The Agilent/HP 5328A, thru the use of technology
such as a ROM controlled measurement cycle and a modular design,
provides you with excellent universal counter price/performance.
Optional modules allow you to tailor the performance of the 5328 A
to meet your particular measurement needs. In many instances,
however, the standard 5328A offers all the capability you're likely
to need.
Burst and CW measurements to 100 MHz: special gating
circuits start a measurement only when the input signal is present,
allowing burst frequencies to be measured as easily as CW signals.
The option 030 C Channel extends this capability to 512 MHz;
option 031, to 1300 MHz.
Single shot time interval measurements: the standard
universal module's 100 ns single shot resolution meets or exceeds
the requirements for a wide range of applications such as
mechanical and electromechanical device timing (relays), time of
flight measurements (ballistics), sonar ranging, radio ranging and
navigation.
Time interval averaging: resolution better than 10 ps
(10~n seconds) for repetitive time intervals as short as 100 ps
Display: 9 digit LED display, ninth digit used only with
channel C functions (FREQ. C, Ratio C/A, Events C,
A-*B). Blanking: suppresses display of unwanted
zeros to left of most significant digit.
Storage: holds reading between samples; can be overridden
by rear panel switch.
Sample rate: variable from less than 2 ms between
measurements to HOLD which holds display indefinitely.
Gate output: rear panel output, TTL levels; high if gate
is open.
Period, period average, ratio, totalize, scale: extra
problem solving power for your special requirements.
Armed measurements: versatile arming modes (controlled by
a rear panel switch) allow real time control over when a
measurement begins. Useful for measurements such as frequency burst
profile and frequency sweep linearity.
Trigger lights: trigger light blinks when channel is
triggering; light is ON when input is above trigger level; OFF when
input is below trigger level. Simplifies trigger level
adjustments.
High performance marker outputs: marker outputs
(operational to 100 MHz) indicate where channel is triggering in
real time for oscilloscope monitoring applications. Provides
measurement feedback to the operator for greatly simplified
measurement set-ups. These features and capabilities make the 5328A
an excellent choice for general purpose lab use, electronic
service, and production test. For more demanding applications, a
variety of options offer extended performance at a modest increase
in price.
Operating temperature: 0° to 50° C.
Power requirements: 100/120/220/240 V rms, +5%, -10%
(switch selectable), 48-66 Hz; 150 VA max