  The Agilent Technologies 83236B PCS Interface is a cellular to PCS frequency translator. When combined with Agilent Technologies TDMA and CDMA RF test sets, it provides PCS test solutions for your TDMA and CDMA PCS phones.

Features

  • 1710 to 1990 MHz frequency coverage
  • Serial interface bus for Agilent 8920B and Agilent 8924C
  • 8924E firmware control options
  • Fast CDMA power measurements

TDMA and CDMA Test Solutions

   The Agilent Technologies 83236B PCS Interface is a cellular to PCS frequency translator. When combined with Agilent Technologies TDMA and CDMA RF test sets, it provides PCS test solutions for your TDMA and CDMA PCS phones and cell sites. 83236B PCS-band test solutions build on the following successful 800 MHz test sets.

  • 8920B Option 800 TDMA Mobile Test Set
  • 8924C CDMA Mobile Station Service Test Set
  • 8924E CDMA Mobile Station Service Test Set

   For configuration information, refer to the Agilent 8920B Configuration Guide, pub. number 5968-5919E.

PCS-band Coverage

   The 83236B translates 800 MHz measurement capabilities to the 1710 to 1990 MHz frequency range. This frequency range covers the International (1710 to 1880 MHz), Korean (1715 to 1870 MHz), and North American (1850 to 1990 MHz) PCS bands.

Measurement Accuracy

   Power measurement accuracy and speed are maintained at PCS-band frequencies with an internal power meter for measurements on CW, CDMA, and TDMA (ยน/4 pulsed or continuous) signals.

Connectors

1. FROM DUPLEX OUT Input Impedance: 50 ohm (nominal) Connector Type: Type N (F) SWR: <1.3:1 Input Frequency Range: 810 MHz to 995 MHz Input Level Range: -70 dBm to -7 dBm

2. To ANT IN  Frequency Range: 650 MHz to 940 MHz Output Impedance: 50 ohm (nominal) Connector Type: Type N (F) SWR: <2.3:1

3. RF IN/OUT Input/Output Impedance: 50 own (nominal) Connector Type: Type N (F) SWR: <1.2:1 Applied Power: Subscriber Unit Test Single carrier TDMA and FM: 40 dBm (10 W) CDMA: 37 dBm (5 W) Base Station Test Single carrier TDMA and FM: 40 dBm (10 W) CDMA and multi-carrier: 30 dBm (1 W) Max Peak Instantaneous Signal: 30 V

4. RF OUT Only Output Impedance: 50 ohm (nominal) Connector Type: Type N (F) SWR: <1.6:1 Reverse Power Protection: 200 mW CW max

5. REF IN Input Frequency: 10 MHz Input Level Range: -5 dBm to +10 dBm Input Impedance: 50 ohm (nominal) Connector Type: BNC (F)

6. REF OUT  Output Frequency: 10 MHz Output Level: -1 dBm Output Impedance: 50 ohm (nominal) Connector Type: BNC (F)

7. EXT TRIG IN External Trigger Signal: (Required for TDMA RF input level range -13 dBm to -5 dBm) Input Level: TTL Input Impedance: >1 kohm at 1 MHz (nominal) Triggering Type: Positive edge Connector Type: SMC (M)

8. DET OUT: (Output for CDMA) Output Impedance: 50 ohm  (nominal) Connector Type: SMC (M)

 