HTML Content Started Here
************************************************************
--%>
Category : Meters

|
|
Mfg. Name |
Mfg. Part# |
Product |
Unit Price |
Add To Cart |
| |
| |
AEMC
|
Clamp-on Ground Tester
|
AEMC 3730 Clamp-on Ground Tester
|
$1,795.00
|
|
|
AEMC Model 3730 Ground Tester
AEMC Model 3730 Ground Tester
Rent me for $250 a month
- Simple and fast
clamp-on operation - no leads, no auxilliary rods or spacing requirements
- Direct reading of
ground resistance from 1 to 1200 ohms
- Direct reading of
continuity and ground loop resistance
- Direct reading of
ground leakage current from 1 mA to 30 Arms
- New jaw design with
large 32 mm (1.25") window accommodates up to 1000 MCM cables
- Alarm function
- Memory function
The Ground Resistance
Tester Model 3730 measures ground rod and small grid resistance through any
season, without the use of auxiliary ground rods.
Clamp-on ground resistance testers are used in multi-grounded systems without
disconnecting the ground under test. The Models 3710 and 3730 simply clamp
around the ground conductor or rod and measure the resistance to ground. By
performing measurements on intact ground systems, the user also verifies the
quality of the grounding connections and bonds. Resistance and continuity of
grounding loops around pads and buildings may also be measured.
|
| |
| |
Agilent / HP
|
4349A
|
Agilent 4349A 4-Channel High Resistance Meter
|
$1,995.00
|
|
|
Agilent 4349A 4-Channel High Resistance Meter
Rent Me for $250 a month
The 4349A high resistance meter is a precise, reliable, high-speed test tool for
making precision high resistance measurements. The 4349A model offers
simultaneous 4-channel high resistance measurements for increased test
throughput.
Features and Specifications
- Auto and manual ranging
- Test voltage: External source required
- R range: 10 kohms to 1.0 x10 to the 15th ohms
- I range: 1 pA to 100 µA
- Input/output resistance: 1 kohm
- Basic accuracy: 2%
- Display resolution: 3 / 4 / 5 digits
- Measurement time: 9.5 mS / 28 mS / 98 mS / 397 mS
- Test cable length: 2 m max.
- Parameters measured: R, I
- HP-IB and handler interfaces
- 90-132/198-264 Vac; 47-66 Hz operation
- Weight: 15 lb; Size: 100 mm (3.94 in)H x 320 mm (12.6 in)W x 450 mm
(17.72 in)D
Measurement Range/Accuracy
| Parameter |
Measurement Range |
Basic Accuracy |
| I |
1 pA to 100 µA |
±0.4% |
| R (ohm) |
1 x 103 to 1.6 x 1016 |
±0.6% |
Measurement Time: 9 ms,
28 ms, 98 ms, 396 ms (typical)
Correction Function: Zero OPEN
Other Functions: Comparator Function;
Contact Check Function; Save/recall; Continuous Memory Capability; HP-IB
Interface; Handler Interface
PLEASE NOTE!
- Requires external voltage source for resistance
measurements
|
| |
| |
Agilent / HP
|
8903B
|
Agilent 8903B Audio Analyzer
|
$1,500.00
|
|
|
Agilent/HP 8903B Audio Analyzer Agilent/HP 8903B Audio AnalyzerRent me for $150 a month Different Filter options available please call
The Agilent/HP 8903B audio analyzer provides unparalleled versatility and performance for audio measurements from 20 Hz to 100 kHz. The Agilent/HP 8903B combines the functionality of a low-distortion audio source, high-performance
distortion analyzer, frequency counter, ac voltmeter, dc voltmeter, and SINAD meter into one compact package. With microprocessor control of source and analyzer, the Agilent/HP 8903B can perform stimulus-response measurements (such as signal-to-noise ratio and swept distortion) automatically with no additional equipment. For ease of use, most measurements on the Agilent/HP 8903B are made with only one or two keystrokes. The Agilent/HP 8903B automatically tunes and autoranges for maximum accuracy and resolution. For quick identification of input signals, the analyzer counts and displays the input frequency in all ac measurement modes. The standard Agilent/HP 8903B comes with 30 kHz and 80 kHz low-pass filters only. Two slots can accept any of the 6 optional filters Features. * 20 Hz to 100 kHz * Measures distortion, SINAD, signal to noise, True RMS Volts, DC Volts, and frequency * Built-in low distortion source * HP-IB
Internal Plug-In Filter Options Two band-limiting low-pass filters are standard. Optional high-pass and weighting filters can be fitted to match your requirements. The 8903B has two plug-in filter positions which can be loaded with any of six optional filters. The standard 8903B comes with no plug-in filters. You must order the appropriate filter options if you wish to have any of the filters listed below. Each filter option ordered adds additional cost to the instrument.
Filters Left Right 400 Hz High-pass 010 050 CCITT weighting filter 011 051 CCIR weighting filter 012 052 C-Message weighting filter 013 053 CCIR/ARM weighting filter 014 054 “A” weighting filter 015 055
FrequencyRange:
20 Hz to 100 kHzResolution: 0.3%Accuracy: 0.3% of settingOutput LevelRange: 0.6 mV to 6 V open circuitResolution: 0.3% or betterAccuracy:- 2% of setting 60 mV to 6 V, 20 Hz to 50 kHz.
- 3% of setting 6 mV to 6 V, 20 Hz to 100 kHz.
- 5% of setting 0.6 mV to 6 mV, 20 kHz to 100 kHz.
Flatness (1 kHz reference):- ±0.7% (±0.06 dB), 20 Hz to 20 kHz.
- ±2.5% (±0.22 dB), 20 Hz to 100 kHz.
|
| |
| |
Agilent / HP
|
4329A
|
Agilent HP 4329A High Resistance Meter
|
$500.00
|
|
|
Agilent/ HP 4329A High Resistance Meter
Agilent/ HP 4329A High Resistance Meter
Rent me for $100 a month
The Agilent/HP 4329A High Resistance Meter is a solid-state
insulation resistance meter designed for easy, accurate and direct readings of
the very high resistance values typically found in synthetic resins, porcelain,
insulating oils and similar materials. It is also useful for measurements in
electrical components like capacitors, transformers, switches and cables.
The Agilent/HP 4329A, is a solid state
insulation resistance meter designed for easy, accurate and direct readings of
the very high resistance values typically found in synthetic resins, porcelain,
insulating oils and similar materials. It is also useful for measurements in
electrical components such as capacitors, transformers, switches and cables.
Seven fully regulated DC test voltages (between 10 and 1000 Vdc) are provided as
test sources. The 4329A is also instantly convertible from ungrounded to
grounded sample operation via a simple relocation on the front panel ground
strap from "guard" to "+" position
Features
- Measures 500 kOhms to 2 x 10e-16 Ohms
- Selectable test voltages 10 V to 1000 V
- Current ranges from 5 x 10e-14 A to 2 x 10e-5 A
- Measure currents as low as 0.05 pA
- Analog meter
|
| |
| |
Agilent / HP
|
34401A
|
Agilent/HP 34401A 6.5 Digit Multimeter
|
$995.00
|
|
|
Agilent/HP 34401A 6.5 Digit Multimeter
Agilent/HP 34401A Multimeter
Rent me for $150 a month
Uncompromising Performance for Benchtop and System Testing
Product Overview
The Agilent 34401A multimeter is a tool kit of useful testing functions, from
min/max/avg to built-in limit testing. Getting accuracy in a digital multimeter
used to mean spending big. Not anymore. We will give you 6.5 digit precision
measurements for the price you would pay for 5.5 digits from other instrument
suppliers. Not only will you catch details that hide from other DMMs, you will
measure all day long with confidence (its 24-hour dc voltage accuracy is
0.0015%). And you get more than just great performance.
?Measure up to 1000 volts with 61/2 digits resolution
?0.0015% basic dcV accuracy (24 hour)
?0.06% basic acV accuracy (1 year)
?3Hz to 300kHz ac bandwidth
?1000 readings/sec. direct to GPIB
Superior performance
The Agilent Technologies 34401A multimeter gives you the
performance you need for fast, accurate bench and system testing. The 34401A
provides a combination of resolution, accuracy and speed that rivals DMMs
costing many times more. 61⁄2-digits of resolution, 0.0015% basic 24-hr dcV
accuracy and 1,000 readings/sec direct to GPIB assure you of results that are
accurate, fast, and repeatable.
Use it on your benchtop
The 34401A was designed with your bench needs in mind. Functions
commonly associated with bench operation, like continuity and diode test, are
built in. A Null feature allows you to remove lead resistance and other fixed
offsets in your measurements. Other capabilities like min/max/avg readouts and
direct dB and dBm measurements make checkout with the 34401A faster and easier.
The 34401A gives you the ability to store up to 512 readings in internal memory.
For trouble-shooting, a reading hold feature lets you concentrate on placing
your test leads without having to constantly glance at the display.
Use it for systems testing
For systems use, the 34401A gives you faster bus throughput than
any other DMM in its class. The 34401A can send up to 1,000 readings/sec
directly across GPIB in user-friendly ASCII format. You also get both GPIB and
RS-232 interfaces as standard features. Voltmeter Complete and External Trigger
signals are provided so you can synchronize to other instruments in your test
system. In addition, a TTL output indicates Pass/Fail results when limit testing
is used. To ensure both forward and backward compatibility, the 34401A includes
three command languages (SCPI, Agilent 3478A and Fluke 8840A /42A), so you
don?t have to rewrite your existing test software. An optional rack mount kit
is available.
|
| |
| |
Agilent / HP
|
3400A
|
Agilent/HP 3400A RMS Voltmeter
|
$399.00
|
|
|
New Page 1
Agilent/HP 3400A RMS Analog Voltmeter
Rent me for $100 a month
Please see our listing for the Instek GVT-417B. It is close on
most specs and a great deal at the price.
The Agilent/HP 3400A is a true root-mean-square (rms) voltmeter, providing a
meter indication proportional to the DC heating power of the input waveform.
Wide frequency response makes the Agilent/HP 3400A extremely flexible for all
audio and many RF measurements. Permits the accurate measurement of broadband
noise and fast rise pulses.
Features
- 10 Hz to 10 MHz bandwidth
- Thermal RMS converter
- 1 mV sensitivity
- Accurate with high crest factor and complex waveforms
- Analog meter
|
| |
| |
Agilent / HP
|
34411A
|
Agilent/HP 34411A High Performance 6 1/2 Digit Multimeter
|
Contact Sales
|
|
|
Agilent/HP 34411A High Performance 6 1/2 Digit Multimeter Agilent/HP 34411A High Performance 6 1/2 Digit Multimeter Rent me for $200 a month All the features of the 34410A plus- 50,000 readings/sec. @ 4 1/2 digits to the PC
- 1M reading memory
- Analog level and pre/post triggering
The Agilent 34410A is a high performance digital multimeter designed for high speed and precise triggering, offering maximum versatility for present and future needs. The 34410A is a 6½ digit, dual display, benchtop and Agilent Open digital multimeter featuring 10,000 readings per second at 5½ digits, datalogging wizard, resistance and frequency, and added LAN, USB and GPIB connectivity. If you need up to 50,000 readings/second, consider the 34411A Digital Multimeter, 6 1/2 Digit Enhanced Performance. Features- 6½ digit resolution
- 10,000 readings/sec @ 5 1/2 digits to the PC
- LAN, USB & GPIB standard
- Capacitance & temperature measurements
- Data logger for improved usability
- 50,000 reading non-volatile memory
- LXI Class C Compliant
The Best Just Got Better The Agilent 34410A and 34411A 61/2-Digit DMMs represent the latest generation of multimeters from Agilent Technologies. Building on the phenomenal success of the industry-standard Agilent 34401A, these new meters offer improved accuracy, expanded measurement capability, dramatically improved measurement speed and throughput, and modern computer interfaces including LAN and USB. The dual display offers both dual measurement capabilities and ease of use when setting up and configuring the DMM. Improvements have been made in every facet of the 34401A to make the best even better, whether you use it on the bench or in a system. Enhanced Measurement Performance The 34410A and 34411A offer Temperature and Capacitance capabilities, in addition to those measurements you have come to expect, such as DCV, ACV, DCI, ACI, 2-wire and 4-wire Resistance, Frequency, Period, Continuity and Diode Test. You also get Offset Compensated Ohms, allowing you to accurately measure resistance in the presence of voltages. Measurement ranges have been expanded as well; for example, DC and AC Current Ranges now go down to 100 ìA, resulting in 100 pA resolution. Real-time math and statistics are included, and a peak-detect capability allows you to capture peaks as short as 20 ìs. Modern I/O for Improved Connectivity When connecting to a computer, select LAN, USB or GPIB interfaces; all three are standard on the 34410A and 34411A. Concerned about the viability of your existing software programs? These new DMMs respond to Standard Commands for Programmable Instrumentation (SCPI), and there is even a 34401A Emulation Mode to ensure the easiest upgrade possible. Agilent?s I/O Library Suite ships with the 34410A and 34411A to help you quickly establish an error-free connection between your PC and instrument. It provides robust instrument control and works with the software development environment you choose. |
| |
| |
Agilent / HP
|
3458A
|
Agilent/HP 3458A 8.5 Digit Digital Multimeter with option 2
|
$7,500.00
|
|
|
Agilent/HP 3458A 8.5 Digit Digital Multimeter with option 2
Agilent/HP 3458A 8.5 Digit
Digital Multimeter
with option 2
Rent me for $500 a month
with option 2
High Stability (4
ppm/year) Reference
The Agilent 3458A Multimeter shatters long-standing performance barriers of
speed and accuracy on the production test floor, in R&D, and in the calibration
lab. The Agilent 3458A is simply the fastest, most flexible, and most accurate
multimeter ever offered by Agilent Technologies. In your system or on the bench,
the Agilent 3458A saves you time and money with unprecedented test system
throughput and accuracy, seven function measurement flexibility, and low cost of
ownership. Select a reading rate of 100,000 readings per second for maximal test
throughput. Or achieve highest levels of precision with up to 8.5 digits of
measurement resolution and 0.1 part per million transfer accuracy. Add this to
the Agilent 3458A's simplicity of operation, and you have the ideal multimeter
for your most demanding applications.
Features
- Math/statistics
- 20 kB memory
- Self-adjusting autocalibration
- dc Volts
- 100 mV to 1000 V ranges
- 10 nV sensitivity
- 0.05 ppm transfer accuracy
- ac Volts
- 10mV to 1000V ranges
- Analog, random and subsampled modes
- 0.002 ppm transfer accuracy
- Ohms
- 10 Ohms to 1 GOhm ranges
- 2- and 4-wire with offset compensation
The 3458A Multimeter performs a complete
self-calibration of all functions, including ac, using high stability internal
standards. This self- or autocalibration eliminates measurement errors due to
time drift and temperature changes in your rack or on your bench for superior
accuracy. When it?s time for periodic calibration to external standards, simply
connect a precision 10 Vdc source and a precision 10 kΩ resistor. All ranges and
functions, including ac, are automatically calibrated using precision internal
ratio transfer measurements relative to the external standards.
|
| |
| |
Agilent / HP
|
3458A
|
Agilent/HP 3458A Multimeter
|
$6,500.00
|
|
|
Agilent 3458A 8.5 Digit Digital Multimeter
Agilent 3458A 8.5 Digit Digital
Multimeter
Rent me for $400 a month
The Agilent 3458A Multimeter shatters long-standing performance barriers
of speed and accuracy on the production test floor, in R&D, and in the
calibration lab. The Agilent 3458A is simply the fastest, most flexible, and
most accurate multimeter ever offered by Agilent Technologies. In your system
or on the bench, the Agilent 3458A saves you time and money with unprecedented
test system throughput and accuracy, seven function measurement flexibility,
and low cost of ownership. Select a reading rate of 100,000 readings per second
for maximal test throughput. Or achieve highest levels of precision with up to
8.5 digits of measurement resolution and 0.1 part per million transfer
accuracy. Add this to the Agilent 3458A's simplicity of operation, and you have
the ideal multimeter for your most demanding applications.
Features
- Math/statistics
- 20 kB memory
- Self-adjusting autocalibration
- dc Volts
- 100 mV to 1000 V ranges
- 10 nV sensitivity
- 0.05 ppm transfer accuracy
- ac Volts
- 10mV to 1000V ranges
- Analog, random and subsampled modes
- 0.002 ppm transfer accuracy
- Ohms
- 10 Ohms to 1 GOhm ranges
- 2- and 4-wire with offset compensation
|
| |
| |
Agilent / HP
|
3468A
|
Agilent/HP 3468A Digital Multimeter
|
$499.00
|
|
|
New Page 1
Agilent/HP 3468A
5-1/2 Digit Digital Multimeter
with
HP-IL interface
Description
-
The HP Agilent 3468A is a Digital Multimeter that has 5 functions with
selectable 5 1/2, 4 1/2, or 3 1/2 digit resolution.
-
DC and true RMS AC voltage measurements are provided from 0.3 V full scale
range with 1uV sensitivity up to 300 V.
-
Bandwidth of the true RMS AC converter is from 20Hz to 100kHz on all ranges
and up to 300kHz on the 30 V range.
-
Either 2 or 4-wire ohms measurements can be selected with a maximum range of
30 Mohms.
-
Both DC and true RMS AC current capability is provided up to 3 Amps.
One outstanding feature of the Agilent/HP 3468A meter is the complete calibration is
done electronically, either manually from the front-panel of remotely in an
automatic calibration system. There are NO INTERNAL ADJUSTMENTS, complete
calibration of all functions can be done without removal of covers! HP-IL
(simple 2-wire interface) allows for full programmability
Functions of the 3468A
- DC / AC voltage
- DC / AC current, and resistance
- 0.3V to 300V DC / AC voltage range
- 1µV min. DC / AC voltage resolution
- 3A DC current
- 10µA DC current resolution
- 0.3A to 3A AC current range
- 1µA min. AC current resolution
- 300 ohm to 30Mohm resistance range
- 1 mohm min. resistance resolution
;
|
| |
| |
Agilent / HP
|
3586B
|
Agilent/HP 3586B Selective Level Meter
|
Contact Sales
|
|
|
New Page 1
Agilent/HP 3586B Selective Level Meter
The 3586A Selective Level Meter meets North American (Bell) requirements and
is fully programmable over the HP-IB. The unit provides a unique combination of
features, including wideband power. Its wide frequency coverage allows
measurements to be made at both voice channel and carrier frequencies.
Microprocessor control adds many ease-of-use features such as amplitude offset
measurements of tome and noise level in units of dBmO, dBrnCO, or dBpWO.
Convenience features include simultaneous analog and digital level displays,
precise frequency setting with HP's fractional N synthesized local oscillator,
accurate frequency counter and tone measurements with automatic channel
alignment for 1004Hz test tone or carrier frequency reference. Manufacturer's
Options Option 001 = 75 Ohm Connector mates with WECO 358A and 124 ohm Connector
mates with WECO 372A
Features
- Simultaneous analog and digital level displays
- Precise frequency setting with HP's fractional N synthesized local
oscillator
- Accurate frequency counter and tone measurements with automatic
channel alignment for 1004Hz test tone or carrier frequency reference.
|
| |
| |
Agilent / HP
|
4140B
|
Agilent/HP 4140B pA Meter and DC Voltage Source
|
Contact Sales
|
|
|
Agilent/HP 4140B pA Meter and DC Voltage Source Agilent/HP 4140B pA Meter and DC Voltage Source Rent me for $400 a month
The Agilent/HP 4140B Picoammeter / DC Voltage Source, consists of an extremely stable picoampere meter and two programmable DC Voltage sources, one of which operates as a ramp and staircase generator as well as a DC Source. These features make the 4140B ideal for making DC characteristic measurements such as leakage current, current-voltage characteristics and quasi-static C-V measurements required by the semiconductor industry for new product development and for improving production yields. Features - 3 basic semiconductor measurements: I, I-V and quasi-static C-V
- Two programmable voltage sources
- High resolution: 0.001 x 10-12 A
- HP-IB standard
- Stable pA Measurements
* maximum resolution of 10-15 mA * low noise test leads, and an electrostatic and light shielded test fixture - Synchronized I-V Measurements
* precise, programmable timing capability, we can now make fast, accurate I-V and C-V measurements - Quasi-Static C-V Measurements
* automatic quasi-static C-V measurements are easily accomplished by the ramp voltage capability - HP-IB Capability
Specifications - Measurement Functions: I, I-V and C-V
- Voltage Sources: two separate sources (VA and VB)
VA: ± 100V programmable source/function generator VB: ± 100V programmable dc voltage source
Current Measurements - Displays: current, 3½ digits with 2 character annunciator. Voltage, 3½ digits
- Measurement range: ±0.001 x 10-12 A to 1.000 x 10-2 A full scale in 11 ranges
- Overrange capability: 99.9% on all ranges
- Range selection: auto (lowest current range is selectable) and manual
- Zero Offset: cancels leakage current of test leads or test fixtures
- Offset range: 0 to ± 100 x 10-15 A
- Trigger: INT, EXT and HOLD/MAN
- Input terminal: triaxial
Capacitance-Voltage (C-V) Measurement - Measurement ranges: 0.0 pF - 100.0 pF and 200 pF - 1000 pF full scale in two ranges; 99.9% overrange
- Ranging: auto
- % C: capacitance change of device under test is displayed as a percent of the set value of the oxide capacitance (Cox = 100%)
- %C range: 0.0% - 199.9%
- Cox setting ranges (2 ranges): 0.1 pF - 199.9 pF and 200 pF - 1999 pF
- Zero offset: cancels stray capacitance of test fixtures and test leads
- Offset range: 0 to 100 pF
- High speed I data output: available with HP-IB interface only. Outputs current measurement data at 4 ms intervals (max rate)
DC Voltage Sources - Voltage ranges (VA and VB): 0 to ± 10.00V and 0 to ± 100.0V in 2 ranges, auto range only
- Maximum current: 10 mA, both sources
- Voltage sweep: auto and manual (pause), up/down step in manual (pause) mode. Sweep abort standard
Operating Parameter Setting Ranges - Start voltage and stop voltage: 0 - ± 10.00V, 0.01V steps; 0 - ± 100.0V, 0.1V steps
- Step voltage: 0 - ± 10.00V, 0.01V steps; 0 - ± 100.0V, 0.1V steps
- Hold time: 0 - 199.9 seconds in 0.1s increments; 0 - 1999 seconds in 1.0s increments
|
| |
| |
Biddle / AVO
|
210400
|
Biddle 210400 5 Kilovolt Megaohmmeter
|
Contact Sales
|
|
|
Biddle 210400 5 Kilovolt Megaohmmeter
Biddle 210400 5 Kilovolt Megaohmmeter
Rent me for $400 a month
The Biddle 210400 5 Kilovolt Megohmmeter is a
high-voltage, line-operated instrument. It provides a continuously variable test
voltage for highly sensitive insulation-resistance measurements of all types of
electrical equipment and power cable. The instrument is designed to withstand
harsh field conditions, and feature tough, impact-resistance casing, removable
lids and adjustable carrying straps. For complete portability, there is ample
room in its case to store cables and the instruction manual. The Biddle 210400 5
Kilovolt Megohmmeter measures up to 100,000 M ohms; provides output from 250
volts to 5 kV, with direct reading up to 50,000 M ohms at 2.5 kV.
Features
- Provides 2% kV and megaohm accuracy Guard terminal
to eliminate surface leakage current from the measurement
- Zero-start, high-voltage interlock
- Shielded, high-voltage output cable permanently
connected to the instrument
- Circuit-breaker protection
- Redundant grounding connections
- Easy-to-follow, color-coded meter scales
- Analog metering for monitoring of variable
measurements
- Rugged field construction Input Voltage 120
Vac, 60 Hz
-
Test Voltage 0 to 5 kVdc, negative with respect to ground
-
Output Current 5 mA continuous
-
Short-Circuit Current 12 mA max.
Kilovoltmeter
-
4.5-in. (114-mm) taut band
-
Three Color-Coded Scales
-
Red: 0 to 2.5 kV
-
Black: 0 to 5 kV
-
Green: 0 to 1 reference
-
Accuracy: ±2% full scale
Megohmmeter
-
4.5-in. (114-mm) taut band
-
Two Color-Coded Scales
-
Red: 0.5 to 50 M½
-
Black: 1 to 100 M½
-
Accuracy: ±0.031 in. (0.08 cm) at any marking
Operating Temperature Range 0 to 122º F (?17.7 to +50º C)
|
| |
| |
Coaxial Dynamics
|
98958A
|
Coaxial Dynamics 98958A High Power Wattmeter
|
$559.00
|
|
|
Coaxial Dynamics 98958A High Power Wattmeter
Coaxial Dynamics 98958A High Power
Wattmeter
Available for leases please call
Requires additional Digital Broadcast Elements to fit your application.
Typical cost is $394.
Features
- Shock Mounted "Taut Band" Meter
- 4-1/2" Mirrored Scale
- Uses Gold Plated Digital Plug-In Elements
- Two Year Limited Warranty
- Measures up to 100,000 watts depending upon element selected
- 15/30/60 Scale
The Coaxial Dynamics High-Power Digital Wattmeters are designed
for the accurate measurement of complex RF Waveforms such as CDMA (Code Division
Multiple Access), DAB (Digital Audio Broadcast), DTV (Digital TV) and HDTV (High
Definition TV), as well as CW, AM and FM. To use the Wattmeter, simply connect
it between the power source and antenna or dummy load and plug in the
appropriate measuring element. The RF power is directly displayed on the 4-1/2"
triple scale meter. Several different models are available with either 5/10/25
scales or 15/30/60 scales. The external Line Section can be used up to 200-feet
from the meter with the permanently attached DC cables (10-foot normally
supplied). The meter unit is protected by a rugged, shock-proof housing. For
added convenience, two sockets for storage of additional measuring elements are
located on the back of the unit. The use of a rugged shock mounted meter with a
mirror-backed scale along with superior taut band technology, provides reliable
and accurate readings, and also satisfies both the US Navy and Canadian
standards for bounce and vibration. This is your assurance of complete accuracy.
Your confidence in the quality and dependability of these High-Power Digital
Wattmeters is assured with the Coaxial Dynamics Two Year Limited Warranty.
|
| |
| |
Fluke
|
45
|
Fluke 45 Dual Display Multimeter
|
$595.00
|
|
|
New Page 1
Fluke 45 Dual Display
Multimeter
with 10 Amp Range
Rent me for $100 a month
Maximum Versatility In a Single
Instrument
The Fluke 45 is a feature-rich 5-digit, 100 000
count meter that truly fits all applications and virtually any measurement need
_ on the workbench or in the field. Two multifunction displays and 16 different
measurement capabilities allow wide ranging versatility at an affordable price.
The Fluke 45 delivers high performance and flexibility for manufacturing test,
depot and field service, as well as R&D applications.
- Multifunction vacuum fluorescent dual display allowing the user to
measure two different parameters of the same signal from one test
connection, and view both measurements at the same time.
- True-rms voltage and current, including ac + dc
- RS-232 interface standard, IEEE-488.2 option
- Frequency measurement to 1 MHz
- dB measurements: 21 selectable reference impedances. From 2 to 8000,
and audio power from 2Ω to 16Ω
- Compare (Hi/Lo/Pass) function for quick in-tolerance tests
- 0.05% dc current accuracy for 4-20 mA current loop service
- Closed-Case Calibration: Calibration can be performed via the RS-232
(or optional IEE-488.2) interface or manually from the front panel. No
internal adjustments are required
- Optional FlukeView Forms, accessory software package; allows quick
set-up and effortless communication between the Fluke 45 and an IBM PC or
compatible. Custom forms are easily created, saved, and recalled
|
|
| |
| |
Fluke
|
5790A
|
Fluke 5790A AC Measurement Standard with wideband option
|
Contact Sales
|
|
|
Fluke 5790A AC Measurement Standard with wideband option Fluke 5790A AC Measurement Standard with wideband option Rent me for $3000 a month with option
Automated AC measurement with precision that is easy to use The 5790A is a complete automated ac measurement standard designed for the most demanding calibration applications. It combines the accuracy you would expect from a thermal transfer standard with the ease-of-use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ±24 ppm (one year, 23oC ±5oC). The 5790A is designed to meet the complete ac voltage and wideband verification requirements of the Fluke 5700A, 5500A and other calibrators, amplifiers like the 5725A and 5205A, and transfer standards and ac voltmeters. The 5790A covers an alternating voltage range of 700 µV to 1000V, and a frequency range of 10 Hz to 1 MHz. A wideband voltage option extends frequency range to 30 MHz to meet the calibration requirements of Fluke 5700A, 5720A and 5100 Series Wideband Options. The 5790A is also compatible with Fluke A40 and A40A Current Shunts, which permit you to make ac/dc current transfer measurements up to 20A. The 5790A may be used alone or as a transfer standard with an external dc source. In either case the normally tedious switching and calculations are performed automatically by the 5790A, and the resulting ac/dc difference is displayed directly on the easy-to-read vacuum fluorescent display. Versatility that keeps you productive When you first power up the 5790A, diagnostics verify the instrument's integrity. The variety of input connections allows you to use the one that best suits your application. There are four sets of input terminals on the 5790A, two Type-N connectors and two sets of five-way binding posts. One Type-N and one set of binding posts are dedicated to the ac measurement and transfer modes. AC or dc voltages may be applied to either input connection over the 5790's full range, allowing you to perform automated ac/dc transfer measurements. The 5790A determines automatically whether the applied voltage is ac or dc. The second Type-N input connection supports the optional wideband mode, and the second set of binding posts are designed for Fluke A40 Series Current Shunts. The input connection is selected with the touch of a key on the 5790A front panel. An LED indicates which selection is active. |
| |
| |
Fluke
|
8012A
|
Fluke 8012A Digital MultiMeter
|
$100.00
|
|
|
3-1/2 DIGIT DIGITAL MULTIMETER , DCV 200MV-1000V, TRMS ACV 200MV-750V RESOLUTION 100UV ON LOWEST RANGE DC CURRENT 200UA-2MA AC CURRENT 200UA-2000MA RESOLUTION 0.1UA ON LOWEST RANGE RESISTANCE 2 OHMS-2000 kOHMS CONDUCTANCE 2MS-200NS |
| |
| |
Fluke
|
8050A
|
Fluke 8050A 4 1/2 Digit Digital Multimeter
|
Contact Sales
|
|
|
Fluke 8050A 4 1/2 Digit Digital Multimeter
Fluke 8050A 4 1/2 Digit Digital Multimeter
The Fluke Model 8050A is a portable bench-type digital multimeter (DMM) with
a 4-1/2 digit liquid crystal display (LCD). It is an industry legend for a
long term accuracy, reliability and overload protection. The 8050A has all the
following industry-standard features
-
Voltage measurements from 10uV to 1000V dc and 10mV to 750V true-rms ac
- Current measurements from 10mA to 2A dc and 10uA to 2A true-rms ac
- Resistance measurements from 10M Ohm to 20M Ohm
The Fluke 8050A also has several special measurement features. These special
features include the following:
-
Conductance measurements up to 100,000M Ohm
- Voltage measurements in decibels, that can be referenced to 1 of 16 user
selected reference impedances
- Resistance ranges that supply enough voltage to turn on a PN junction to
allow diodes and transistors to be tested
- The ability to store any input signal as an offset or relative reference
value
- Automatic polarity indication and overrange indication
- Protection from overloads and protection from transients of up to 6 kV, 10
microseconds
- Dual-slope integration a/d conversion to ensure noise-free measurements
- Long term calibration stability (1 year)
|
| |
| |
Fluke
|
8508A
|
Fluke 8508A 8.5 Digit Reference Multimeter
|
Contact Sales
|
|
|
Fluke 8508A 8.5 Digit Reference Multimeter
Fluke 8508A 8.5 Digit Reference Multimeter
Rent me for $1000 a month
with option
- 001 Reference
Multimeter with front and rear binding posts and ratio measurement package
Reference standard accuracy and stability, in one
functionally versatile, easy to use solution
The Fluke 8508A is an 8.5-digit
resolution instrument designed specifically for metrologists. With superior
accuracy and stability over a wide range of measurements the 8508A is designed
to serve as a versatile precision measurement tool for calibration laboratories
that must meet increasingly stringent measurement uncertainty analysis
requirements demanded by ISO 17025, as well as the need for increased
productivity.
With the introduction of the 8508A,
Fluke has created a new product category ? the reference multimeter ?
specifically for metrology applications. The 8508A Reference Multimeter draws
upon decades of Fluke expertise.
The 8508A features 8.5 digit resolution, exceptional linearity
and extraordinarily low noise and stability, producing what are arguably the
most accurate measurements to be had from any commercially available product
today. That?s why stability must be
treated with the same priority as accuracy. The 8508A demonstrates 365 day
stability as low as 2.7 ppm, with a 24 hour stability of 0.5 ppm, ensuring that
confidence in today?s measurement can be the same as it was yesterday or last
year.
To achieve this frequently requires a complex array of
instruments. The Fluke 8508A provides an extraordinarily broad range of
measurement capability. This means you can undertake a wider range of
applications, and perform most of your measurement requirements with a single
instrument.
Voltage measurement
With DC and AC ranges from 200 mV to
1 kV, the 8508A covers all your voltage measurement needs. Full 8.5 digit
resolution is available on all ranges to provide resolution down to 1 nV.
Bandwidth for AC measurements extends to 1 MHz. Excellent linearity, coupled
with Ratio measurement capability, means that the 8508A can replace Kelvin
Varley dividers and AC/DC voltage transfer standards.
Current measurements
The 8508A features a remarkable new
current measurement system. For the first time, resistance at the input is
virtually zero. This means that measurements can be much less invasive.
Resistance measurement
With ranges from 2 Ω to 20 GΩ and resolution as low as
10 nΩ, the 8508A can truly be described as the ultimate resistance
measurement system.
|
| |
| |
Fluke
|
8922A
|
Fluke 8922A True RMS AC Voltmeter
|
Contact Sales
|
|
|
Fluke 8922A True RMS AC Voltmeter
Fluke 8922A True RMS AC Voltmeter
Rent me for $100 a month
The Fluke 8922A True-RMS Digital Voltmeter has bandwidth
capabilities for many applications, from testing high-frequency oscillators,
attenuator flatness and amplifier frequency response to microphone levels, phono-pickup
devices, vibration tests and wideband noise levels - to list a few. The 8922A
offers low-frequency capabilities in the 2 Hz to 11 MHz bandwidth and a
switchable 200 kHz low pass filter which eliminates unwanted high-frequency
noise from the measured signal.
Features
- 2 Hz to 11MHz bandwidth
- 4 digit display
- Autoranging
- BNC input
- Analog display for peak/null adjustments
- Frequency Range: 2 mV - 20V range = 2 Hz to 11
MHz and 200V - 700V range = 2 Hz to 1 MHz
- Ranges: 2mV, 20mV, 200mV, 2V, 20V, 200V, and
700V
- Low Pass Filter: 200 kHz
- Maximum Input: 700V rms or 1000V peak
- Response Time:
- AC: 1.6 seconds
- AC + DC: 7 seconds
- Input Impedance: 10 MW/
shunted by by <30 pF
- Resolution: 0.05% of range
- dB Range: 132 dB
- dB Resolution: 0.01 dB
- Input: Isolated BNC input floating up to .6V
peak
|
| |
| |
Fluke
|
97
|
Fluke 97 50 Mhz Scopemeter
|
Contact Sales
|
|
|
Fluke 97 50 Mhz Scopemeter
Fluke 97 50 Mhz Scopemeter
Rent me for $100 a month
The Fluke 97 Scopemeter is the
benchmark tester for everything that came after it. A two channel oscilloscope
and built in multimeter provide a wealth of useful troubleshooting information.
Powerful, portable and accuracy in a small hand held unit.
Specifications
- Bandwidth: 50 MHz Dual Channel
- Sample Rate: 25 Megasamples/second
- Autoset: Automatically sets Voltage, Time & Trigger
- Multimeter Display: 3 2/3 Digits (> 3000 Counts)
- True RMS Volts: AC or AC+DC up to 600V (1700V Pk-Pk)
- Resistance: 30 ohm to 30 Mohm
- Diode Test: up to 2.8V
- Continuity Beeper
- Time/Division: 10 ns/div to 60 sec/div
- Volts/Division: 1 mV/div to 100 V/div
- Digital Delay or Pre-Trigger: By Number of Cycles, Events, Time or Zoom
Mode
- Special Multimeter Modes: Min Max Average Record with Time Stamp, Relative
(zero), dBm, dBV, dBW, Audio Watts, %Scale, Frequency, %Duty Cycle, Smoothing?,
Change Alert?
- Oscilloscope Cursors: 15 Measurements, Display 5 Simultaneously
- Glitch Capture: >40 ns
- Waveform Processing: Average, Min Max, Record, Variable Persistence
- Waveform Memory: Store & Recall 8 Waveforms
- Set-up Memory: Store & Recall 10 Front Panel Set-Ups
- Waveform Mathematics: Add, Subtract, Multiply, Invert, Filter or Integrate
Waveforms
- Signal Generator Output: Sine wave or Square wave
- Component Tester Output: voltage or current ramp
- Size: 2.4" H x 5.1" W x 10.2" L
- Weight: 3.3 lbs
|
| |
| |
Agilent / HP
|
3403C
|
HP 3403C ,True RMS Voltmeter
|
Contact Sales
|
|
|
3-1/2 digit true RMS voltmeter, useable from DC to 100 MHz 10mv (AC only) to 1000v. Selectable slow (2hz-100mhz) or fast (25Hz to 100 MHA) response. Slow response time: 10s fast response time :1s, , Option 1, recorder output Unit and info card only |
| |
| |
Agilent / HP
|
3478A
|
HP 3478A Digital Multimeter
|
Contact Sales
|
|
|
3.5 to 5.5 digit DMM , DCV 30mv-300v, resistance 30 Ohms-30mOhms DC current 300ma-3a AC voltage 300mv-300v AC current 300ma-3a Autoranging, sensitivity 100 nanovolts HP-IB |
| |
| |
Agilent / HP
|
400EL
|
HP 400EL AC Voltmeter
|
Contact Sales
|
|
|
Linear db scale, -10 to + 2db, 10Hz-10 MHz Log voltage scale 1mv-300v fs |
| |
| |
Keithley
|
195A
|
Keithley 195A Digital Multimeter
|
$299.00
|
|
|
Keithley 195A Digital Multimeter
Keithley 195A
Digital Multimeter
The Keithley 195A
Multimeter is a fully programmable GPIB instrument with a 5 1/2 digit
resolution multimeter with 0.01% dc volt accuracy and 0.015% resistance
accuracy. . In a standard configuration it is capable of reading between 100 nV
and 1000 volts DC. It can measure up to 700 volts AC and up to 2 amps AC or DC
with option 1950. A great meter for the price. This is much more than a simple
voltmeter. Keithley is legendary for stability and accuracy of measurement
results.
|
| |
| |
Keithley
|
196
|
Keithley 196 System DMM
|
$995.00
|
|
|
Keithley
196 System Digital Multimeter
Keithly builds
excellent high quality products with unmatched service and
support. Keithly products meet their specifications.
The Keithley Model 196 System DMM is a five function autoranging~
digital multimeter. At 6 1/2 digit resolution, the LED display can
display +-3,030,000 counts. The range of this analog-to-digital (A/D)
converter is greater than the normal l,999,999 A/D converter used in
many 6 1/2 digit DMMs. The built-in IEEE-488~ interface makes the
instrument fully programmable over the IEEE-488 bus. The Model 196 can
make the following basic measurements:
1. DC voltage measurements from lOOnV to 3OOV.
2. Resistance measurements from lOO uohm to 3OOMegaohm
3. TRMS AC voltage measurements from 1pV to 300V.
4. DC current me&urements from lnA to 3A.
5. TRMS AC current measurements from lnA to 3A.
Some important Model 196 features include:
* 10 Character Alphanumeric Display-Easy to read 14segment LEDs used
for readings and front panel messages.
*High Speed Measurement Rate-l000 readings per second.
* Zero-Used to cancel offsets or establish baselines. A zero value can
be programmed from the front panel or over the IEEE-488 bus.
* Filter-The weighted average digital filter can be set from the front
panel or over the bus.
* Data Store-Can store up to 500 readings and is accessible only over
the bus.
* Digital Calibration-The instrument may be digitally calibrated from
either the front panel or over the bus.
* User Programmable Default Condition Any instrument measurement
configuration can be established as the power-up default conditions.
* Translator Software-User defined words (stored in nonvolatile memory)
can be used to replace standard command strings over the IEEE-488 bus.
* Offset Compensated Ohms-Used to correct for small error voltages in
the measurement circuit.
|
| |
| |
Keithley
|
197
|
Keithley 197 5 1/2-Digit Portable Multimeter
|
Contact Sales
|
|
|
Keithley 197 5 1⁄2-Digit Portable Multimeter
Keithley 197 5 1⁄2-Digit Portable Multimeter The Model 197 is a lightweight, portable DMM with a battery pack option. It combines 51⁄2-digit resolution (on a 220,000-count display) with 1µV, 1nA, 1mΩ sensitivity. Basic DCV accuracy is 0.011%. Extended Performance Measure voltage over nine decades from 1µV to 1000V. Input resistance on the two lowest voltage ranges exceeds 1GΩ. TRMS AC measurements can be made to 100kHz. Make 2- or 4-terminal ohms measurements over 11 decades from 1mΩ to 220MΩ. Six current ranges measure from 1nA to 10A. Battery Option The Model 1978 battery pack option enables data to be collected in locations where AC power is not available or where isolation from line voltage is required for safety. Features ? 1µV, 1mΩ, 1nA sensitivity ? TRMS AC measurements to 100kHz ? 100-point data logger, relative reference, dB ? Backlit display ? Battery option
DISPLAY: Backlit ±220,000-count LCD, 0.45 in height; polarity,function, range, and status indication. RELATIVE: Pushbutton allows zeroing of on range readings. Allows readings to be made with respect to baseline value.Front panel annunciator indicates REL mode. DATA LOGGER and MIN/MAX: 100 reading storage capacity; records data at one of six selectable rates from 3 readings/second to 1 reading/hour or by manual triggering. Also detects and stores maximum and minimum readings continuously while in data logger mode. CONVERSION RATE: 3 readings/second. OVERRANGE INDICATION: ?OL? displayed. ENVIRONMENT: Operating: 0°?50°C; <80% relative humidity up to 35°C; linearly derate 3% RH/°C, 35°?50°C. Storage: ?40° to +70°C. WARM?UP: 1 hour to rated accuracy.
Question: What is the difference between a 197 and 197A? Answer: 197A is Light gray color, 197 is dark brown color 197A has Detachable line cord, 197 line cord is permanent 197A has Back lit display, 197 is not 197A was more efficient for longer battery life than the 197 197A is still supported by Repair (as of Sept 2003), 197 is no longer supported
|
| |
| |
Keithley
|
197A
|
Keithley 197A Multimeter
|
$795.00
|
|
|
Keithley 197A 5 1⁄2-Digit Portable Multimeter
Keithley 197A 5 1⁄2-Digit Portable Multimeter The Model 197A is a lightweight, portable DMM with a battery pack option. It combines 51⁄2-digit resolution (on a 220,000-count display) with 1µV, 1nA, 1mΩ sensitivity. Basic DCV accuracy is 0.011%. Extended Performance Measure voltage over nine decades from 1µV to 1000V. Input resistance on the two lowest voltage ranges exceeds 1GΩ. TRMS AC measurements can be made to 100kHz. Make 2- or 4-terminal ohms measurements over 11 decades from 1mΩ to 220MΩ. Six current ranges measure from 1nA to 10A. Battery Option The Model 1978 battery pack option enables data to be collected in locations where AC power is not available or where isolation from line voltage is required for safety. Features ? 1µV, 1mΩ, 1nA sensitivity ? TRMS AC measurements to 100kHz ? 100-point data logger, relative reference, dB ? Backlit display ? Battery option
DISPLAY: Backlit ±220,000-count LCD, 0.45 in height; polarity,function, range, and status indication. RELATIVE: Pushbutton allows zeroing of on range readings. Allows readings to be made with respect to baseline value.Front panel annunciator indicates REL mode. DATA LOGGER and MIN/MAX: 100 reading storage capacity; records data at one of six selectable rates from 3 readings/second to 1 reading/hour or by manual triggering. Also detects and stores maximum and minimum readings continuously while in data logger mode. CONVERSION RATE: 3 readings/second. OVERRANGE INDICATION: ?OL? displayed. ENVIRONMENT: Operating: 0°?50°C; <80% relative humidity up to 35°C; linearly derate 3% RH/°C, 35°?50°C. Storage: ?40° to +70°C. WARM?UP: 1 hour to rated accuracy.
Question: What is the difference between a 197 and 197A? Answer: 197A is Light gray color, 197 is dark brown color 197A has Detachable line cord, 197 line cord is permanent 197A has Back lit display, 197 is not 197A was more efficient for longer battery life than the 197 197A is still supported by Repair (as of Sept 2003), 197 is no longer supported
|
| |
| |
Keithley
|
2000-Scan
|
Keithley 2000-Scan Scanner Card
|
Contact Sales
|
|
|
New Page 1
Keithley 2000-Scan Scanner Card
Keithley has designed three plug-in scanner cards
for use with Model 2000, 2001, 2002, and 2010 DMMs. Simply by inserting the
appropriate card in the option slot on the DMM?s back panel, users can create
a multipoint test and measurement system that?s well suited to applications
involving up to ten measurement points. Combining scan and measurement
capabilities in a single instrument reduces the need for extra equipment,
eliminates complexities of triggering, timing, and processing issues, and helps
reduce test time significantly. Also, since the scanners were designed
specifically to work with these DMMs, measurement integrity is assured. For
larger ATE applications, the DMMs can be easily combined with Keithley?s 7000
Series switch matrices and cards for high-speed, high accuracy scanning and
measurement.
Model 2000-SCAN Scanner Card
? Ten analog input channels (2-pole)
? Configurable as 4-pole, 5-channel
Model 2000, 2001, 2002, and 2010 DMM users can
create an economical ten-channel data logger simply by inserting the Model
2000-SCAN scanner card into the DMM?s back panel option slot. Users can
multiplex one of ten 2-pole or one of five 4-pole signals into the Model 2000
and/or any combination of 2- or 4-pole signals. Contact potential is typically
less than 500nV per contact pair (1μV maximum) for high measurement
integrity.
GENERAL: 10 channels of 2-pole relay input. All channels
configurable to 4-pole.
CAPABILITIES: Multiplex one of ten 2-pole or one of five
4-pole signals into DMM.
INPUTS
Maximum Signal Level: DC Signals: 110V DC, 1A switched, 30VA
maximum (resistive load). AC Signals: 125V AC rms or 175V AC peak, 100kHz
maximum, 1A switched, 62.5VA maximum (resistive load).
Contact Life: >105 operations at maximum signal level;
>108 operations cold switching.
Contact Resistance: <1Ω at end of contact life.
Actuation Time: 2.5ms maximum on/off.
Contact Potential: <±500nV typical per contact, 1μV
max. <±500nV typical per contact pair, 1μV max.
Connector Type: Screw terminal, #22 AWG wire size.
Isolation Between Any Two Terminals: >109Ω,
<75pF.
Isolation Between Any Terminal and Earth: >109Ω,
<150pF.
Common Mode Voltage: 350V peak between any terminal and
earth.
Maximum Voltage Between Any Two Terminals: 200V peak.
Maximum Voltage Between Any Terminal and Model 2001 Input LO:
200V peak.
ENVIRONMENTAL: Meets all Model 2000 environmental
specifications.
DIMENSIONS: 21mm high × 72mm wide × 221mm deep (0.83
in. × 2.83 in. × 8.7 in.). Adds 0.4kg (10 oz.).
|
| |
| |
Keithley
|
2001
|
Keithley 2001 MultiMeter
|
$2,495.00
|
|
|
Keithley 2001 High-Performance 7-1/2-Digit DMM
Keithley 2001 High-Performance 7-1/2-Digit DMM
Rent me for $300 a month
Superior measurement speed and integrity
In addition to the wide range of measurement functions and
capabilities common to all Series 2000 DMMs, the Model 2001 has many other
advantages for test system builders. While other DMMs may claim to offer
71⁄2-digit resolution, they typically must average multiple readings to achieve
their specified resolution, which slows the reading rate significantly. In
contrast, the Model 2001’s true 71⁄2-digit resolution is based on a 28-bit
A-to-D converter, so no averaging is needed to discern smaller changes. This
high resolution also provides greater dynamic range, so it’s possible to measure
from 1µV to 20V on a single range and avoid range-shift errors.
Unique
measurement capabilities
Unlike the Model 2000 or 2010, the Model 2001 offers the
ability to make peak spikes measurements without the need for a separate
oscilloscope. Its internal peak detector can catch 1µs spikes, such as power
supply spikes and transients, AC line power surges, and short-duration drop outs
on components, as well as up to 1MHz for repetitive signals. The Model 2001 can
automatically display and store the highest value, or display the maximum and
minimum values of spikes. Similarly, no oscilloscope is required to determine if
the crest factor—the ratio of peak value to rms values—of an AC signal is
acceptable to ensure measurement accuracy, because the Model 2001 measures AC
crest factor directly. While some DMMs will calculate average AC from the RMS
value, these calculations apply only to sine wave inputs. With the Model 2001,
it’s easy to measure AC peak value, average, and true rms directly to
characterize the signal completely. This capability is ideal for AC circuit
design or test, and to verifying test voltages specified only in averages.
MEASUREMENT FUNCTIONS
• DCV • ACV (peak, avg. and rms) • AC+DCV
(peak, avg. and rms) • DCI • AC+DCI (peak, avg.
and rms) • ACI (peak, avg. and rms) • 2WΩ • 4WΩ
• Frequency • Period • dB, dBm • Crest factor
measurements • Peak spikes (high and low) • Time
stamp • DC in-circuit current • Temperature (TCs
and RTDs) • Lead resistance
|
| |
| |
Keithley
|
224
|
Keithley 224 Programmable Current Source
|
Contact Sales
|
|
|
Keithley 224 Programmable Current Source Keithley 224 Programmable Current Source Rent me for $200 a month
The Model 224 programmable current source was designed for general purpose bench or system use. The INCREMENT/DECREMENT function is manual or automatic, and selectable dwell times provide stepped ramp capabilities. The Model 2243 IEEE-488 option is field installable. It allows flexible programming including current, V-LIMIT, local lockout, service request masks, and serial polling. A digital I/O port on the IEEE-488 interface card provides four TTL compatible input and output lines. The status of the I/O port can be interrogated and changed over the bus. The AUTO function allows automatic incrementing or decrementing of the output. Time per step can be set from 50ms/step to 999.9s/step. In some applications, it is necessary to limit the voltage across the device under test. The Model 224 offers compliance limit settings ranging from ±1V to ±105V in 1V steps. An SRQ on V-LIMIT can be programmed if the 2243 IEEE-488 option is installed. A blinking LED indicates V-LIMIT or bench operation. Features - Display: 0.5 in LED digits, 4½-digit signed mantissa, 1-digit signed exponent
- Maximum Allowable Common Mode Voltage (Output or Output Common to Chassis): 250 V rms, DC to 60 Hz
- Increment/Decrement: automatic, manual or trigger modes
- Range of Dwell Times: 50 ms to 999.9 s
- Output Load: Output load must be non-inductive
- External Trigger: TTL-compatible External Trigger Input and Output
- Output Connections: Teflon® insulated 2-lug triax connector (specialty connector 30JR121-1) for output; five way binding posts for GUARD, OUTPUT COMMON and CHASSIS GROUND; BNC (chassis isolated) connectors for EXTERNAL TRIGGER INPUT and OUTPUT
- All connections on rear panel
General Information
- OVER VOLTAGE LIMIT INDICATION:
?VLIMIT? LED blinks.
SELF TEST: Digital RAM, ROM, & front panel LEDs at power ON. WARM-UP: 1 hour to rated accuracy. POWER: 105?125 or 210?250V AC (internal switch selected), 50 or 60Hz, 60W maximum (80VA maximum). 90?105 or 180?210V AC operation available. COOLING: Internal fan for forced air cooling. ENVIRONMENTAL LIMITS: Operating: 0°?50°C; up to 35°C at 70% non-condensing relative humidity. Storage: ?25° to 70°C. DIMENSIONS, WEIGHT: 127mm high ´ 216mm wide ´ 359mm deep (5 in ´ 81⁄2 in ´ 141⁄8 in). Net weight 4.5kg (9 lb 15 oz). |
| |
| |
Keithley
|
236
|
Keithley 236 Source Measurement Unit
|
$3,995.00
|
|
|
Keithley 236 Source Measurement Unit
Keithly 236 Source
Measurement Unit
Rent me for $500 a month
? Four
instruments in one (voltage source, voltage measure, current source, current
measure)
? 10fA, 10µV measurement sensitivity
? Standard and custom sweep capability including pulse
? 1000 source/measurements per second
? Four quadrant source operation
? Internal 1000-reading memory
The 236, Source-Measure Units (SMU) is a fully
programmable instrument, capable of sourcing and measuring voltage or current
simultaneously. These systems are really four instruments in one: voltage
source, current source, voltage measure, and current measure.
Applications
These instruments address a wide variety of
applications, including the characterization of semiconductor devices and the
measurement of leakage currents or insulation resistance. They are
particularly useful as source and measuring instruments in automated test
equipment (ATE).
Wide Dynamic Range
The Model 236 will source voltage from 100µV to 110V, and current
from 100fA to 100mA. It can also measure voltage from 10µV to 110V and
current from 10fA to 100mA.
Selectable Sweeps of Voltage and Current
The 236 can be programmed to perform source-measurements as a
function of a stepped voltage or current. Voltage and current can be swept
linearly, logarithmically, or pulsed. The START, STOP, STEP method of setting
sweep parameters allows operators to become proficient at using the instrument
very quickly. Sweep parameters may be appended (APPEND key) to obtain more
complex test sequences.
What is an electrometer?
Essentially, an electrometer is a highly refined digital
multimeter (DMM). Electrometers can be used for virtually any measurement task
that a conventional DMM can and offer the advantages of very high input
resistance when used as voltmeters, and ultra-low current sensitivity with low
voltage burden when used as ammeters. Electrometers are superior to DMMs by
three to eight orders of magnitude in these respects. That makes them the
instruments of choice for measuring voltages with high source impedance or
currents with low source impedance (i.e., signals from non-ideal sources).
Electrometers can also measure charge directly.
|
| |
| |
Keithley
|
2400
|
Keithley 2400 200 Volt 1 Amp Sourcemeter
|
$3,499.00
|
|
|
Keithley 2400 200 Volt 1 Amp Sourcemeter
Keithley 2400 200 Volt 1 Amp Sourcemeter
Rent me for $400 a month
The Power of Three
Instruments in One
The tightly
coupled nature of a SourceMeter instrument provides many advantages over
separate instruments. For example, it provides faster test times by reducing
GPIB traffic and simplifies the remote programming interface. It also protects
the device under test from damage due to accidental overloads, thermal runaway,
etc. Both the current and voltage source are programmable with readback to help
maximize device measurement integrity. If the readback reaches a programmed
compliance limit, then the source is clamped at the limit, providing fault
protection.
Keithley?s
SourceMeter family is designed specifically for test applications that demand
tightly coupled sourcing and measurement. All SourceMeter models provide
precision voltage and current sourcing as well as measurement capabilities. Each
SourceMeter instrument
is both a highly stable DC power source and a true instrument-grade 51⁄2-digit
multimeter. The power source characteristics include low noise, precision, and
readback. The multimeter capabilities include high repeatability and low noise.
The result is a compact, single-channel, DC parametric tester. In operation,
these instruments can act as a voltage source, a current source, a voltage
meter, a current meter, and an ohmmeter. Manufacturers of components and modules
for the communications, semiconductor, computer, automotive, and medical
industries will find the SourceMeter instruments invaluable for a wide range of
characterization and production test applications.
Advantages of a Tightly
Integrated Instrument
By linking
source and measurement circuitry in a single unit, these instruments offer a
variety of advantages over systems configured with separate source and
measurement instruments. For example, they minimize the time required for test
station development, setup, and maintenance, while lowering the overall cost of
system ownership. They simplify the test process itself by eliminating many of
the complex synchronization and connection issues associated with using multiple
instruments. And, their compact half-rack size conserves precious ?real
estate? in the test rack or bench.
|
| |
| |
Keithley
|
2400-LV
|
Keithley 2400-LV 20 Volt 1 Amp Sourcemeter
|
$3,499.00
|
|
|
Keithley 2400 200 Volt 1 Amp Sourcemeter
Keithley 2400-LV 20 Volt 1 Amp Sourcemeter
Has option LV to disable the 200 volt range
for sensitive device protection
Rent me for $400 a month
The Power of Three
Instruments in One
The tightly
coupled nature of a SourceMeter instrument provides many advantages over
separate instruments. For example, it provides faster test times by reducing
GPIB traffic and simplifies the remote programming interface. It also protects
the device under test from damage due to accidental overloads, thermal runaway,
etc. Both the current and voltage source are programmable with readback to help
maximize device measurement integrity. If the readback reaches a programmed
compliance limit, then the source is clamped at the limit, providing fault
protection.
Keithley?s
SourceMeter family is designed specifically for test applications that demand
tightly coupled sourcing and measurement. All SourceMeter models provide
precision voltage and current sourcing as well as measurement capabilities. Each
SourceMeter instrument is both a highly stable DC power source and a true
instrument-grade 51⁄2-digit multimeter. The power source characteristics
include low noise, precision, and readback. The multimeter capabilities include
high repeatability and low noise. The result is a compact, single-channel, DC
parametric tester. In operation, these instruments can act as a voltage source,
a current source, a voltage meter, a current meter, and an ohmmeter.
Manufacturers of components and modules for the communications, semiconductor,
computer, automotive, and medical industries will find the SourceMeter
instruments invaluable for a wide range of characterization and production test
applications.
Advantages of a Tightly
Integrated Instrument
By linking
source and measurement circuitry in a single unit, these instruments offer a
variety of advantages over systems configured with separate source and
measurement instruments. For example, they minimize the time required for test
station development, setup, and maintenance, while lowering the overall cost of
system ownership. They simplify the test process itself by eliminating many of
the complex synchronization and connection issues associated with using multiple
instruments. And, their compact half-rack size conserves precious ?real
estate? in the test rack or bench.
|
| |
| |
Keithley
|
428
|
Keithley 428 Current Amplifier with IEEE-488
|
Contact Sales
|
|
|
Keithley 428 Current Amplifier with IEEE-488 Keithley 428 Current Amplifier with IEEE-488 Rent me for $400 a month The Model 428-PROG Programmable Current Amplifier converts fast, small currents to a voltage, which can be easily digitized or displayed by an oscilloscope, waveform analyzer, or data acquisition system. It uses a sophisticated ?feedback current? circuit to achieve both fast rise times and sub-picoamp noise. The gain of the Model 428-PROG is adjustable in decade increments from 1 | | |