.2kg

 
Madell FC-2700 New Madell FC-2700 2.7 Ghz Frequency Counter $180.00

 

New Madell FC-2700 2.7 Ghz Frequency Counter

 

Specifications
Model FC2700 FC1000
Frequency range 1~2700MHz 1~1000MHz
Display 8 digits LED
Gate 0.01S,0.1S,1S,10S
Precision 1Hz
Sensitivity 0-10MHz, 1-mV, 10Hz-100MHz, 25mV
100MHz-2700MHz, 25mV 100MHz-1000Mhz, 25mV
Input Impedance 1MΩ channel A,B, 50Ω channel C
Max input voltage 150V rms channel A,B, 5V rms channel C
Max aging rate 5ppm/year
Dimension 210x230x76mm

 

 
Reed FC-2500 New Reed FC-2500 2.5 GHz Frequency Counter $374.00
New Reed FC-2500 2.5 GHz Frequency Counter

 

New Reed FC-2500 2.5 GHz Frequency Counter

Microprocessor frequency counter measures to 2.5 GHz. Why pay more?

Features

  • High sensitivity in low/high ranges
  • Max, Min & Average readings
  • Relative frequency measurements
  • Large 0.5? 8-digit LCD display
  • Period display values from 10Hz to 10MHz
  • Data Hold; Auto power off; Overload indication
  • Gate time selector (Fast/Slow sampling time)


Specifications

  • Range (Frequency): Channel A: 50 MHz to 2500MHz, Channel B: 10 MHz to 500 MHz, Channel C: 10 Hz to 10MHz, Period: 10 Hz to 10 MHz
  • Maximum Resolution: 0.1 Hz
  • Sensitivity: Channel A, B, C: < 50 mV rms
  • Input Impedance: Channel A & B: 50Ω typical, Channel C: 1MΩ/30pF typical, AC coupled
  • Max. O/L Protection: 5V peak to peak, Channel C: 250V peak to peak
  • Time Base Circuit: 4.194 MHz quartz crystal
  • Connector: BNC
 
Tektronix 11302A Tek 11302A 500 MHz Analog Mainframe ( Lights, but no trace ), , Counter, Timer, O-Scope Contact Sales
6CM/NS WRITING SPEED, GPIB-RS232 , opt. 1T, with: 11A71 Amp SINGLE CHANNEL VERTICAL AMPLIFIER PLUG-IN 10MV/DIV SENS & 50 OHM INPUT IMPEDANCE CAN REACH 400MHz BW 11A32 2-Channel Amp DUAL TRACE VERTICAL AMPLIFIER PLUG-IN 1MV/DIV SENS, 50 OHM/1M OHM INPUT IM
 
Tektronix CMC251 Tektronix CMC251 ,1.3 GHz Frequency Counter Contact Sales
Slight chunk out of the plastic, but good shape otherwise - (Unit Only), , The CMC251 1.3 GHz Multifunction Counter measures the frequency of sine, square and triangle waves from 1 Hz to 1.3 GHz. The CMC251 also provides period, totalize and pulse width m
 
XL Microwave/ Pendulum 3620 XL Microwave/Pendulum Model 3620 26.5 GHz Frequency Counter Contact Sales
XL Microwave/Pendulum Model 3620 26.5 GHz Frequency Counter

 

XL Microwave/Pendulum Model 3620 26.5 GHz Frequency Counter

Rent me for $200 a month

   For bench and test systems applications like R&D, Service, incoming inspection, quality control and manufacturing test of RF components, systems or subassemblies, microwave transmitters/receivers, radar equipment etc, the models in the 3620-series gives you ultra-high performance and remote GPIB connectivity. Three instruments in one: Measurements are accurate and fast, with less than 60 ms acquisition time. With the Rubidium oscillator option, you will not only get a high-accuracy microwave counter, but also a 10 MHz reference output frequency for the local lab or for the ATE-rack, where you can supply other instruments with an atomic frequency standard. In Test Systems you save valuable space by integrating three instruments in one package; a mm frequency counter, a power meter and a frequency reference.

Features

  • Simultaneous Frequency and Power measurements

  • Wide frequency range from 10 Hz to 26.5 GHz

  • Compact, portable, rugged and battery operated

  • High stability Oven-controlled Crystal timebases and ultra-stable Rubidium option

  • Short acquisition time (<60ms)

  • Outstanding performance/price ratio

  The 3620-series of microwave counters provides simultaneous measurement of both frequency and power and are well suited for field, lab-bench, and test-rack environments. For field applications like installation, maintenance and calibration of microwave links, radar CW, microwave transmitters, DAB or DTV links, satellite ground stations or radio base stations, the models in the 3620-series give you ultra-high accuracy in a portable compact, lightweight and rugged design. A weather-resistant instrument back-pack is included with the battery power option.

   Very Easy to Use: To eliminate operator mistakes, the instruments are very easy to use and require no costly training. The front panel controls are self-explanatory and the read-out of result is unambiguous due to the bright LED display which ensures full visibility, whether in full sunlight or in low light.

 



Test Equipment, test eqipment, test and measurement, US INSTRUMENT SERVICES, rental, sales, used, HP, Hewlett Packard, Tektronix, tektronics, TEK, CSI, Campbell, oscilloscopes, ossiliscopes, optical, fiberoptic, Telecom, test sets, network, logic, B&K, Bruel, Kjaer, Dranetz, Telecom, TTC, Wandel, Goltermann, spectrum analyzers, logic analyzers, digital, multimeters, counters, data acquisition, HiPot, meggers, ground testing, protocol, pirateracing, butch


©1999-2002 [fill in company name] All Rights Reserved contact webmaster | powered by corezon
All logos and trademarks are properties of their respective companies. Product price, specification, warranty and availability subject to change without notice.